Evaluation of Continuous Lactate Monitoring Systems within a Heparinized In Vivo Porcine Model Intravenously and Subcutaneously

We present an animal model used to evaluate the in vivo performance of electrochemical amperometric continuous lactate sensors compared to blood gas instruments. Electrochemical lactate sensors were fabricated, placed into 5 Fr central venous catheters (CVCs), and paired with wireless potentiostat d...

Descripción completa

Detalles Bibliográficos
Autores principales: Wolf, Alexander, Renehan, Kevin, Ho, Kenneth K. Y., Carr, Benjamin D., Chen, Chieh V., Cornell, Marie S., Ye, Minyi, Rojas-Peña, Alvaro, Chen, Hao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6316727/
https://www.ncbi.nlm.nih.gov/pubmed/30518105
http://dx.doi.org/10.3390/bios8040122
_version_ 1783384598645833728
author Wolf, Alexander
Renehan, Kevin
Ho, Kenneth K. Y.
Carr, Benjamin D.
Chen, Chieh V.
Cornell, Marie S.
Ye, Minyi
Rojas-Peña, Alvaro
Chen, Hao
author_facet Wolf, Alexander
Renehan, Kevin
Ho, Kenneth K. Y.
Carr, Benjamin D.
Chen, Chieh V.
Cornell, Marie S.
Ye, Minyi
Rojas-Peña, Alvaro
Chen, Hao
author_sort Wolf, Alexander
collection PubMed
description We present an animal model used to evaluate the in vivo performance of electrochemical amperometric continuous lactate sensors compared to blood gas instruments. Electrochemical lactate sensors were fabricated, placed into 5 Fr central venous catheters (CVCs), and paired with wireless potentiostat devices. Following in vivo evaluation and calibration, sensors were placed within the jugular and femoral veins of a porcine subject as a preliminary assessment of in vivo measurement accuracy. The mobile electronic circuit potentiostat devices supplied the operational voltage for the sensors, measured the resultant steady-state current, and recorded the sensor response values in internal memory storages. An in vivo time trace of implanted intravenous (IV) sensors demonstrated lactate values that correlated well with the discrete measurements of blood samples on a benchtop point-of-care sensor-based instrument. Currents measured continuously from the implanted lactate sensors over 10 h were converted into lactate concentration values through use of a two-point in vivo calibration. Study shows that intravenously implanted sensors had more accurate readings, faster peak-reaching rates, and shorter peak-detection times compared to subcutaneously placed sensors. IV implanted and subcutaneously placed sensors closer to the upper body (in this case neck) showed faster response rates and more accurate measurements compared to those implanted in the lower portion of the porcine model. This study represents an important milestone not only towards continuous lactate monitoring for early diagnosis and intervention in neonatal patients with congenital heart disease undergoing cardiopulmonary bypass surgeries, but also in the intervention of critical ill patients in the Intensive Care Units or during complex surgical procedures.
format Online
Article
Text
id pubmed-6316727
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-63167272019-01-09 Evaluation of Continuous Lactate Monitoring Systems within a Heparinized In Vivo Porcine Model Intravenously and Subcutaneously Wolf, Alexander Renehan, Kevin Ho, Kenneth K. Y. Carr, Benjamin D. Chen, Chieh V. Cornell, Marie S. Ye, Minyi Rojas-Peña, Alvaro Chen, Hao Biosensors (Basel) Article We present an animal model used to evaluate the in vivo performance of electrochemical amperometric continuous lactate sensors compared to blood gas instruments. Electrochemical lactate sensors were fabricated, placed into 5 Fr central venous catheters (CVCs), and paired with wireless potentiostat devices. Following in vivo evaluation and calibration, sensors were placed within the jugular and femoral veins of a porcine subject as a preliminary assessment of in vivo measurement accuracy. The mobile electronic circuit potentiostat devices supplied the operational voltage for the sensors, measured the resultant steady-state current, and recorded the sensor response values in internal memory storages. An in vivo time trace of implanted intravenous (IV) sensors demonstrated lactate values that correlated well with the discrete measurements of blood samples on a benchtop point-of-care sensor-based instrument. Currents measured continuously from the implanted lactate sensors over 10 h were converted into lactate concentration values through use of a two-point in vivo calibration. Study shows that intravenously implanted sensors had more accurate readings, faster peak-reaching rates, and shorter peak-detection times compared to subcutaneously placed sensors. IV implanted and subcutaneously placed sensors closer to the upper body (in this case neck) showed faster response rates and more accurate measurements compared to those implanted in the lower portion of the porcine model. This study represents an important milestone not only towards continuous lactate monitoring for early diagnosis and intervention in neonatal patients with congenital heart disease undergoing cardiopulmonary bypass surgeries, but also in the intervention of critical ill patients in the Intensive Care Units or during complex surgical procedures. MDPI 2018-12-04 /pmc/articles/PMC6316727/ /pubmed/30518105 http://dx.doi.org/10.3390/bios8040122 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wolf, Alexander
Renehan, Kevin
Ho, Kenneth K. Y.
Carr, Benjamin D.
Chen, Chieh V.
Cornell, Marie S.
Ye, Minyi
Rojas-Peña, Alvaro
Chen, Hao
Evaluation of Continuous Lactate Monitoring Systems within a Heparinized In Vivo Porcine Model Intravenously and Subcutaneously
title Evaluation of Continuous Lactate Monitoring Systems within a Heparinized In Vivo Porcine Model Intravenously and Subcutaneously
title_full Evaluation of Continuous Lactate Monitoring Systems within a Heparinized In Vivo Porcine Model Intravenously and Subcutaneously
title_fullStr Evaluation of Continuous Lactate Monitoring Systems within a Heparinized In Vivo Porcine Model Intravenously and Subcutaneously
title_full_unstemmed Evaluation of Continuous Lactate Monitoring Systems within a Heparinized In Vivo Porcine Model Intravenously and Subcutaneously
title_short Evaluation of Continuous Lactate Monitoring Systems within a Heparinized In Vivo Porcine Model Intravenously and Subcutaneously
title_sort evaluation of continuous lactate monitoring systems within a heparinized in vivo porcine model intravenously and subcutaneously
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6316727/
https://www.ncbi.nlm.nih.gov/pubmed/30518105
http://dx.doi.org/10.3390/bios8040122
work_keys_str_mv AT wolfalexander evaluationofcontinuouslactatemonitoringsystemswithinaheparinizedinvivoporcinemodelintravenouslyandsubcutaneously
AT renehankevin evaluationofcontinuouslactatemonitoringsystemswithinaheparinizedinvivoporcinemodelintravenouslyandsubcutaneously
AT hokennethky evaluationofcontinuouslactatemonitoringsystemswithinaheparinizedinvivoporcinemodelintravenouslyandsubcutaneously
AT carrbenjamind evaluationofcontinuouslactatemonitoringsystemswithinaheparinizedinvivoporcinemodelintravenouslyandsubcutaneously
AT chenchiehv evaluationofcontinuouslactatemonitoringsystemswithinaheparinizedinvivoporcinemodelintravenouslyandsubcutaneously
AT cornellmaries evaluationofcontinuouslactatemonitoringsystemswithinaheparinizedinvivoporcinemodelintravenouslyandsubcutaneously
AT yeminyi evaluationofcontinuouslactatemonitoringsystemswithinaheparinizedinvivoporcinemodelintravenouslyandsubcutaneously
AT rojaspenaalvaro evaluationofcontinuouslactatemonitoringsystemswithinaheparinizedinvivoporcinemodelintravenouslyandsubcutaneously
AT chenhao evaluationofcontinuouslactatemonitoringsystemswithinaheparinizedinvivoporcinemodelintravenouslyandsubcutaneously