Cargando…

Diagnostic Performance of Digital Breast Tomosynthesis for Breast Suspicious Calcifications From Various Populations: A Comparison With Full-field Digital Mammography

The diagnostic performance difference between digital breast tomosynthesis (DBT) and conventional full-field digital mammography (FFDM) for breast suspicious calcifications from various populations is unclear. The objective of this study is to determine whether DBT exhibits the diagnostic advantage...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Juntao, Zhang, Hengwei, Jiang, Hui, Guo, Xuhui, Zhang, Yinli, Qi, Dan, Guan, Jitian, Liu, Zhenzhen, Wu, Erxi, Luo, Suxia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Research Network of Computational and Structural Biotechnology 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6317146/
https://www.ncbi.nlm.nih.gov/pubmed/30622686
http://dx.doi.org/10.1016/j.csbj.2018.12.004
_version_ 1783384692265844736
author Li, Juntao
Zhang, Hengwei
Jiang, Hui
Guo, Xuhui
Zhang, Yinli
Qi, Dan
Guan, Jitian
Liu, Zhenzhen
Wu, Erxi
Luo, Suxia
author_facet Li, Juntao
Zhang, Hengwei
Jiang, Hui
Guo, Xuhui
Zhang, Yinli
Qi, Dan
Guan, Jitian
Liu, Zhenzhen
Wu, Erxi
Luo, Suxia
author_sort Li, Juntao
collection PubMed
description The diagnostic performance difference between digital breast tomosynthesis (DBT) and conventional full-field digital mammography (FFDM) for breast suspicious calcifications from various populations is unclear. The objective of this study is to determine whether DBT exhibits the diagnostic advantage for breast suspicious calcifications from various populations compared with FFDM. Three hundred and five patients were enrolled (of which seven patients with bilateral lesions) and 312 breasts images were retrospectively analyzed by three radiologists independently. The postoperative pathology of breast calcifications was the gold standard. Breast cancer was diagnosed utilizing DBT and FFDM with sensitivities of 92.9% and 88.8%, specificities of 87.9% and 75.2%, positive predictive values of 77.8% and 62.1%, negative predictive values of 96.4% and 93.6%, respectively. DBT exhibited significantly higher diagnostic accuracy for benign calcifications compared with FFDM (87.9% vs 75.2%), and no advantage in the diagnosis of malignant calcifications. DBT diagnostic accuracy was notably higher than FFDM in premenopausal (88.4% vs 78.8%), postmenopausal (90.2% vs 77.2%), and dense breast cases (89.4% vs 81.9%). There was no significant difference in non-dense breast cases. In our study, DBT exhibited a superior advantage in dense breasts and benign calcifications cases compared to FFDM, while no advantage was observed in non-dense breasts or malignant calcifications cases. Thus, in the breast cancer screening for young women with dense breasts, DBT may be recommended for accurate diagnosis. Our findings may assist the clinicians in applying the optimal techniques for different patients and provide a theoretical basis for the update of breast cancer screening guideline.
format Online
Article
Text
id pubmed-6317146
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Research Network of Computational and Structural Biotechnology
record_format MEDLINE/PubMed
spelling pubmed-63171462019-01-08 Diagnostic Performance of Digital Breast Tomosynthesis for Breast Suspicious Calcifications From Various Populations: A Comparison With Full-field Digital Mammography Li, Juntao Zhang, Hengwei Jiang, Hui Guo, Xuhui Zhang, Yinli Qi, Dan Guan, Jitian Liu, Zhenzhen Wu, Erxi Luo, Suxia Comput Struct Biotechnol J Research Article The diagnostic performance difference between digital breast tomosynthesis (DBT) and conventional full-field digital mammography (FFDM) for breast suspicious calcifications from various populations is unclear. The objective of this study is to determine whether DBT exhibits the diagnostic advantage for breast suspicious calcifications from various populations compared with FFDM. Three hundred and five patients were enrolled (of which seven patients with bilateral lesions) and 312 breasts images were retrospectively analyzed by three radiologists independently. The postoperative pathology of breast calcifications was the gold standard. Breast cancer was diagnosed utilizing DBT and FFDM with sensitivities of 92.9% and 88.8%, specificities of 87.9% and 75.2%, positive predictive values of 77.8% and 62.1%, negative predictive values of 96.4% and 93.6%, respectively. DBT exhibited significantly higher diagnostic accuracy for benign calcifications compared with FFDM (87.9% vs 75.2%), and no advantage in the diagnosis of malignant calcifications. DBT diagnostic accuracy was notably higher than FFDM in premenopausal (88.4% vs 78.8%), postmenopausal (90.2% vs 77.2%), and dense breast cases (89.4% vs 81.9%). There was no significant difference in non-dense breast cases. In our study, DBT exhibited a superior advantage in dense breasts and benign calcifications cases compared to FFDM, while no advantage was observed in non-dense breasts or malignant calcifications cases. Thus, in the breast cancer screening for young women with dense breasts, DBT may be recommended for accurate diagnosis. Our findings may assist the clinicians in applying the optimal techniques for different patients and provide a theoretical basis for the update of breast cancer screening guideline. Research Network of Computational and Structural Biotechnology 2018-12-20 /pmc/articles/PMC6317146/ /pubmed/30622686 http://dx.doi.org/10.1016/j.csbj.2018.12.004 Text en © 2018 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Research Article
Li, Juntao
Zhang, Hengwei
Jiang, Hui
Guo, Xuhui
Zhang, Yinli
Qi, Dan
Guan, Jitian
Liu, Zhenzhen
Wu, Erxi
Luo, Suxia
Diagnostic Performance of Digital Breast Tomosynthesis for Breast Suspicious Calcifications From Various Populations: A Comparison With Full-field Digital Mammography
title Diagnostic Performance of Digital Breast Tomosynthesis for Breast Suspicious Calcifications From Various Populations: A Comparison With Full-field Digital Mammography
title_full Diagnostic Performance of Digital Breast Tomosynthesis for Breast Suspicious Calcifications From Various Populations: A Comparison With Full-field Digital Mammography
title_fullStr Diagnostic Performance of Digital Breast Tomosynthesis for Breast Suspicious Calcifications From Various Populations: A Comparison With Full-field Digital Mammography
title_full_unstemmed Diagnostic Performance of Digital Breast Tomosynthesis for Breast Suspicious Calcifications From Various Populations: A Comparison With Full-field Digital Mammography
title_short Diagnostic Performance of Digital Breast Tomosynthesis for Breast Suspicious Calcifications From Various Populations: A Comparison With Full-field Digital Mammography
title_sort diagnostic performance of digital breast tomosynthesis for breast suspicious calcifications from various populations: a comparison with full-field digital mammography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6317146/
https://www.ncbi.nlm.nih.gov/pubmed/30622686
http://dx.doi.org/10.1016/j.csbj.2018.12.004
work_keys_str_mv AT lijuntao diagnosticperformanceofdigitalbreasttomosynthesisforbreastsuspiciouscalcificationsfromvariouspopulationsacomparisonwithfullfielddigitalmammography
AT zhanghengwei diagnosticperformanceofdigitalbreasttomosynthesisforbreastsuspiciouscalcificationsfromvariouspopulationsacomparisonwithfullfielddigitalmammography
AT jianghui diagnosticperformanceofdigitalbreasttomosynthesisforbreastsuspiciouscalcificationsfromvariouspopulationsacomparisonwithfullfielddigitalmammography
AT guoxuhui diagnosticperformanceofdigitalbreasttomosynthesisforbreastsuspiciouscalcificationsfromvariouspopulationsacomparisonwithfullfielddigitalmammography
AT zhangyinli diagnosticperformanceofdigitalbreasttomosynthesisforbreastsuspiciouscalcificationsfromvariouspopulationsacomparisonwithfullfielddigitalmammography
AT qidan diagnosticperformanceofdigitalbreasttomosynthesisforbreastsuspiciouscalcificationsfromvariouspopulationsacomparisonwithfullfielddigitalmammography
AT guanjitian diagnosticperformanceofdigitalbreasttomosynthesisforbreastsuspiciouscalcificationsfromvariouspopulationsacomparisonwithfullfielddigitalmammography
AT liuzhenzhen diagnosticperformanceofdigitalbreasttomosynthesisforbreastsuspiciouscalcificationsfromvariouspopulationsacomparisonwithfullfielddigitalmammography
AT wuerxi diagnosticperformanceofdigitalbreasttomosynthesisforbreastsuspiciouscalcificationsfromvariouspopulationsacomparisonwithfullfielddigitalmammography
AT luosuxia diagnosticperformanceofdigitalbreasttomosynthesisforbreastsuspiciouscalcificationsfromvariouspopulationsacomparisonwithfullfielddigitalmammography