Cargando…

Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer

The traditional silicon-based micro-electro-mechanical systems (MEMS) safety and arming (S&A) device fuze cannot isolate abnormal outputs in the detonation environment, which creates hazards for personnel. To address this problem, we report the design of a MEMS S&A device with integrated sil...

Descripción completa

Detalles Bibliográficos
Autores principales: Feng, Hengzhen, Lou, Wenzhong, Wang, Dakui, Zheng, Fuquan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6315855/
https://www.ncbi.nlm.nih.gov/pubmed/30544671
http://dx.doi.org/10.3390/mi9120652
_version_ 1783384393270689792
author Feng, Hengzhen
Lou, Wenzhong
Wang, Dakui
Zheng, Fuquan
author_facet Feng, Hengzhen
Lou, Wenzhong
Wang, Dakui
Zheng, Fuquan
author_sort Feng, Hengzhen
collection PubMed
description The traditional silicon-based micro-electro-mechanical systems (MEMS) safety and arming (S&A) device fuze cannot isolate abnormal outputs in the detonation environment, which creates hazards for personnel. To address this problem, we report the design of a MEMS S&A device with integrated silver, copper, nickel and polyimide (PI) films, which is based on the principle of a MEMS S&A device and uses copper azide as the primer. The MEMS S&A device was optimized using theoretical calculations of the explosion suppression mechanism performance in a detonation field, where the theoretical model was verified by dynamic simulation (LS-Dyna). Silicon-based MEMS processing technology was used to integrate the MEMS S&A device with energy-absorbing materials, and the device performance was compared in detonation tests. Silicon-based MEMS S&A devices with silver, copper, nickel, and PI (100-μm-thick) achieved a reliable explosion suppression mechanism capability when exposed to a detonation wave. The residual stress was measured using Raman microscopy, and the PI film exhibited the best explosion suppression mechanism performance of the four materials. A reliability test to determine the maximum explosion suppression mechanism dose for a MEMS S&A device attached to a PI film (100-μm-thick) showed that the maximum amount of primer needed for the effective explosion suppression mechanism capability on the MEMS S&A device was 0.45 mg.
format Online
Article
Text
id pubmed-6315855
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-63158552019-01-10 Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer Feng, Hengzhen Lou, Wenzhong Wang, Dakui Zheng, Fuquan Micromachines (Basel) Article The traditional silicon-based micro-electro-mechanical systems (MEMS) safety and arming (S&A) device fuze cannot isolate abnormal outputs in the detonation environment, which creates hazards for personnel. To address this problem, we report the design of a MEMS S&A device with integrated silver, copper, nickel and polyimide (PI) films, which is based on the principle of a MEMS S&A device and uses copper azide as the primer. The MEMS S&A device was optimized using theoretical calculations of the explosion suppression mechanism performance in a detonation field, where the theoretical model was verified by dynamic simulation (LS-Dyna). Silicon-based MEMS processing technology was used to integrate the MEMS S&A device with energy-absorbing materials, and the device performance was compared in detonation tests. Silicon-based MEMS S&A devices with silver, copper, nickel, and PI (100-μm-thick) achieved a reliable explosion suppression mechanism capability when exposed to a detonation wave. The residual stress was measured using Raman microscopy, and the PI film exhibited the best explosion suppression mechanism performance of the four materials. A reliability test to determine the maximum explosion suppression mechanism dose for a MEMS S&A device attached to a PI film (100-μm-thick) showed that the maximum amount of primer needed for the effective explosion suppression mechanism capability on the MEMS S&A device was 0.45 mg. MDPI 2018-12-10 /pmc/articles/PMC6315855/ /pubmed/30544671 http://dx.doi.org/10.3390/mi9120652 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Feng, Hengzhen
Lou, Wenzhong
Wang, Dakui
Zheng, Fuquan
Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer
title Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer
title_full Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer
title_fullStr Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer
title_full_unstemmed Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer
title_short Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer
title_sort explosion suppression mechanism characteristics of mems s&a device with in situ synthetic primer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6315855/
https://www.ncbi.nlm.nih.gov/pubmed/30544671
http://dx.doi.org/10.3390/mi9120652
work_keys_str_mv AT fenghengzhen explosionsuppressionmechanismcharacteristicsofmemssadevicewithinsitusyntheticprimer
AT louwenzhong explosionsuppressionmechanismcharacteristicsofmemssadevicewithinsitusyntheticprimer
AT wangdakui explosionsuppressionmechanismcharacteristicsofmemssadevicewithinsitusyntheticprimer
AT zhengfuquan explosionsuppressionmechanismcharacteristicsofmemssadevicewithinsitusyntheticprimer