Therapeutic Effect Enhancement by Dual-Bias High-Voltage Circuit of Transmit Amplifier for Immersion Ultrasound Transducer Applications

The dual-bias high-voltage circuit of a transmit amplifier for immersion ultrasound transducer applications is proposed to enhance the therapeutic effect of human HeLa cells. High-voltage output signals generated from a transmit amplifier are typically preferable for immersion ultrasound transducers...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Hojong, Choe, Se-woon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308538/
https://www.ncbi.nlm.nih.gov/pubmed/30513693
http://dx.doi.org/10.3390/s18124210
_version_ 1783383212693651456
author Choi, Hojong
Choe, Se-woon
author_facet Choi, Hojong
Choe, Se-woon
author_sort Choi, Hojong
collection PubMed
description The dual-bias high-voltage circuit of a transmit amplifier for immersion ultrasound transducer applications is proposed to enhance the therapeutic effect of human HeLa cells. High-voltage output signals generated from a transmit amplifier are typically preferable for immersion ultrasound transducers owing to their high sensitivity at the desired frequency. However, high-voltage output signals typically produce high-order harmonic distortions, thus triggering several unwanted high-order spectral signals in the ultrasound transducers. By reducing high-order harmonic distortions, we expect that improving the signal quality of excited pulses for immersion ultrasound transducers would be beneficial for the therapeutic effect on human cervical cancer HeLa cell suppression. Therefore, an additional bias circuit is developed to merge with the original bias circuit for transmit amplifier to control the harmonic distortions of the immersion ultrasonic transducer. To properly select the components of dual-bias high-voltage circuit, we need to calculate and measure the DC bias voltages of the transmit amplifier with and without dual-bias high-voltage circuit for different period of the time for therapeutic applications. To evaluate the performances of the developed circuit, pulse-echo measurements using a transmit amplifier with or without dual-bias high-voltage circuit were obtained. The measured second, third, and fourth harmonic distortions of the echo signals when using the transmit amplifier with dual-bias high-voltage circuit at 10 V DC bias voltage are lower than those when using the transmit amplifier only. Subsequently, the therapeutic effects using the enhanced performances of the transmit amplifier with dual-bias high-voltage circuit were verified and compared with those using the performances of the transmit amplifier by comparison of quantitative changes in HeLa cell concentrations. The control group without any ultrasonic induction increased the cell density up to about 100% on Day4, however the experimental groups with ultrasonic induction (TA = 91.2 [Formula: see text] 0.8%, TA+Dual-bias high-voltage circuit (0.8 V) = 78.8 [Formula: see text] 1.7% and TA+Dual-bias high-voltage circuit (10 V) = 66.3 [Formula: see text] 1.1%) showed statistically significant cell density changes compared to the control group. We confirmed that the therapeutic effect from using the dual-bias high-voltage circuit is improved. Therefore, it can be a potential candidate to improve the therapeutic effect of HeLa cells.
format Online
Article
Text
id pubmed-6308538
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-63085382019-01-04 Therapeutic Effect Enhancement by Dual-Bias High-Voltage Circuit of Transmit Amplifier for Immersion Ultrasound Transducer Applications Choi, Hojong Choe, Se-woon Sensors (Basel) Article The dual-bias high-voltage circuit of a transmit amplifier for immersion ultrasound transducer applications is proposed to enhance the therapeutic effect of human HeLa cells. High-voltage output signals generated from a transmit amplifier are typically preferable for immersion ultrasound transducers owing to their high sensitivity at the desired frequency. However, high-voltage output signals typically produce high-order harmonic distortions, thus triggering several unwanted high-order spectral signals in the ultrasound transducers. By reducing high-order harmonic distortions, we expect that improving the signal quality of excited pulses for immersion ultrasound transducers would be beneficial for the therapeutic effect on human cervical cancer HeLa cell suppression. Therefore, an additional bias circuit is developed to merge with the original bias circuit for transmit amplifier to control the harmonic distortions of the immersion ultrasonic transducer. To properly select the components of dual-bias high-voltage circuit, we need to calculate and measure the DC bias voltages of the transmit amplifier with and without dual-bias high-voltage circuit for different period of the time for therapeutic applications. To evaluate the performances of the developed circuit, pulse-echo measurements using a transmit amplifier with or without dual-bias high-voltage circuit were obtained. The measured second, third, and fourth harmonic distortions of the echo signals when using the transmit amplifier with dual-bias high-voltage circuit at 10 V DC bias voltage are lower than those when using the transmit amplifier only. Subsequently, the therapeutic effects using the enhanced performances of the transmit amplifier with dual-bias high-voltage circuit were verified and compared with those using the performances of the transmit amplifier by comparison of quantitative changes in HeLa cell concentrations. The control group without any ultrasonic induction increased the cell density up to about 100% on Day4, however the experimental groups with ultrasonic induction (TA = 91.2 [Formula: see text] 0.8%, TA+Dual-bias high-voltage circuit (0.8 V) = 78.8 [Formula: see text] 1.7% and TA+Dual-bias high-voltage circuit (10 V) = 66.3 [Formula: see text] 1.1%) showed statistically significant cell density changes compared to the control group. We confirmed that the therapeutic effect from using the dual-bias high-voltage circuit is improved. Therefore, it can be a potential candidate to improve the therapeutic effect of HeLa cells. MDPI 2018-11-30 /pmc/articles/PMC6308538/ /pubmed/30513693 http://dx.doi.org/10.3390/s18124210 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Choi, Hojong
Choe, Se-woon
Therapeutic Effect Enhancement by Dual-Bias High-Voltage Circuit of Transmit Amplifier for Immersion Ultrasound Transducer Applications
title Therapeutic Effect Enhancement by Dual-Bias High-Voltage Circuit of Transmit Amplifier for Immersion Ultrasound Transducer Applications
title_full Therapeutic Effect Enhancement by Dual-Bias High-Voltage Circuit of Transmit Amplifier for Immersion Ultrasound Transducer Applications
title_fullStr Therapeutic Effect Enhancement by Dual-Bias High-Voltage Circuit of Transmit Amplifier for Immersion Ultrasound Transducer Applications
title_full_unstemmed Therapeutic Effect Enhancement by Dual-Bias High-Voltage Circuit of Transmit Amplifier for Immersion Ultrasound Transducer Applications
title_short Therapeutic Effect Enhancement by Dual-Bias High-Voltage Circuit of Transmit Amplifier for Immersion Ultrasound Transducer Applications
title_sort therapeutic effect enhancement by dual-bias high-voltage circuit of transmit amplifier for immersion ultrasound transducer applications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308538/
https://www.ncbi.nlm.nih.gov/pubmed/30513693
http://dx.doi.org/10.3390/s18124210
work_keys_str_mv AT choihojong therapeuticeffectenhancementbydualbiashighvoltagecircuitoftransmitamplifierforimmersionultrasoundtransducerapplications
AT choesewoon therapeuticeffectenhancementbydualbiashighvoltagecircuitoftransmitamplifierforimmersionultrasoundtransducerapplications