Cargando…

Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study

OBJECTIVE: To investigate the efficacy of motion-correction algorithm (MCA) in improving coronary artery image quality and measurement accuracy using an anthropomorphic dynamic heart phantom and 256-detector row computed tomography (CT) scanner. MATERIALS AND METHODS: An anthropomorphic dynamic hear...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Jeong Bin, Jeong, Yeon Joo, Lee, Geewon, Lee, Nam Kyung, Kim, Jin You, Lee, Ji Won
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6315068/
https://www.ncbi.nlm.nih.gov/pubmed/30627025
http://dx.doi.org/10.3348/kjr.2018.0251
_version_ 1783384203041177600
author Park, Jeong Bin
Jeong, Yeon Joo
Lee, Geewon
Lee, Nam Kyung
Kim, Jin You
Lee, Ji Won
author_facet Park, Jeong Bin
Jeong, Yeon Joo
Lee, Geewon
Lee, Nam Kyung
Kim, Jin You
Lee, Ji Won
author_sort Park, Jeong Bin
collection PubMed
description OBJECTIVE: To investigate the efficacy of motion-correction algorithm (MCA) in improving coronary artery image quality and measurement accuracy using an anthropomorphic dynamic heart phantom and 256-detector row computed tomography (CT) scanner. MATERIALS AND METHODS: An anthropomorphic dynamic heart phantom was scanned under a static condition and under heart rate (HR) simulation of 50–120 beats per minute (bpm), and the obtained images were reconstructed using conventional algorithm (CA) and MCA. We compared the subjective image quality of coronary arteries using a four-point scale (1, excellent; 2, good; 3, fair; 4, poor) and measurement accuracy using measurement errors of the minimal luminal diameter (MLD) and minimal luminal area (MLA). RESULTS: Compared with CA, MCA significantly improved the subjective image quality at HRs of 110 bpm (1.3 ± 0.3 vs. 1.9 ± 0.8, p = 0.003) and 120 bpm (1.7 ± 0.7 vs. 2.3 ± 0.6, p = 0.006). The measurement error of MLD significantly decreased on using MCA at 110 bpm (11.7 ± 5.9% vs. 18.4 ± 9.4%, p = 0.013) and 120 bpm (10.0 ± 7.3% vs. 25.0 ± 16.5%, p = 0.013). The measurement error of the MLA was also reduced using MCA at 110 bpm (19.2 ± 28.1% vs. 26.4 ± 21.6%, p = 0.028) and 120 bpm (17.9 ± 17.7% vs. 34.8 ± 19.6%, p = 0.018). CONCLUSION: Motion-correction algorithm can improve the coronary artery image quality and measurement accuracy at a high HR using an anthropomorphic dynamic heart phantom and 256-detector row CT scanner.
format Online
Article
Text
id pubmed-6315068
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-63150682019-01-09 Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study Park, Jeong Bin Jeong, Yeon Joo Lee, Geewon Lee, Nam Kyung Kim, Jin You Lee, Ji Won Korean J Radiol Cardiovascular Imaging OBJECTIVE: To investigate the efficacy of motion-correction algorithm (MCA) in improving coronary artery image quality and measurement accuracy using an anthropomorphic dynamic heart phantom and 256-detector row computed tomography (CT) scanner. MATERIALS AND METHODS: An anthropomorphic dynamic heart phantom was scanned under a static condition and under heart rate (HR) simulation of 50–120 beats per minute (bpm), and the obtained images were reconstructed using conventional algorithm (CA) and MCA. We compared the subjective image quality of coronary arteries using a four-point scale (1, excellent; 2, good; 3, fair; 4, poor) and measurement accuracy using measurement errors of the minimal luminal diameter (MLD) and minimal luminal area (MLA). RESULTS: Compared with CA, MCA significantly improved the subjective image quality at HRs of 110 bpm (1.3 ± 0.3 vs. 1.9 ± 0.8, p = 0.003) and 120 bpm (1.7 ± 0.7 vs. 2.3 ± 0.6, p = 0.006). The measurement error of MLD significantly decreased on using MCA at 110 bpm (11.7 ± 5.9% vs. 18.4 ± 9.4%, p = 0.013) and 120 bpm (10.0 ± 7.3% vs. 25.0 ± 16.5%, p = 0.013). The measurement error of the MLA was also reduced using MCA at 110 bpm (19.2 ± 28.1% vs. 26.4 ± 21.6%, p = 0.028) and 120 bpm (17.9 ± 17.7% vs. 34.8 ± 19.6%, p = 0.018). CONCLUSION: Motion-correction algorithm can improve the coronary artery image quality and measurement accuracy at a high HR using an anthropomorphic dynamic heart phantom and 256-detector row CT scanner. The Korean Society of Radiology 2019-01 2018-12-27 /pmc/articles/PMC6315068/ /pubmed/30627025 http://dx.doi.org/10.3348/kjr.2018.0251 Text en Copyright © 2019 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cardiovascular Imaging
Park, Jeong Bin
Jeong, Yeon Joo
Lee, Geewon
Lee, Nam Kyung
Kim, Jin You
Lee, Ji Won
Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study
title Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study
title_full Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study
title_fullStr Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study
title_full_unstemmed Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study
title_short Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study
title_sort influence of heart rate and innovative motion-correction algorithm on coronary artery image quality and measurement accuracy using 256-detector row computed tomography scanner: phantom study
topic Cardiovascular Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6315068/
https://www.ncbi.nlm.nih.gov/pubmed/30627025
http://dx.doi.org/10.3348/kjr.2018.0251
work_keys_str_mv AT parkjeongbin influenceofheartrateandinnovativemotioncorrectionalgorithmoncoronaryarteryimagequalityandmeasurementaccuracyusing256detectorrowcomputedtomographyscannerphantomstudy
AT jeongyeonjoo influenceofheartrateandinnovativemotioncorrectionalgorithmoncoronaryarteryimagequalityandmeasurementaccuracyusing256detectorrowcomputedtomographyscannerphantomstudy
AT leegeewon influenceofheartrateandinnovativemotioncorrectionalgorithmoncoronaryarteryimagequalityandmeasurementaccuracyusing256detectorrowcomputedtomographyscannerphantomstudy
AT leenamkyung influenceofheartrateandinnovativemotioncorrectionalgorithmoncoronaryarteryimagequalityandmeasurementaccuracyusing256detectorrowcomputedtomographyscannerphantomstudy
AT kimjinyou influenceofheartrateandinnovativemotioncorrectionalgorithmoncoronaryarteryimagequalityandmeasurementaccuracyusing256detectorrowcomputedtomographyscannerphantomstudy
AT leejiwon influenceofheartrateandinnovativemotioncorrectionalgorithmoncoronaryarteryimagequalityandmeasurementaccuracyusing256detectorrowcomputedtomographyscannerphantomstudy