Cargando…

A GC–MS method for the determination of furanylfentanyl and ocfentanil in whole blood with full validation

PURPOSE: Fentanyl analogues are popular in recent years among drug addicts and have been related to many overdoses and deaths worldwide. Furanylfentanyl, ocfentanil, acetylfentanyl and butyrfentanyl are among the most common of these drugs. Methods for the determination of furanylfentanyl and ocfent...

Descripción completa

Detalles Bibliográficos
Autores principales: Misailidi, Nektaria, Athanaselis, Sotiris, Nikolaou, Panagiota, Katselou, Maria, Dotsikas, Yannis, Spiliopoulou, Chara, Papoutsis, Ioannis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Japan 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6314982/
https://www.ncbi.nlm.nih.gov/pubmed/30636990
http://dx.doi.org/10.1007/s11419-018-0449-2
_version_ 1783384182137815040
author Misailidi, Nektaria
Athanaselis, Sotiris
Nikolaou, Panagiota
Katselou, Maria
Dotsikas, Yannis
Spiliopoulou, Chara
Papoutsis, Ioannis
author_facet Misailidi, Nektaria
Athanaselis, Sotiris
Nikolaou, Panagiota
Katselou, Maria
Dotsikas, Yannis
Spiliopoulou, Chara
Papoutsis, Ioannis
author_sort Misailidi, Nektaria
collection PubMed
description PURPOSE: Fentanyl analogues are popular in recent years among drug addicts and have been related to many overdoses and deaths worldwide. Furanylfentanyl, ocfentanil, acetylfentanyl and butyrfentanyl are among the most common of these drugs. Methods for the determination of furanylfentanyl and ocfentanil by gas chromatography–mass spectrometry (GC–MS) in biological samples do not exist, and therefore, their development would be extremely useful for routine toxicological analysis. METHODS: A GC–MS method was developed and fully validated for the determination of furanylfentanyl and ocfentanil in whole blood. This method was also suitable for the determination of acetylfentanyl and butyrfentanyl. The method included solid-phase extraction after protein precipitation using acetonitrile, and it was applied during the toxicological investigation of forensic cases. Methadone-d(3) was used as internal standard for the quantification of the analytes. RESULTS: The limit of detection and limit of quantification values were 0.30 and 1.0 ng/mL for furanylfentanyl and ocfentanil and 0.15 and 0.50 ng/mL for acetylfentanyl and butyrfentanyl, respectively. The calibration curves were linear (R(2) ≥ 0.993) from 1.00 to 100 ng/mL for furanylfentanyl and ocfentanil and from 0.50 to 50.0 ng/mL for acetylfentanyl and butyrfentanyl. The recoveries were not lower than 85%, while accuracies and precisions were not greater than 6.0% (% error) and 8.0% (% relative standard deviation), respectively, for all four fentanyl analogues. CONCLUSIONS: The developed method is the first one in the literature for the detection of furanylfentanyl and ocfentanil in biological fluids by GC–MS, and it provides very high sensitivity comparable to that by liquid chromatography–tandem mass spectrometry.
format Online
Article
Text
id pubmed-6314982
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Japan
record_format MEDLINE/PubMed
spelling pubmed-63149822019-01-11 A GC–MS method for the determination of furanylfentanyl and ocfentanil in whole blood with full validation Misailidi, Nektaria Athanaselis, Sotiris Nikolaou, Panagiota Katselou, Maria Dotsikas, Yannis Spiliopoulou, Chara Papoutsis, Ioannis Forensic Toxicol Short Communication PURPOSE: Fentanyl analogues are popular in recent years among drug addicts and have been related to many overdoses and deaths worldwide. Furanylfentanyl, ocfentanil, acetylfentanyl and butyrfentanyl are among the most common of these drugs. Methods for the determination of furanylfentanyl and ocfentanil by gas chromatography–mass spectrometry (GC–MS) in biological samples do not exist, and therefore, their development would be extremely useful for routine toxicological analysis. METHODS: A GC–MS method was developed and fully validated for the determination of furanylfentanyl and ocfentanil in whole blood. This method was also suitable for the determination of acetylfentanyl and butyrfentanyl. The method included solid-phase extraction after protein precipitation using acetonitrile, and it was applied during the toxicological investigation of forensic cases. Methadone-d(3) was used as internal standard for the quantification of the analytes. RESULTS: The limit of detection and limit of quantification values were 0.30 and 1.0 ng/mL for furanylfentanyl and ocfentanil and 0.15 and 0.50 ng/mL for acetylfentanyl and butyrfentanyl, respectively. The calibration curves were linear (R(2) ≥ 0.993) from 1.00 to 100 ng/mL for furanylfentanyl and ocfentanil and from 0.50 to 50.0 ng/mL for acetylfentanyl and butyrfentanyl. The recoveries were not lower than 85%, while accuracies and precisions were not greater than 6.0% (% error) and 8.0% (% relative standard deviation), respectively, for all four fentanyl analogues. CONCLUSIONS: The developed method is the first one in the literature for the detection of furanylfentanyl and ocfentanil in biological fluids by GC–MS, and it provides very high sensitivity comparable to that by liquid chromatography–tandem mass spectrometry. Springer Japan 2018-10-22 2019 /pmc/articles/PMC6314982/ /pubmed/30636990 http://dx.doi.org/10.1007/s11419-018-0449-2 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Short Communication
Misailidi, Nektaria
Athanaselis, Sotiris
Nikolaou, Panagiota
Katselou, Maria
Dotsikas, Yannis
Spiliopoulou, Chara
Papoutsis, Ioannis
A GC–MS method for the determination of furanylfentanyl and ocfentanil in whole blood with full validation
title A GC–MS method for the determination of furanylfentanyl and ocfentanil in whole blood with full validation
title_full A GC–MS method for the determination of furanylfentanyl and ocfentanil in whole blood with full validation
title_fullStr A GC–MS method for the determination of furanylfentanyl and ocfentanil in whole blood with full validation
title_full_unstemmed A GC–MS method for the determination of furanylfentanyl and ocfentanil in whole blood with full validation
title_short A GC–MS method for the determination of furanylfentanyl and ocfentanil in whole blood with full validation
title_sort gc–ms method for the determination of furanylfentanyl and ocfentanil in whole blood with full validation
topic Short Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6314982/
https://www.ncbi.nlm.nih.gov/pubmed/30636990
http://dx.doi.org/10.1007/s11419-018-0449-2
work_keys_str_mv AT misailidinektaria agcmsmethodforthedeterminationoffuranylfentanylandocfentanilinwholebloodwithfullvalidation
AT athanaselissotiris agcmsmethodforthedeterminationoffuranylfentanylandocfentanilinwholebloodwithfullvalidation
AT nikolaoupanagiota agcmsmethodforthedeterminationoffuranylfentanylandocfentanilinwholebloodwithfullvalidation
AT katseloumaria agcmsmethodforthedeterminationoffuranylfentanylandocfentanilinwholebloodwithfullvalidation
AT dotsikasyannis agcmsmethodforthedeterminationoffuranylfentanylandocfentanilinwholebloodwithfullvalidation
AT spiliopoulouchara agcmsmethodforthedeterminationoffuranylfentanylandocfentanilinwholebloodwithfullvalidation
AT papoutsisioannis agcmsmethodforthedeterminationoffuranylfentanylandocfentanilinwholebloodwithfullvalidation
AT misailidinektaria gcmsmethodforthedeterminationoffuranylfentanylandocfentanilinwholebloodwithfullvalidation
AT athanaselissotiris gcmsmethodforthedeterminationoffuranylfentanylandocfentanilinwholebloodwithfullvalidation
AT nikolaoupanagiota gcmsmethodforthedeterminationoffuranylfentanylandocfentanilinwholebloodwithfullvalidation
AT katseloumaria gcmsmethodforthedeterminationoffuranylfentanylandocfentanilinwholebloodwithfullvalidation
AT dotsikasyannis gcmsmethodforthedeterminationoffuranylfentanylandocfentanilinwholebloodwithfullvalidation
AT spiliopoulouchara gcmsmethodforthedeterminationoffuranylfentanylandocfentanilinwholebloodwithfullvalidation
AT papoutsisioannis gcmsmethodforthedeterminationoffuranylfentanylandocfentanilinwholebloodwithfullvalidation