Cargando…
Evaluation of Prestress Loss Distribution during Pre-Tensioning and Post-Tensioning Using Long-Gauge Fiber Bragg Grating Sensors
Prestress loss evaluation in prestressed strands is essential for prestressed structures. However, the sensors installed outside the duct can only measure the total prestress loss. The sensors attached on strands inside the duct also have several problems, such as inadequate durability in an aggress...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308587/ https://www.ncbi.nlm.nih.gov/pubmed/30477164 http://dx.doi.org/10.3390/s18124106 |
_version_ | 1783383224132567040 |
---|---|
author | Shen, Sheng Wang, Yao Ma, Sheng-Lan Huang, Di Wu, Zhi-Hong Guo, Xiao |
author_facet | Shen, Sheng Wang, Yao Ma, Sheng-Lan Huang, Di Wu, Zhi-Hong Guo, Xiao |
author_sort | Shen, Sheng |
collection | PubMed |
description | Prestress loss evaluation in prestressed strands is essential for prestressed structures. However, the sensors installed outside the duct can only measure the total prestress loss. The sensors attached on strands inside the duct also have several problems, such as inadequate durability in an aggressive environment and vulnerability to damage during tensioning. This paper proposes a new installation method for long-gauge fiber Bragg grating (LFBG) sensors to prevent accidental damage. Then the itemized prestress losses were determined in each stage of the pre-tensioning and post-tensioning according to the LFBG measurements. We verified the applicability of the LFBG sensors for prestress monitoring and the accuracy of the proposed prestress loss calculation method during pre-tensioning and post-tensioning. In the pre-tensioning case, the calculated prestress losses had less deviation from the true losses than those obtained from foil-strain gauges, and the durability of the LFBG sensors was better than foil-strain gauges, whereas in post-tensioning case, the calculated prestress losses were close to those derived from theoretical predictions. Finally, we monitored prestress variation in the strand for 90 days. The itemized prestress losses at each stages of post-tensioning were obtained by the proposed calculation method to show the prospect of the LFBG sensors in practical evaluation. |
format | Online Article Text |
id | pubmed-6308587 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-63085872019-01-04 Evaluation of Prestress Loss Distribution during Pre-Tensioning and Post-Tensioning Using Long-Gauge Fiber Bragg Grating Sensors Shen, Sheng Wang, Yao Ma, Sheng-Lan Huang, Di Wu, Zhi-Hong Guo, Xiao Sensors (Basel) Article Prestress loss evaluation in prestressed strands is essential for prestressed structures. However, the sensors installed outside the duct can only measure the total prestress loss. The sensors attached on strands inside the duct also have several problems, such as inadequate durability in an aggressive environment and vulnerability to damage during tensioning. This paper proposes a new installation method for long-gauge fiber Bragg grating (LFBG) sensors to prevent accidental damage. Then the itemized prestress losses were determined in each stage of the pre-tensioning and post-tensioning according to the LFBG measurements. We verified the applicability of the LFBG sensors for prestress monitoring and the accuracy of the proposed prestress loss calculation method during pre-tensioning and post-tensioning. In the pre-tensioning case, the calculated prestress losses had less deviation from the true losses than those obtained from foil-strain gauges, and the durability of the LFBG sensors was better than foil-strain gauges, whereas in post-tensioning case, the calculated prestress losses were close to those derived from theoretical predictions. Finally, we monitored prestress variation in the strand for 90 days. The itemized prestress losses at each stages of post-tensioning were obtained by the proposed calculation method to show the prospect of the LFBG sensors in practical evaluation. MDPI 2018-11-23 /pmc/articles/PMC6308587/ /pubmed/30477164 http://dx.doi.org/10.3390/s18124106 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Shen, Sheng Wang, Yao Ma, Sheng-Lan Huang, Di Wu, Zhi-Hong Guo, Xiao Evaluation of Prestress Loss Distribution during Pre-Tensioning and Post-Tensioning Using Long-Gauge Fiber Bragg Grating Sensors |
title | Evaluation of Prestress Loss Distribution during Pre-Tensioning and Post-Tensioning Using Long-Gauge Fiber Bragg Grating Sensors |
title_full | Evaluation of Prestress Loss Distribution during Pre-Tensioning and Post-Tensioning Using Long-Gauge Fiber Bragg Grating Sensors |
title_fullStr | Evaluation of Prestress Loss Distribution during Pre-Tensioning and Post-Tensioning Using Long-Gauge Fiber Bragg Grating Sensors |
title_full_unstemmed | Evaluation of Prestress Loss Distribution during Pre-Tensioning and Post-Tensioning Using Long-Gauge Fiber Bragg Grating Sensors |
title_short | Evaluation of Prestress Loss Distribution during Pre-Tensioning and Post-Tensioning Using Long-Gauge Fiber Bragg Grating Sensors |
title_sort | evaluation of prestress loss distribution during pre-tensioning and post-tensioning using long-gauge fiber bragg grating sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308587/ https://www.ncbi.nlm.nih.gov/pubmed/30477164 http://dx.doi.org/10.3390/s18124106 |
work_keys_str_mv | AT shensheng evaluationofprestresslossdistributionduringpretensioningandposttensioningusinglonggaugefiberbragggratingsensors AT wangyao evaluationofprestresslossdistributionduringpretensioningandposttensioningusinglonggaugefiberbragggratingsensors AT mashenglan evaluationofprestresslossdistributionduringpretensioningandposttensioningusinglonggaugefiberbragggratingsensors AT huangdi evaluationofprestresslossdistributionduringpretensioningandposttensioningusinglonggaugefiberbragggratingsensors AT wuzhihong evaluationofprestresslossdistributionduringpretensioningandposttensioningusinglonggaugefiberbragggratingsensors AT guoxiao evaluationofprestresslossdistributionduringpretensioningandposttensioningusinglonggaugefiberbragggratingsensors |