Experimental Phantom-Based Security Analysis for Next-Generation Leadless Cardiac Pacemakers

With technological advancement, implanted medical devices can treat a wide range of chronic diseases such as cardiac arrhythmia, deafness, diabetes, etc. Cardiac pacemakers are used to maintain normal heart rhythms. The next generation of these pacemakers is expected to be completely wireless, provi...

Descripción completa

Detalles Bibliográficos
Autores principales: Awan, Muhammad Faheem, Perez-Simbor, Sofia, Garcia-Pardo, Concepcion, Kansanen, Kimmo, Cardona, Narcis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308590/
https://www.ncbi.nlm.nih.gov/pubmed/30544594
http://dx.doi.org/10.3390/s18124327
_version_ 1783383224860278784
author Awan, Muhammad Faheem
Perez-Simbor, Sofia
Garcia-Pardo, Concepcion
Kansanen, Kimmo
Cardona, Narcis
author_facet Awan, Muhammad Faheem
Perez-Simbor, Sofia
Garcia-Pardo, Concepcion
Kansanen, Kimmo
Cardona, Narcis
author_sort Awan, Muhammad Faheem
collection PubMed
description With technological advancement, implanted medical devices can treat a wide range of chronic diseases such as cardiac arrhythmia, deafness, diabetes, etc. Cardiac pacemakers are used to maintain normal heart rhythms. The next generation of these pacemakers is expected to be completely wireless, providing new security threats. Thus, it is critical to secure pacemaker transmissions between legitimate nodes from a third party or an eavesdropper. This work estimates the eavesdropping risk and explores the potential of securing transmissions between leadless capsules inside the heart and the subcutaneous implant under the skin against external eavesdroppers by using physical-layer security methods. In this work, we perform phantom experiments to replicate the dielectric properties of the human heart, blood, and fat for channel modeling between in-body-to-in-body devices and from in-body-to-off-body scenario. These scenarios reflect the channel between legitimate nodes and that between a legitimate node and an eavesdropper. In our case, a legitimate node is a leadless cardiac pacemaker implanted in the right ventricle of a human heart transmitting to a legitimate receiver, which is a subcutaneous implant beneath the collar bone under the skin. In addition, a third party outside the body is trying to eavesdrop the communication. The measurements are performed for ultrawide band (UWB) and industrial, scientific, and medical (ISM) frequency bands. By using these channel models, we analyzed the risk of using the concept of outage probability and determine the eavesdropping range in the case of using UWB and ISM frequency bands. Furthermore, the probability of positive secrecy capacity is also determined, along with outage probability of a secrecy rate, which are the fundamental parameters in depicting the physical-layer security methods. Here, we show that path loss follows a log-normal distribution. In addition, for the ISM frequency band, the probability of successful eavesdropping for a data rate of 600 kbps (Electromyogram (EMG)) is about 97.68% at an eavesdropper distance of 1.3 m and approaches 28.13% at an eavesdropper distance of 4.2 m, whereas for UWB frequency band the eavesdropping risk approaches 0.2847% at an eavesdropper distance of 0.22 m. Furthermore, the probability of positive secrecy capacity is about 44.88% at eavesdropper distance of 0.12 m and approaches approximately 97% at an eavesdropper distance of 0.4 m for ISM frequency band, whereas for UWB, the same statistics are 96.84% at 0.12 m and 100% at 0.4 m. Moreover, the outage probability of secrecy capacity is also determined by using a fixed secrecy rate.
format Online
Article
Text
id pubmed-6308590
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-63085902019-01-04 Experimental Phantom-Based Security Analysis for Next-Generation Leadless Cardiac Pacemakers Awan, Muhammad Faheem Perez-Simbor, Sofia Garcia-Pardo, Concepcion Kansanen, Kimmo Cardona, Narcis Sensors (Basel) Article With technological advancement, implanted medical devices can treat a wide range of chronic diseases such as cardiac arrhythmia, deafness, diabetes, etc. Cardiac pacemakers are used to maintain normal heart rhythms. The next generation of these pacemakers is expected to be completely wireless, providing new security threats. Thus, it is critical to secure pacemaker transmissions between legitimate nodes from a third party or an eavesdropper. This work estimates the eavesdropping risk and explores the potential of securing transmissions between leadless capsules inside the heart and the subcutaneous implant under the skin against external eavesdroppers by using physical-layer security methods. In this work, we perform phantom experiments to replicate the dielectric properties of the human heart, blood, and fat for channel modeling between in-body-to-in-body devices and from in-body-to-off-body scenario. These scenarios reflect the channel between legitimate nodes and that between a legitimate node and an eavesdropper. In our case, a legitimate node is a leadless cardiac pacemaker implanted in the right ventricle of a human heart transmitting to a legitimate receiver, which is a subcutaneous implant beneath the collar bone under the skin. In addition, a third party outside the body is trying to eavesdrop the communication. The measurements are performed for ultrawide band (UWB) and industrial, scientific, and medical (ISM) frequency bands. By using these channel models, we analyzed the risk of using the concept of outage probability and determine the eavesdropping range in the case of using UWB and ISM frequency bands. Furthermore, the probability of positive secrecy capacity is also determined, along with outage probability of a secrecy rate, which are the fundamental parameters in depicting the physical-layer security methods. Here, we show that path loss follows a log-normal distribution. In addition, for the ISM frequency band, the probability of successful eavesdropping for a data rate of 600 kbps (Electromyogram (EMG)) is about 97.68% at an eavesdropper distance of 1.3 m and approaches 28.13% at an eavesdropper distance of 4.2 m, whereas for UWB frequency band the eavesdropping risk approaches 0.2847% at an eavesdropper distance of 0.22 m. Furthermore, the probability of positive secrecy capacity is about 44.88% at eavesdropper distance of 0.12 m and approaches approximately 97% at an eavesdropper distance of 0.4 m for ISM frequency band, whereas for UWB, the same statistics are 96.84% at 0.12 m and 100% at 0.4 m. Moreover, the outage probability of secrecy capacity is also determined by using a fixed secrecy rate. MDPI 2018-12-07 /pmc/articles/PMC6308590/ /pubmed/30544594 http://dx.doi.org/10.3390/s18124327 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Awan, Muhammad Faheem
Perez-Simbor, Sofia
Garcia-Pardo, Concepcion
Kansanen, Kimmo
Cardona, Narcis
Experimental Phantom-Based Security Analysis for Next-Generation Leadless Cardiac Pacemakers
title Experimental Phantom-Based Security Analysis for Next-Generation Leadless Cardiac Pacemakers
title_full Experimental Phantom-Based Security Analysis for Next-Generation Leadless Cardiac Pacemakers
title_fullStr Experimental Phantom-Based Security Analysis for Next-Generation Leadless Cardiac Pacemakers
title_full_unstemmed Experimental Phantom-Based Security Analysis for Next-Generation Leadless Cardiac Pacemakers
title_short Experimental Phantom-Based Security Analysis for Next-Generation Leadless Cardiac Pacemakers
title_sort experimental phantom-based security analysis for next-generation leadless cardiac pacemakers
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6308590/
https://www.ncbi.nlm.nih.gov/pubmed/30544594
http://dx.doi.org/10.3390/s18124327
work_keys_str_mv AT awanmuhammadfaheem experimentalphantombasedsecurityanalysisfornextgenerationleadlesscardiacpacemakers
AT perezsimborsofia experimentalphantombasedsecurityanalysisfornextgenerationleadlesscardiacpacemakers
AT garciapardoconcepcion experimentalphantombasedsecurityanalysisfornextgenerationleadlesscardiacpacemakers
AT kansanenkimmo experimentalphantombasedsecurityanalysisfornextgenerationleadlesscardiacpacemakers
AT cardonanarcis experimentalphantombasedsecurityanalysisfornextgenerationleadlesscardiacpacemakers