Cargando…

Semi-automated carotid lumen segmentation in computed tomography angiography images

Carotid artery stenosis causes narrowing of carotid lumens and may lead to brain infarction. The purpose of this study was to develop a semi-automated method of segmenting vessel walls, surrounding tissues, and more importantly, the carotid artery lumen by contrast computed tomography angiography (C...

Descripción completa

Detalles Bibliográficos
Autores principales: Hemmati, Hamid Reza, Alizadeh, Mahdi, Kamali-Asl, Alireza, Shirani, Shapour
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Editorial Department of Journal of Biomedical Research 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6307665/
https://www.ncbi.nlm.nih.gov/pubmed/29109328
http://dx.doi.org/10.7555/JBR.31.20160107
Descripción
Sumario:Carotid artery stenosis causes narrowing of carotid lumens and may lead to brain infarction. The purpose of this study was to develop a semi-automated method of segmenting vessel walls, surrounding tissues, and more importantly, the carotid artery lumen by contrast computed tomography angiography (CTA) images and to define the severity of stenosis and present a three-dimensional model of the carotid for visual inspection.In vivo contrast CTA images of 14 patients (7 normal subjects and 7 patients undergoing endarterectomy) were analyzed using a multi-step segmentation algorithm. This method uses graph cut followed by watershed and Hessian based shortest path method in order to extract lumen boundary correctly without being corrupted in the presence of surrounding tissues. Quantitative measurements of the proposed method were compared with those of manual delineation by independent board-certified radiologists. The results were quantitatively evaluated using spatial overlap surface distance indices. A slightly strong match was shown in terms of dice similarity coefficient (DSC) = 0.87±0.08; mean surface distance (D(msd)) = 0.32±0.32; root mean squared surface distance (D(rmssd)) = 0.49±0.54 and maximum surface distance (D(max)) = 2.14±2.08 between manual and automated segmentation of common, internal and external carotid arteries, carotid bifurcation and stenotic artery, respectively. Quantitative measurements showed that the proposed method has high potential to segment the carotid lumen and is robust to the changes of the lumen diameter and the shape of the stenosis area at the bifurcation site. The proposed method for CTA images provides a fast and reliable tool to quantify the severity of carotid artery stenosis.