Cargando…

Active Image-Assisted Food Records in Comparison to Regular Food Records: A Validation Study against Doubly Labeled Water in 12-Month-Old Infants

Overreporting of dietary intake in infants is a problem when using food records (FR), distorting possible relationships between diet and health outcomes. Image-assisted dietary assessment may improve the accuracy, but to date, evaluation in the pediatric setting is limited. The aim of the study was...

Descripción completa

Detalles Bibliográficos
Autores principales: Johansson, Ulrica, Venables, Michelle, Öhlund, Inger, Lind, Torbjörn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6316799/
https://www.ncbi.nlm.nih.gov/pubmed/30518042
http://dx.doi.org/10.3390/nu10121904
_version_ 1783384615433535488
author Johansson, Ulrica
Venables, Michelle
Öhlund, Inger
Lind, Torbjörn
author_facet Johansson, Ulrica
Venables, Michelle
Öhlund, Inger
Lind, Torbjörn
author_sort Johansson, Ulrica
collection PubMed
description Overreporting of dietary intake in infants is a problem when using food records (FR), distorting possible relationships between diet and health outcomes. Image-assisted dietary assessment may improve the accuracy, but to date, evaluation in the pediatric setting is limited. The aim of the study was to compare macronutrient and energy intake by using an active image-assisted five-day FR against a regular five-day FR, and to validate image-assistance with total energy expenditure (TEE), was measured using doubly labeled water. Participants in this validation study were 22 healthy infants randomly selected from the control group of a larger, randomized intervention trial. The parents reported the infants’ dietary intake, and supplied images of main course meals taken from standardized flat-surfaced plates before and after eating episodes. Energy and nutrient intakes were calculated separately using regular FR and image-assisted FRs. The mean (± standard deviations) energy intake (EI) was 3902 ± 476 kJ/day from the regular FR, and 3905 ± 476 kJ/day from the FR using active image-assistance. The mean EI from main-course meals when image-assistance was used did not differ (1.7 ± 55 kJ, p = 0.89) compared to regular FRs nor did the intake of macronutrients. Compared to TEE, image-assisted FR overestimated EI by 10%. Without validation, commercially available software to aid in the volume estimations, food item identification, and automation of the image processing, image-assisted methods remain a more costly and burdensome alternative to regular FRs in infants. The image-assisted method did, however, identify leftovers better than did regular FR, where such information is usually not readily available.
format Online
Article
Text
id pubmed-6316799
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-63167992019-01-08 Active Image-Assisted Food Records in Comparison to Regular Food Records: A Validation Study against Doubly Labeled Water in 12-Month-Old Infants Johansson, Ulrica Venables, Michelle Öhlund, Inger Lind, Torbjörn Nutrients Article Overreporting of dietary intake in infants is a problem when using food records (FR), distorting possible relationships between diet and health outcomes. Image-assisted dietary assessment may improve the accuracy, but to date, evaluation in the pediatric setting is limited. The aim of the study was to compare macronutrient and energy intake by using an active image-assisted five-day FR against a regular five-day FR, and to validate image-assistance with total energy expenditure (TEE), was measured using doubly labeled water. Participants in this validation study were 22 healthy infants randomly selected from the control group of a larger, randomized intervention trial. The parents reported the infants’ dietary intake, and supplied images of main course meals taken from standardized flat-surfaced plates before and after eating episodes. Energy and nutrient intakes were calculated separately using regular FR and image-assisted FRs. The mean (± standard deviations) energy intake (EI) was 3902 ± 476 kJ/day from the regular FR, and 3905 ± 476 kJ/day from the FR using active image-assistance. The mean EI from main-course meals when image-assistance was used did not differ (1.7 ± 55 kJ, p = 0.89) compared to regular FRs nor did the intake of macronutrients. Compared to TEE, image-assisted FR overestimated EI by 10%. Without validation, commercially available software to aid in the volume estimations, food item identification, and automation of the image processing, image-assisted methods remain a more costly and burdensome alternative to regular FRs in infants. The image-assisted method did, however, identify leftovers better than did regular FR, where such information is usually not readily available. MDPI 2018-12-04 /pmc/articles/PMC6316799/ /pubmed/30518042 http://dx.doi.org/10.3390/nu10121904 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Johansson, Ulrica
Venables, Michelle
Öhlund, Inger
Lind, Torbjörn
Active Image-Assisted Food Records in Comparison to Regular Food Records: A Validation Study against Doubly Labeled Water in 12-Month-Old Infants
title Active Image-Assisted Food Records in Comparison to Regular Food Records: A Validation Study against Doubly Labeled Water in 12-Month-Old Infants
title_full Active Image-Assisted Food Records in Comparison to Regular Food Records: A Validation Study against Doubly Labeled Water in 12-Month-Old Infants
title_fullStr Active Image-Assisted Food Records in Comparison to Regular Food Records: A Validation Study against Doubly Labeled Water in 12-Month-Old Infants
title_full_unstemmed Active Image-Assisted Food Records in Comparison to Regular Food Records: A Validation Study against Doubly Labeled Water in 12-Month-Old Infants
title_short Active Image-Assisted Food Records in Comparison to Regular Food Records: A Validation Study against Doubly Labeled Water in 12-Month-Old Infants
title_sort active image-assisted food records in comparison to regular food records: a validation study against doubly labeled water in 12-month-old infants
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6316799/
https://www.ncbi.nlm.nih.gov/pubmed/30518042
http://dx.doi.org/10.3390/nu10121904
work_keys_str_mv AT johanssonulrica activeimageassistedfoodrecordsincomparisontoregularfoodrecordsavalidationstudyagainstdoublylabeledwaterin12montholdinfants
AT venablesmichelle activeimageassistedfoodrecordsincomparisontoregularfoodrecordsavalidationstudyagainstdoublylabeledwaterin12montholdinfants
AT ohlundinger activeimageassistedfoodrecordsincomparisontoregularfoodrecordsavalidationstudyagainstdoublylabeledwaterin12montholdinfants
AT lindtorbjorn activeimageassistedfoodrecordsincomparisontoregularfoodrecordsavalidationstudyagainstdoublylabeledwaterin12montholdinfants