Cargando…
Explosion Suppression Mechanism Characteristics of MEMS S&A Device With In Situ Synthetic Primer
The traditional silicon-based micro-electro-mechanical systems (MEMS) safety and arming (S&A) device fuze cannot isolate abnormal outputs in the detonation environment, which creates hazards for personnel. To address this problem, we report the design of a MEMS S&A device with integrated sil...
Autores principales: | Feng, Hengzhen, Lou, Wenzhong, Wang, Dakui, Zheng, Fuquan |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6315855/ https://www.ncbi.nlm.nih.gov/pubmed/30544671 http://dx.doi.org/10.3390/mi9120652 |
Ejemplares similares
-
Study on Characteristics of Electromagnetic Coil Used in MEMS Safety and Arming Device
por: Sun, Yi, et al.
Publicado: (2020) -
Research on MEMS Solid-State Fuse Logic Control Chip Based on Electrical Explosion Effect
por: Su, Wenting, et al.
Publicado: (2023) -
Research on the Application of Microcast Electromagnetic Coil in an Si MEMS Bistable Recoverable Safety and Arming Device
por: Lv, Sining, et al.
Publicado: (2023) -
Design of High-Reliability Micro Safety and Arming Devices for a Small Caliber Projectile
por: Wang, Dakui, et al.
Publicado: (2017) -
MEMS Device for Quantitative In Situ Mechanical Testing in Electron Microscope
por: Wang, Xiaodong, et al.
Publicado: (2017)