High-Resolution Shear Wave Imaging of the Human Cornea Using a Dual-Element Transducer
Estimating the corneal elasticity can provide valuable information for corneal pathologies and treatments. Ophthalmologic pathologies will invariably cause changes to the elasticity of the cornea. For example, keratoconus and the phototoxic effects of ultraviolet radiation usually increase the corne...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308409/ https://www.ncbi.nlm.nih.gov/pubmed/30513950 http://dx.doi.org/10.3390/s18124244 |
_version_ | 1783383180751929344 |
---|---|
author | Chen, Pei-Yu Shih, Cho-Chiang Lin, Wei-Chen Ma, Teng Zhou, Qifa Shung, K. Kirk Huang, Chih-Chung |
author_facet | Chen, Pei-Yu Shih, Cho-Chiang Lin, Wei-Chen Ma, Teng Zhou, Qifa Shung, K. Kirk Huang, Chih-Chung |
author_sort | Chen, Pei-Yu |
collection | PubMed |
description | Estimating the corneal elasticity can provide valuable information for corneal pathologies and treatments. Ophthalmologic pathologies will invariably cause changes to the elasticity of the cornea. For example, keratoconus and the phototoxic effects of ultraviolet radiation usually increase the corneal elasticity. This makes a quantitative estimation of the elasticity of the human cornea important for ophthalmic diagnoses. The present study investigated the use of a proposed high-resolution shear wave imaging (HR-SWI) method based on a dual-element transducer (comprising an 8-MHz element for pushing and a 32-MHz element for imaging) for measuring the group shear wave velocity (GSWV) of the human cornea. An empirical Young’s modulus formula was used to accurately convert the GSWV to Young’s modulus. Four quantitative parameters, bias, resolution, contrast, and contrast-to-noise ratio (CNR), were measured in gelatin phantoms with two different concentrations (3% and 7%) to evaluate the performance of HR-SWI. The biases of gelatin phantoms (3% and 7%) were 5.88% and 0.78%, respectively. The contrast and CNR were 0.76, 1.31 and 3.22, 2.43 for the two-side and two-layer phantoms, respectively. The measured image resolutions of HR-SWI in the lateral and axial directions were 72 and 140 μm, respectively. The calculated phase SWV (PSWV) and their corresponding Young’s modulus from six human donors were 2.45 ± 0.48 m/s (1600 Hz) and 11.52 ± 7.81 kPa, respectively. All the experimental results validated the concept of HR-SWI and its ability for measuring the human corneal elasticity. |
format | Online Article Text |
id | pubmed-6308409 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-63084092019-01-04 High-Resolution Shear Wave Imaging of the Human Cornea Using a Dual-Element Transducer Chen, Pei-Yu Shih, Cho-Chiang Lin, Wei-Chen Ma, Teng Zhou, Qifa Shung, K. Kirk Huang, Chih-Chung Sensors (Basel) Article Estimating the corneal elasticity can provide valuable information for corneal pathologies and treatments. Ophthalmologic pathologies will invariably cause changes to the elasticity of the cornea. For example, keratoconus and the phototoxic effects of ultraviolet radiation usually increase the corneal elasticity. This makes a quantitative estimation of the elasticity of the human cornea important for ophthalmic diagnoses. The present study investigated the use of a proposed high-resolution shear wave imaging (HR-SWI) method based on a dual-element transducer (comprising an 8-MHz element for pushing and a 32-MHz element for imaging) for measuring the group shear wave velocity (GSWV) of the human cornea. An empirical Young’s modulus formula was used to accurately convert the GSWV to Young’s modulus. Four quantitative parameters, bias, resolution, contrast, and contrast-to-noise ratio (CNR), were measured in gelatin phantoms with two different concentrations (3% and 7%) to evaluate the performance of HR-SWI. The biases of gelatin phantoms (3% and 7%) were 5.88% and 0.78%, respectively. The contrast and CNR were 0.76, 1.31 and 3.22, 2.43 for the two-side and two-layer phantoms, respectively. The measured image resolutions of HR-SWI in the lateral and axial directions were 72 and 140 μm, respectively. The calculated phase SWV (PSWV) and their corresponding Young’s modulus from six human donors were 2.45 ± 0.48 m/s (1600 Hz) and 11.52 ± 7.81 kPa, respectively. All the experimental results validated the concept of HR-SWI and its ability for measuring the human corneal elasticity. MDPI 2018-12-03 /pmc/articles/PMC6308409/ /pubmed/30513950 http://dx.doi.org/10.3390/s18124244 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Chen, Pei-Yu Shih, Cho-Chiang Lin, Wei-Chen Ma, Teng Zhou, Qifa Shung, K. Kirk Huang, Chih-Chung High-Resolution Shear Wave Imaging of the Human Cornea Using a Dual-Element Transducer |
title | High-Resolution Shear Wave Imaging of the Human Cornea Using a Dual-Element Transducer |
title_full | High-Resolution Shear Wave Imaging of the Human Cornea Using a Dual-Element Transducer |
title_fullStr | High-Resolution Shear Wave Imaging of the Human Cornea Using a Dual-Element Transducer |
title_full_unstemmed | High-Resolution Shear Wave Imaging of the Human Cornea Using a Dual-Element Transducer |
title_short | High-Resolution Shear Wave Imaging of the Human Cornea Using a Dual-Element Transducer |
title_sort | high-resolution shear wave imaging of the human cornea using a dual-element transducer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308409/ https://www.ncbi.nlm.nih.gov/pubmed/30513950 http://dx.doi.org/10.3390/s18124244 |
work_keys_str_mv | AT chenpeiyu highresolutionshearwaveimagingofthehumancorneausingadualelementtransducer AT shihchochiang highresolutionshearwaveimagingofthehumancorneausingadualelementtransducer AT linweichen highresolutionshearwaveimagingofthehumancorneausingadualelementtransducer AT mateng highresolutionshearwaveimagingofthehumancorneausingadualelementtransducer AT zhouqifa highresolutionshearwaveimagingofthehumancorneausingadualelementtransducer AT shungkkirk highresolutionshearwaveimagingofthehumancorneausingadualelementtransducer AT huangchihchung highresolutionshearwaveimagingofthehumancorneausingadualelementtransducer |