Cargando…

Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions

BACKGROUND: Vinyl Polyether Siloxane is a newly introduced impression material and studies on that is scarce. Implant insertion in posterior mandible might be angulated due to anatomical considerations. The purpose of this study was to compare the dimensional and angular accuracy of impressions usin...

Descripción completa

Detalles Bibliográficos
Autores principales: Siadat, Hakimeh, Saeidi, Zeinab, Alikhasi, Marzieh, Zeighami, Somayeh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6311409/
https://www.ncbi.nlm.nih.gov/pubmed/30607227
http://dx.doi.org/10.4317/jced.55227
_version_ 1783383610378682368
author Siadat, Hakimeh
Saeidi, Zeinab
Alikhasi, Marzieh
Zeighami, Somayeh
author_facet Siadat, Hakimeh
Saeidi, Zeinab
Alikhasi, Marzieh
Zeighami, Somayeh
author_sort Siadat, Hakimeh
collection PubMed
description BACKGROUND: Vinyl Polyether Siloxane is a newly introduced impression material and studies on that is scarce. Implant insertion in posterior mandible might be angulated due to anatomical considerations. The purpose of this study was to compare the dimensional and angular accuracy of impressions using full-arch versus sectional tray and Vinyl Polysiloxane versus Vinyl Polyether Siloxane in angulated implants. MATERIAL AND METHODS: Four implants were placed in dental areas #19, #21, #28 and #30 of a Kennedy class I mandibular acrylic model with 30° lingual angulation. Twenty sectional and 20 full-arch open trays were made on the primary cast. Impressions were taken using Vinyl Polysiloxane and Vinyl Polyether Siloxane (n=10 in 4 groups); and were poured with type IV dental stone. The coordinate measuring machine was used to measure displacements in the X, Y and Z axes and rotational discrepancies of implants. The data were analyzed using SPSS 22 and two-way ANOVA. RESULTS: Type of tray had no significant effect on the dimensional and angular accuracy of impressions (p >0.05). Type of impression material significantly affected linear displacement (∆r) (P <0.05); but it did not significantly affect the rotational displacement (P >0.05). CONCLUSIONS: Vinyl Polysiloxane yielded more accurate impressions of angulated implants. Key words:Dental implant, impression material, impression tray, vinyl polysiloxane, vinyl polyether silicone, coordinate measuring machine.
format Online
Article
Text
id pubmed-6311409
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-63114092019-01-03 Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions Siadat, Hakimeh Saeidi, Zeinab Alikhasi, Marzieh Zeighami, Somayeh J Clin Exp Dent Research BACKGROUND: Vinyl Polyether Siloxane is a newly introduced impression material and studies on that is scarce. Implant insertion in posterior mandible might be angulated due to anatomical considerations. The purpose of this study was to compare the dimensional and angular accuracy of impressions using full-arch versus sectional tray and Vinyl Polysiloxane versus Vinyl Polyether Siloxane in angulated implants. MATERIAL AND METHODS: Four implants were placed in dental areas #19, #21, #28 and #30 of a Kennedy class I mandibular acrylic model with 30° lingual angulation. Twenty sectional and 20 full-arch open trays were made on the primary cast. Impressions were taken using Vinyl Polysiloxane and Vinyl Polyether Siloxane (n=10 in 4 groups); and were poured with type IV dental stone. The coordinate measuring machine was used to measure displacements in the X, Y and Z axes and rotational discrepancies of implants. The data were analyzed using SPSS 22 and two-way ANOVA. RESULTS: Type of tray had no significant effect on the dimensional and angular accuracy of impressions (p >0.05). Type of impression material significantly affected linear displacement (∆r) (P <0.05); but it did not significantly affect the rotational displacement (P >0.05). CONCLUSIONS: Vinyl Polysiloxane yielded more accurate impressions of angulated implants. Key words:Dental implant, impression material, impression tray, vinyl polysiloxane, vinyl polyether silicone, coordinate measuring machine. Medicina Oral S.L. 2018-11-01 /pmc/articles/PMC6311409/ /pubmed/30607227 http://dx.doi.org/10.4317/jced.55227 Text en Copyright: © 2018 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Siadat, Hakimeh
Saeidi, Zeinab
Alikhasi, Marzieh
Zeighami, Somayeh
Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions
title Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions
title_full Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions
title_fullStr Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions
title_full_unstemmed Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions
title_short Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions
title_sort comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6311409/
https://www.ncbi.nlm.nih.gov/pubmed/30607227
http://dx.doi.org/10.4317/jced.55227
work_keys_str_mv AT siadathakimeh comparativeevaluationoftheeffectofimpressionmaterialsandtraysontheaccuracyofangulatedimplantsimpressions
AT saeidizeinab comparativeevaluationoftheeffectofimpressionmaterialsandtraysontheaccuracyofangulatedimplantsimpressions
AT alikhasimarzieh comparativeevaluationoftheeffectofimpressionmaterialsandtraysontheaccuracyofangulatedimplantsimpressions
AT zeighamisomayeh comparativeevaluationoftheeffectofimpressionmaterialsandtraysontheaccuracyofangulatedimplantsimpressions