Data Integrity–Based Methodology and Checklist for Identifying Implementation Risks of Physiological Sensing in Mobile Health Projects: Quantitative and Qualitative Analysis
BACKGROUND: Mobile health (mHealth) technologies have the potential to bring health care closer to people with otherwise limited access to adequate health care. However, physiological monitoring using mobile medical sensors is not yet widely used as adding biomedical sensors to mHealth projects inhe...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6315242/ https://www.ncbi.nlm.nih.gov/pubmed/30552079 http://dx.doi.org/10.2196/11896 |
_version_ | 1783384248188665856 |
---|---|
author | Zhang, Jia Tüshaus, Laura Nuño Martínez, Néstor Moreo, Monica Verastegui, Hector Hartinger, Stella M Mäusezahl, Daniel Karlen, Walter |
author_facet | Zhang, Jia Tüshaus, Laura Nuño Martínez, Néstor Moreo, Monica Verastegui, Hector Hartinger, Stella M Mäusezahl, Daniel Karlen, Walter |
author_sort | Zhang, Jia |
collection | PubMed |
description | BACKGROUND: Mobile health (mHealth) technologies have the potential to bring health care closer to people with otherwise limited access to adequate health care. However, physiological monitoring using mobile medical sensors is not yet widely used as adding biomedical sensors to mHealth projects inherently introduces new challenges. Thus far, no methodology exists to systematically evaluate these implementation challenges and identify the related risks. OBJECTIVE: This study aimed to facilitate the implementation of mHealth initiatives with mobile physiological sensing in constrained health systems by developing a methodology to systematically evaluate potential challenges and implementation risks. METHODS: We performed a quantitative analysis of physiological data obtained from a randomized household intervention trial that implemented sensor-based mHealth tools (pulse oximetry combined with a respiratory rate assessment app) to monitor health outcomes of 317 children (aged 6-36 months) that were visited weekly by 1 of 9 field workers in a rural Peruvian setting. The analysis focused on data integrity such as data completeness and signal quality. In addition, we performed a qualitative analysis of pretrial usability and semistructured posttrial interviews with a subset of app users (7 field workers and 7 health care center staff members) focusing on data integrity and reasons for loss thereof. Common themes were identified using a content analysis approach. Risk factors of each theme were detailed and then generalized and expanded into a checklist by reviewing 8 mHealth projects from the literature. An expert panel evaluated the checklist during 2 iterations until agreement between the 5 experts was achieved. RESULTS: Pulse oximetry signals were recorded in 78.36% (12,098/15,439) of subject visits where tablets were used. Signal quality decreased for 1 and increased for 7 field workers over time (1 excluded). Usability issues were addressed and the workflow was improved. Users considered the app easy and logical to use. In the qualitative analysis, we constructed a thematic map with the causes of low data integrity. We sorted them into 5 main challenge categories: environment, technology, user skills, user motivation, and subject engagement. The obtained categories were translated into detailed risk factors and presented in the form of an actionable checklist to evaluate possible implementation risks. By visually inspecting the checklist, open issues and sources for potential risks can be easily identified. CONCLUSIONS: We developed a data integrity–based methodology to assess the potential challenges and risks of sensor-based mHealth projects. Aiming at improving data integrity, implementers can focus on the evaluation of environment, technology, user skills, user motivation, and subject engagement challenges. We provide a checklist to assist mHealth implementers with a structured evaluation protocol when planning and preparing projects. |
format | Online Article Text |
id | pubmed-6315242 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-63152422019-01-28 Data Integrity–Based Methodology and Checklist for Identifying Implementation Risks of Physiological Sensing in Mobile Health Projects: Quantitative and Qualitative Analysis Zhang, Jia Tüshaus, Laura Nuño Martínez, Néstor Moreo, Monica Verastegui, Hector Hartinger, Stella M Mäusezahl, Daniel Karlen, Walter JMIR Mhealth Uhealth Original Paper BACKGROUND: Mobile health (mHealth) technologies have the potential to bring health care closer to people with otherwise limited access to adequate health care. However, physiological monitoring using mobile medical sensors is not yet widely used as adding biomedical sensors to mHealth projects inherently introduces new challenges. Thus far, no methodology exists to systematically evaluate these implementation challenges and identify the related risks. OBJECTIVE: This study aimed to facilitate the implementation of mHealth initiatives with mobile physiological sensing in constrained health systems by developing a methodology to systematically evaluate potential challenges and implementation risks. METHODS: We performed a quantitative analysis of physiological data obtained from a randomized household intervention trial that implemented sensor-based mHealth tools (pulse oximetry combined with a respiratory rate assessment app) to monitor health outcomes of 317 children (aged 6-36 months) that were visited weekly by 1 of 9 field workers in a rural Peruvian setting. The analysis focused on data integrity such as data completeness and signal quality. In addition, we performed a qualitative analysis of pretrial usability and semistructured posttrial interviews with a subset of app users (7 field workers and 7 health care center staff members) focusing on data integrity and reasons for loss thereof. Common themes were identified using a content analysis approach. Risk factors of each theme were detailed and then generalized and expanded into a checklist by reviewing 8 mHealth projects from the literature. An expert panel evaluated the checklist during 2 iterations until agreement between the 5 experts was achieved. RESULTS: Pulse oximetry signals were recorded in 78.36% (12,098/15,439) of subject visits where tablets were used. Signal quality decreased for 1 and increased for 7 field workers over time (1 excluded). Usability issues were addressed and the workflow was improved. Users considered the app easy and logical to use. In the qualitative analysis, we constructed a thematic map with the causes of low data integrity. We sorted them into 5 main challenge categories: environment, technology, user skills, user motivation, and subject engagement. The obtained categories were translated into detailed risk factors and presented in the form of an actionable checklist to evaluate possible implementation risks. By visually inspecting the checklist, open issues and sources for potential risks can be easily identified. CONCLUSIONS: We developed a data integrity–based methodology to assess the potential challenges and risks of sensor-based mHealth projects. Aiming at improving data integrity, implementers can focus on the evaluation of environment, technology, user skills, user motivation, and subject engagement challenges. We provide a checklist to assist mHealth implementers with a structured evaluation protocol when planning and preparing projects. JMIR Publications 2018-12-14 /pmc/articles/PMC6315242/ /pubmed/30552079 http://dx.doi.org/10.2196/11896 Text en ©Jia Zhang, Laura Tüshaus, Néstor Nuño Martínez, Monica Moreo, Hector Verastegui, Stella M Hartinger, Daniel Mäusezahl, Walter Karlen. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 14.12.2018. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mhealth and uhealth, is properly cited. The complete bibliographic information, a link to the original publication on http://mhealth.jmir.org/, as well as this copyright and license information must be included. |
spellingShingle | Original Paper Zhang, Jia Tüshaus, Laura Nuño Martínez, Néstor Moreo, Monica Verastegui, Hector Hartinger, Stella M Mäusezahl, Daniel Karlen, Walter Data Integrity–Based Methodology and Checklist for Identifying Implementation Risks of Physiological Sensing in Mobile Health Projects: Quantitative and Qualitative Analysis |
title | Data Integrity–Based Methodology and Checklist for Identifying Implementation Risks of Physiological Sensing in Mobile Health Projects: Quantitative and Qualitative Analysis |
title_full | Data Integrity–Based Methodology and Checklist for Identifying Implementation Risks of Physiological Sensing in Mobile Health Projects: Quantitative and Qualitative Analysis |
title_fullStr | Data Integrity–Based Methodology and Checklist for Identifying Implementation Risks of Physiological Sensing in Mobile Health Projects: Quantitative and Qualitative Analysis |
title_full_unstemmed | Data Integrity–Based Methodology and Checklist for Identifying Implementation Risks of Physiological Sensing in Mobile Health Projects: Quantitative and Qualitative Analysis |
title_short | Data Integrity–Based Methodology and Checklist for Identifying Implementation Risks of Physiological Sensing in Mobile Health Projects: Quantitative and Qualitative Analysis |
title_sort | data integrity–based methodology and checklist for identifying implementation risks of physiological sensing in mobile health projects: quantitative and qualitative analysis |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6315242/ https://www.ncbi.nlm.nih.gov/pubmed/30552079 http://dx.doi.org/10.2196/11896 |
work_keys_str_mv | AT zhangjia dataintegritybasedmethodologyandchecklistforidentifyingimplementationrisksofphysiologicalsensinginmobilehealthprojectsquantitativeandqualitativeanalysis AT tushauslaura dataintegritybasedmethodologyandchecklistforidentifyingimplementationrisksofphysiologicalsensinginmobilehealthprojectsquantitativeandqualitativeanalysis AT nunomartineznestor dataintegritybasedmethodologyandchecklistforidentifyingimplementationrisksofphysiologicalsensinginmobilehealthprojectsquantitativeandqualitativeanalysis AT moreomonica dataintegritybasedmethodologyandchecklistforidentifyingimplementationrisksofphysiologicalsensinginmobilehealthprojectsquantitativeandqualitativeanalysis AT verasteguihector dataintegritybasedmethodologyandchecklistforidentifyingimplementationrisksofphysiologicalsensinginmobilehealthprojectsquantitativeandqualitativeanalysis AT hartingerstellam dataintegritybasedmethodologyandchecklistforidentifyingimplementationrisksofphysiologicalsensinginmobilehealthprojectsquantitativeandqualitativeanalysis AT mausezahldaniel dataintegritybasedmethodologyandchecklistforidentifyingimplementationrisksofphysiologicalsensinginmobilehealthprojectsquantitativeandqualitativeanalysis AT karlenwalter dataintegritybasedmethodologyandchecklistforidentifyingimplementationrisksofphysiologicalsensinginmobilehealthprojectsquantitativeandqualitativeanalysis |