Determination of Trace Amounts of Hydrofluoric Acid in Non-Aqueous Solutions by the Coulometric Titration Method

For monitoring of trace amounts of hydrofluoric acid in the organic fluorine chemical industry, a facile method for determination of the hydrofluoric acid in an ethanol solution of lithium chloride, by coulometric titration, was proposed. Relying on homemade acid–base coulometric autotitrator, the e...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Cairui, Shen, Congcong, Jin, Ling, Cai, Hongwei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308496/
https://www.ncbi.nlm.nih.gov/pubmed/30558266
http://dx.doi.org/10.3390/s18124439
_version_ 1783383202454306816
author Huang, Cairui
Shen, Congcong
Jin, Ling
Cai, Hongwei
author_facet Huang, Cairui
Shen, Congcong
Jin, Ling
Cai, Hongwei
author_sort Huang, Cairui
collection PubMed
description For monitoring of trace amounts of hydrofluoric acid in the organic fluorine chemical industry, a facile method for determination of the hydrofluoric acid in an ethanol solution of lithium chloride, by coulometric titration, was proposed. Relying on homemade acid–base coulometric autotitrator, the electrolyte was 0.50 mol·L(−1) LiCl ethanol solution and the constant current intensity was 0.2–2 mA. As for the working electrode pair, a platinum plate was used as a working electrode, and a platinum wire was used as an auxiliary electrode. The indicating electrode was the pH composite glass electrode and the titration endpoint was pH 5.50. The results showed that the relative standard deviation was below 2.0%, as the content of the hydrofluoric acid was between 2 μg to 100 μg. The recovery rate was 99.0–102.0%. This proposed route has the advantages of simplicity, convenience, quickness, accuracy, and automation, which can be applied to the accurate determination of trace amounts of hydrofluoric acid, in non-aqueous solutions.
format Online
Article
Text
id pubmed-6308496
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-63084962019-01-04 Determination of Trace Amounts of Hydrofluoric Acid in Non-Aqueous Solutions by the Coulometric Titration Method Huang, Cairui Shen, Congcong Jin, Ling Cai, Hongwei Sensors (Basel) Article For monitoring of trace amounts of hydrofluoric acid in the organic fluorine chemical industry, a facile method for determination of the hydrofluoric acid in an ethanol solution of lithium chloride, by coulometric titration, was proposed. Relying on homemade acid–base coulometric autotitrator, the electrolyte was 0.50 mol·L(−1) LiCl ethanol solution and the constant current intensity was 0.2–2 mA. As for the working electrode pair, a platinum plate was used as a working electrode, and a platinum wire was used as an auxiliary electrode. The indicating electrode was the pH composite glass electrode and the titration endpoint was pH 5.50. The results showed that the relative standard deviation was below 2.0%, as the content of the hydrofluoric acid was between 2 μg to 100 μg. The recovery rate was 99.0–102.0%. This proposed route has the advantages of simplicity, convenience, quickness, accuracy, and automation, which can be applied to the accurate determination of trace amounts of hydrofluoric acid, in non-aqueous solutions. MDPI 2018-12-15 /pmc/articles/PMC6308496/ /pubmed/30558266 http://dx.doi.org/10.3390/s18124439 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Huang, Cairui
Shen, Congcong
Jin, Ling
Cai, Hongwei
Determination of Trace Amounts of Hydrofluoric Acid in Non-Aqueous Solutions by the Coulometric Titration Method
title Determination of Trace Amounts of Hydrofluoric Acid in Non-Aqueous Solutions by the Coulometric Titration Method
title_full Determination of Trace Amounts of Hydrofluoric Acid in Non-Aqueous Solutions by the Coulometric Titration Method
title_fullStr Determination of Trace Amounts of Hydrofluoric Acid in Non-Aqueous Solutions by the Coulometric Titration Method
title_full_unstemmed Determination of Trace Amounts of Hydrofluoric Acid in Non-Aqueous Solutions by the Coulometric Titration Method
title_short Determination of Trace Amounts of Hydrofluoric Acid in Non-Aqueous Solutions by the Coulometric Titration Method
title_sort determination of trace amounts of hydrofluoric acid in non-aqueous solutions by the coulometric titration method
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308496/
https://www.ncbi.nlm.nih.gov/pubmed/30558266
http://dx.doi.org/10.3390/s18124439
work_keys_str_mv AT huangcairui determinationoftraceamountsofhydrofluoricacidinnonaqueoussolutionsbythecoulometrictitrationmethod
AT shencongcong determinationoftraceamountsofhydrofluoricacidinnonaqueoussolutionsbythecoulometrictitrationmethod
AT jinling determinationoftraceamountsofhydrofluoricacidinnonaqueoussolutionsbythecoulometrictitrationmethod
AT caihongwei determinationoftraceamountsofhydrofluoricacidinnonaqueoussolutionsbythecoulometrictitrationmethod