Cargando…
Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI
OBJECTIVE: Segmented cardiac cine magnetic resonance imaging (MRI) is the gold standard for cardiac ventricular volumetric assessment. In patients with difficulty in breath-holding or arrhythmia, this technique may generate images with inadequate quality for diagnosis. Real-time cardiac cine MRI has...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6315079/ https://www.ncbi.nlm.nih.gov/pubmed/30627027 http://dx.doi.org/10.3348/kjr.2018.0243 |
_version_ | 1783384205749649408 |
---|---|
author | Cui, Chen Yin, Gang Lu, Minjie Chen, Xiuyu Cheng, Sainan Li, Lu Yan, Weipeng Song, Yanyan Prasad, Sanjay Zhang, Yan Zhao, Shihua |
author_facet | Cui, Chen Yin, Gang Lu, Minjie Chen, Xiuyu Cheng, Sainan Li, Lu Yan, Weipeng Song, Yanyan Prasad, Sanjay Zhang, Yan Zhao, Shihua |
author_sort | Cui, Chen |
collection | PubMed |
description | OBJECTIVE: Segmented cardiac cine magnetic resonance imaging (MRI) is the gold standard for cardiac ventricular volumetric assessment. In patients with difficulty in breath-holding or arrhythmia, this technique may generate images with inadequate quality for diagnosis. Real-time cardiac cine MRI has been developed to address this limitation. We aimed to assess the performance of retrospective electrocardiography-gated real-time cine MRI at 3T for left ventricular (LV) volume and mass measurement. MATERIALS AND METHODS: Fifty-one patients were consecutively enrolled. A series of short-axis cine images covering the entire left ventricle using both segmented and real-time balanced steady-state free precession cardiac cine MRI were obtained. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass were measured. The agreement and correlation of the parameters were assessed. Additionally, image quality was evaluated using European CMR Registry (Euro-CMR) score and structure visibility rating. RESULTS: In patients without difficulty in breath-holding or arrhythmia, no significant difference was found in Euro-CMR score between the two techniques (0.3 ± 0.7 vs. 0.3 ± 0.5, p > 0.05). Good agreements and correlations were found between the techniques for measuring EDV, ESV, EF, SV, and LV mass. In patients with difficulty in breath-holding or arrhythmia, segmented cine MRI had a significant higher Euro-CMR score (2.3 ± 1.2 vs. 0.4 ± 0.5, p < 0.001). CONCLUSION: Real-time cine MRI at 3T allowed the assessment of LV volume with high accuracy and showed a significantly better image quality compared to that of segmented cine MRI in patients with difficulty in breath-holding and arrhythmia. |
format | Online Article Text |
id | pubmed-6315079 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-63150792019-01-09 Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI Cui, Chen Yin, Gang Lu, Minjie Chen, Xiuyu Cheng, Sainan Li, Lu Yan, Weipeng Song, Yanyan Prasad, Sanjay Zhang, Yan Zhao, Shihua Korean J Radiol Cardiovascular Imaging OBJECTIVE: Segmented cardiac cine magnetic resonance imaging (MRI) is the gold standard for cardiac ventricular volumetric assessment. In patients with difficulty in breath-holding or arrhythmia, this technique may generate images with inadequate quality for diagnosis. Real-time cardiac cine MRI has been developed to address this limitation. We aimed to assess the performance of retrospective electrocardiography-gated real-time cine MRI at 3T for left ventricular (LV) volume and mass measurement. MATERIALS AND METHODS: Fifty-one patients were consecutively enrolled. A series of short-axis cine images covering the entire left ventricle using both segmented and real-time balanced steady-state free precession cardiac cine MRI were obtained. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass were measured. The agreement and correlation of the parameters were assessed. Additionally, image quality was evaluated using European CMR Registry (Euro-CMR) score and structure visibility rating. RESULTS: In patients without difficulty in breath-holding or arrhythmia, no significant difference was found in Euro-CMR score between the two techniques (0.3 ± 0.7 vs. 0.3 ± 0.5, p > 0.05). Good agreements and correlations were found between the techniques for measuring EDV, ESV, EF, SV, and LV mass. In patients with difficulty in breath-holding or arrhythmia, segmented cine MRI had a significant higher Euro-CMR score (2.3 ± 1.2 vs. 0.4 ± 0.5, p < 0.001). CONCLUSION: Real-time cine MRI at 3T allowed the assessment of LV volume with high accuracy and showed a significantly better image quality compared to that of segmented cine MRI in patients with difficulty in breath-holding and arrhythmia. The Korean Society of Radiology 2019-01 2018-12-27 /pmc/articles/PMC6315079/ /pubmed/30627027 http://dx.doi.org/10.3348/kjr.2018.0243 Text en Copyright © 2019 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Cardiovascular Imaging Cui, Chen Yin, Gang Lu, Minjie Chen, Xiuyu Cheng, Sainan Li, Lu Yan, Weipeng Song, Yanyan Prasad, Sanjay Zhang, Yan Zhao, Shihua Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI |
title | Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI |
title_full | Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI |
title_fullStr | Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI |
title_full_unstemmed | Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI |
title_short | Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI |
title_sort | retrospective electrocardiography-gated real-time cardiac cine mri at 3t: comparison with conventional segmented cine mri |
topic | Cardiovascular Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6315079/ https://www.ncbi.nlm.nih.gov/pubmed/30627027 http://dx.doi.org/10.3348/kjr.2018.0243 |
work_keys_str_mv | AT cuichen retrospectiveelectrocardiographygatedrealtimecardiaccinemriat3tcomparisonwithconventionalsegmentedcinemri AT yingang retrospectiveelectrocardiographygatedrealtimecardiaccinemriat3tcomparisonwithconventionalsegmentedcinemri AT luminjie retrospectiveelectrocardiographygatedrealtimecardiaccinemriat3tcomparisonwithconventionalsegmentedcinemri AT chenxiuyu retrospectiveelectrocardiographygatedrealtimecardiaccinemriat3tcomparisonwithconventionalsegmentedcinemri AT chengsainan retrospectiveelectrocardiographygatedrealtimecardiaccinemriat3tcomparisonwithconventionalsegmentedcinemri AT lilu retrospectiveelectrocardiographygatedrealtimecardiaccinemriat3tcomparisonwithconventionalsegmentedcinemri AT yanweipeng retrospectiveelectrocardiographygatedrealtimecardiaccinemriat3tcomparisonwithconventionalsegmentedcinemri AT songyanyan retrospectiveelectrocardiographygatedrealtimecardiaccinemriat3tcomparisonwithconventionalsegmentedcinemri AT prasadsanjay retrospectiveelectrocardiographygatedrealtimecardiaccinemriat3tcomparisonwithconventionalsegmentedcinemri AT zhangyan retrospectiveelectrocardiographygatedrealtimecardiaccinemriat3tcomparisonwithconventionalsegmentedcinemri AT zhaoshihua retrospectiveelectrocardiographygatedrealtimecardiaccinemriat3tcomparisonwithconventionalsegmentedcinemri |