Cargando…
Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer
The traditional silicon-based micro-electro-mechanical systems (MEMS) safety and arming (S&A) device fuze cannot isolate abnormal outputs in the detonation environment, which creates hazards for personnel. To address this problem, we report the design of a MEMS S&A device with integrated sil...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6315855/ https://www.ncbi.nlm.nih.gov/pubmed/30544671 http://dx.doi.org/10.3390/mi9120652 |
_version_ | 1783384393270689792 |
---|---|
author | Feng, Hengzhen Lou, Wenzhong Wang, Dakui Zheng, Fuquan |
author_facet | Feng, Hengzhen Lou, Wenzhong Wang, Dakui Zheng, Fuquan |
author_sort | Feng, Hengzhen |
collection | PubMed |
description | The traditional silicon-based micro-electro-mechanical systems (MEMS) safety and arming (S&A) device fuze cannot isolate abnormal outputs in the detonation environment, which creates hazards for personnel. To address this problem, we report the design of a MEMS S&A device with integrated silver, copper, nickel and polyimide (PI) films, which is based on the principle of a MEMS S&A device and uses copper azide as the primer. The MEMS S&A device was optimized using theoretical calculations of the explosion suppression mechanism performance in a detonation field, where the theoretical model was verified by dynamic simulation (LS-Dyna). Silicon-based MEMS processing technology was used to integrate the MEMS S&A device with energy-absorbing materials, and the device performance was compared in detonation tests. Silicon-based MEMS S&A devices with silver, copper, nickel, and PI (100-μm-thick) achieved a reliable explosion suppression mechanism capability when exposed to a detonation wave. The residual stress was measured using Raman microscopy, and the PI film exhibited the best explosion suppression mechanism performance of the four materials. A reliability test to determine the maximum explosion suppression mechanism dose for a MEMS S&A device attached to a PI film (100-μm-thick) showed that the maximum amount of primer needed for the effective explosion suppression mechanism capability on the MEMS S&A device was 0.45 mg. |
format | Online Article Text |
id | pubmed-6315855 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-63158552019-01-10 Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer Feng, Hengzhen Lou, Wenzhong Wang, Dakui Zheng, Fuquan Micromachines (Basel) Article The traditional silicon-based micro-electro-mechanical systems (MEMS) safety and arming (S&A) device fuze cannot isolate abnormal outputs in the detonation environment, which creates hazards for personnel. To address this problem, we report the design of a MEMS S&A device with integrated silver, copper, nickel and polyimide (PI) films, which is based on the principle of a MEMS S&A device and uses copper azide as the primer. The MEMS S&A device was optimized using theoretical calculations of the explosion suppression mechanism performance in a detonation field, where the theoretical model was verified by dynamic simulation (LS-Dyna). Silicon-based MEMS processing technology was used to integrate the MEMS S&A device with energy-absorbing materials, and the device performance was compared in detonation tests. Silicon-based MEMS S&A devices with silver, copper, nickel, and PI (100-μm-thick) achieved a reliable explosion suppression mechanism capability when exposed to a detonation wave. The residual stress was measured using Raman microscopy, and the PI film exhibited the best explosion suppression mechanism performance of the four materials. A reliability test to determine the maximum explosion suppression mechanism dose for a MEMS S&A device attached to a PI film (100-μm-thick) showed that the maximum amount of primer needed for the effective explosion suppression mechanism capability on the MEMS S&A device was 0.45 mg. MDPI 2018-12-10 /pmc/articles/PMC6315855/ /pubmed/30544671 http://dx.doi.org/10.3390/mi9120652 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Feng, Hengzhen Lou, Wenzhong Wang, Dakui Zheng, Fuquan Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer |
title | Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer |
title_full | Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer |
title_fullStr | Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer |
title_full_unstemmed | Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer |
title_short | Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer |
title_sort | explosion suppression mechanism characteristics of mems s&a device with in situ synthetic primer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6315855/ https://www.ncbi.nlm.nih.gov/pubmed/30544671 http://dx.doi.org/10.3390/mi9120652 |
work_keys_str_mv | AT fenghengzhen explosionsuppressionmechanismcharacteristicsofmemssadevicewithinsitusyntheticprimer AT louwenzhong explosionsuppressionmechanismcharacteristicsofmemssadevicewithinsitusyntheticprimer AT wangdakui explosionsuppressionmechanismcharacteristicsofmemssadevicewithinsitusyntheticprimer AT zhengfuquan explosionsuppressionmechanismcharacteristicsofmemssadevicewithinsitusyntheticprimer |