Evaluation of the Linear Relationship Between Pulse Arrival Time and Blood Pressure in ICU Patients: Potential and Limitations

A variety of techniques based on the indirect measurement of blood pressure (BP) by Pulse Transit Time (PTT) have been explored over the past few years. Such an approach has the potential in providing continuous and non-invasive beat to beat blood pressure without the use of a cuff. Pulse Arrival Ti...

Descripción completa

Detalles Bibliográficos
Autores principales: Escobar-Restrepo, Braiam, Torres-Villa, Robinson, Kyriacou, Panayiotis A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308183/
https://www.ncbi.nlm.nih.gov/pubmed/30622482
http://dx.doi.org/10.3389/fphys.2018.01848
_version_ 1783383138319204352
author Escobar-Restrepo, Braiam
Torres-Villa, Robinson
Kyriacou, Panayiotis A.
author_facet Escobar-Restrepo, Braiam
Torres-Villa, Robinson
Kyriacou, Panayiotis A.
author_sort Escobar-Restrepo, Braiam
collection PubMed
description A variety of techniques based on the indirect measurement of blood pressure (BP) by Pulse Transit Time (PTT) have been explored over the past few years. Such an approach has the potential in providing continuous and non-invasive beat to beat blood pressure without the use of a cuff. Pulse Arrival Time (PAT) which includes the cardiac pre-ejection period has been proposed as a surrogate of PTT, however, the balance between its questioned accuracy and measurement simplicity has yet to be established. The present work assessed the degree of linear relationship between PAT and blood pressure on 96 h of continuous electrocardiography and invasive radial blood pressure waveforms in a group of 11 young ICU patients. Participants were selected according to strict exclusion criteria including no use of vasoactive medications and presence of clinical conditions associated with cardiovascular diseases. The average range of variation for diastolic BP was 60 to 79 mmHg while systolic BP varied between 123 and 158 mmHg in the study database. The overall Pearson correlation coefficient for systolic and diastolic blood pressure was −0.5 and −0.42, respectively, while the mean absolute error was 3.9 and 7.6 mmHg. It was concluded that the utilization of PAT for the continuous non-invasive blood pressure estimation is rather limited according to the experimental setup, nonetheless the correlation coefficient performed better when the range of variation of blood pressure was high over periods of 30 min suggesting that PAT has the potential to be used as indicator of changes relating to hypertensive or hypotensive episodes.
format Online
Article
Text
id pubmed-6308183
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-63081832019-01-08 Evaluation of the Linear Relationship Between Pulse Arrival Time and Blood Pressure in ICU Patients: Potential and Limitations Escobar-Restrepo, Braiam Torres-Villa, Robinson Kyriacou, Panayiotis A. Front Physiol Physiology A variety of techniques based on the indirect measurement of blood pressure (BP) by Pulse Transit Time (PTT) have been explored over the past few years. Such an approach has the potential in providing continuous and non-invasive beat to beat blood pressure without the use of a cuff. Pulse Arrival Time (PAT) which includes the cardiac pre-ejection period has been proposed as a surrogate of PTT, however, the balance between its questioned accuracy and measurement simplicity has yet to be established. The present work assessed the degree of linear relationship between PAT and blood pressure on 96 h of continuous electrocardiography and invasive radial blood pressure waveforms in a group of 11 young ICU patients. Participants were selected according to strict exclusion criteria including no use of vasoactive medications and presence of clinical conditions associated with cardiovascular diseases. The average range of variation for diastolic BP was 60 to 79 mmHg while systolic BP varied between 123 and 158 mmHg in the study database. The overall Pearson correlation coefficient for systolic and diastolic blood pressure was −0.5 and −0.42, respectively, while the mean absolute error was 3.9 and 7.6 mmHg. It was concluded that the utilization of PAT for the continuous non-invasive blood pressure estimation is rather limited according to the experimental setup, nonetheless the correlation coefficient performed better when the range of variation of blood pressure was high over periods of 30 min suggesting that PAT has the potential to be used as indicator of changes relating to hypertensive or hypotensive episodes. Frontiers Media S.A. 2018-12-21 /pmc/articles/PMC6308183/ /pubmed/30622482 http://dx.doi.org/10.3389/fphys.2018.01848 Text en Copyright © 2018 Escobar-Restrepo, Torres-Villa and Kyriacou. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Escobar-Restrepo, Braiam
Torres-Villa, Robinson
Kyriacou, Panayiotis A.
Evaluation of the Linear Relationship Between Pulse Arrival Time and Blood Pressure in ICU Patients: Potential and Limitations
title Evaluation of the Linear Relationship Between Pulse Arrival Time and Blood Pressure in ICU Patients: Potential and Limitations
title_full Evaluation of the Linear Relationship Between Pulse Arrival Time and Blood Pressure in ICU Patients: Potential and Limitations
title_fullStr Evaluation of the Linear Relationship Between Pulse Arrival Time and Blood Pressure in ICU Patients: Potential and Limitations
title_full_unstemmed Evaluation of the Linear Relationship Between Pulse Arrival Time and Blood Pressure in ICU Patients: Potential and Limitations
title_short Evaluation of the Linear Relationship Between Pulse Arrival Time and Blood Pressure in ICU Patients: Potential and Limitations
title_sort evaluation of the linear relationship between pulse arrival time and blood pressure in icu patients: potential and limitations
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308183/
https://www.ncbi.nlm.nih.gov/pubmed/30622482
http://dx.doi.org/10.3389/fphys.2018.01848
work_keys_str_mv AT escobarrestrepobraiam evaluationofthelinearrelationshipbetweenpulsearrivaltimeandbloodpressureinicupatientspotentialandlimitations
AT torresvillarobinson evaluationofthelinearrelationshipbetweenpulsearrivaltimeandbloodpressureinicupatientspotentialandlimitations
AT kyriacoupanayiotisa evaluationofthelinearrelationshipbetweenpulsearrivaltimeandbloodpressureinicupatientspotentialandlimitations