Zero contrast optical coherence tomography–guided percutaneous coronary intervention for in-stent restenosis of the saphenous vein graft using a non-contrast flush medium
Percutaneous coronary intervention (PCI) is often denied for individuals with coronary artery disease who are prone to develop contrast-induced acute kidney injury. We report a 73-year-old, stage 3 chronic kidney disease patient (CKD), who underwent coronary artery bypass surgery and saphenous vein...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6309879/ https://www.ncbi.nlm.nih.gov/pubmed/30595315 http://dx.doi.org/10.1016/j.ihj.2018.11.001 |
_version_ | 1783383393112686592 |
---|---|
author | Vasu, Nandhakumar Subban, Vijayakumar Ajit Mullasari, S. |
author_facet | Vasu, Nandhakumar Subban, Vijayakumar Ajit Mullasari, S. |
author_sort | Vasu, Nandhakumar |
collection | PubMed |
description | Percutaneous coronary intervention (PCI) is often denied for individuals with coronary artery disease who are prone to develop contrast-induced acute kidney injury. We report a 73-year-old, stage 3 chronic kidney disease patient (CKD), who underwent coronary artery bypass surgery and saphenous vein graft (SVG) stenting in the past, presented with in-stent restenosis (ISR) of SVG stent. Zero contrast optical coherence tomography (OCT) guided–PCI was successfully performed using low molecular weight dextran-40 (LMWD-40) as the flush medium. Our report suggests the safety and feasibility of LMWD-40–based OCT-guided zero contrast PCI in ISR of SVG in a CKD patient, although further prospective studies are needed to evaluate this technique. |
format | Online Article Text |
id | pubmed-6309879 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-63098792019-12-01 Zero contrast optical coherence tomography–guided percutaneous coronary intervention for in-stent restenosis of the saphenous vein graft using a non-contrast flush medium Vasu, Nandhakumar Subban, Vijayakumar Ajit Mullasari, S. Indian Heart J Short Communication Percutaneous coronary intervention (PCI) is often denied for individuals with coronary artery disease who are prone to develop contrast-induced acute kidney injury. We report a 73-year-old, stage 3 chronic kidney disease patient (CKD), who underwent coronary artery bypass surgery and saphenous vein graft (SVG) stenting in the past, presented with in-stent restenosis (ISR) of SVG stent. Zero contrast optical coherence tomography (OCT) guided–PCI was successfully performed using low molecular weight dextran-40 (LMWD-40) as the flush medium. Our report suggests the safety and feasibility of LMWD-40–based OCT-guided zero contrast PCI in ISR of SVG in a CKD patient, although further prospective studies are needed to evaluate this technique. Elsevier 2018-12 2018-11-09 /pmc/articles/PMC6309879/ /pubmed/30595315 http://dx.doi.org/10.1016/j.ihj.2018.11.001 Text en © 2018 Cardiological Society of India. Published by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Short Communication Vasu, Nandhakumar Subban, Vijayakumar Ajit Mullasari, S. Zero contrast optical coherence tomography–guided percutaneous coronary intervention for in-stent restenosis of the saphenous vein graft using a non-contrast flush medium |
title | Zero contrast optical coherence tomography–guided percutaneous coronary intervention for in-stent restenosis of the saphenous vein graft using a non-contrast flush medium |
title_full | Zero contrast optical coherence tomography–guided percutaneous coronary intervention for in-stent restenosis of the saphenous vein graft using a non-contrast flush medium |
title_fullStr | Zero contrast optical coherence tomography–guided percutaneous coronary intervention for in-stent restenosis of the saphenous vein graft using a non-contrast flush medium |
title_full_unstemmed | Zero contrast optical coherence tomography–guided percutaneous coronary intervention for in-stent restenosis of the saphenous vein graft using a non-contrast flush medium |
title_short | Zero contrast optical coherence tomography–guided percutaneous coronary intervention for in-stent restenosis of the saphenous vein graft using a non-contrast flush medium |
title_sort | zero contrast optical coherence tomography–guided percutaneous coronary intervention for in-stent restenosis of the saphenous vein graft using a non-contrast flush medium |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6309879/ https://www.ncbi.nlm.nih.gov/pubmed/30595315 http://dx.doi.org/10.1016/j.ihj.2018.11.001 |
work_keys_str_mv | AT vasunandhakumar zerocontrastopticalcoherencetomographyguidedpercutaneouscoronaryinterventionforinstentrestenosisofthesaphenousveingraftusinganoncontrastflushmedium AT subbanvijayakumar zerocontrastopticalcoherencetomographyguidedpercutaneouscoronaryinterventionforinstentrestenosisofthesaphenousveingraftusinganoncontrastflushmedium AT ajitmullasaris zerocontrastopticalcoherencetomographyguidedpercutaneouscoronaryinterventionforinstentrestenosisofthesaphenousveingraftusinganoncontrastflushmedium |