Cargando…

A compact pulsatile simulator based on cam-follower mechanism for generating radial pulse waveforms

BACKGROUND: There exists a growing need for a cost-effective, reliable, and portable pulsation simulator that can generate a wide variety of pulses depending on age and cardiovascular disease. For constructing compact pulsation simulator, this study proposes to use a pneumatic actuator based on cam-...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Tae-Heon, Jo, Gwanghyun, Koo, Jeong-Hoi, Woo, Sam-Yong, Kim, Jaeuk U., Kim, Young-Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6317228/
https://www.ncbi.nlm.nih.gov/pubmed/30602383
http://dx.doi.org/10.1186/s12938-018-0620-3
_version_ 1783384711395016704
author Yang, Tae-Heon
Jo, Gwanghyun
Koo, Jeong-Hoi
Woo, Sam-Yong
Kim, Jaeuk U.
Kim, Young-Min
author_facet Yang, Tae-Heon
Jo, Gwanghyun
Koo, Jeong-Hoi
Woo, Sam-Yong
Kim, Jaeuk U.
Kim, Young-Min
author_sort Yang, Tae-Heon
collection PubMed
description BACKGROUND: There exists a growing need for a cost-effective, reliable, and portable pulsation simulator that can generate a wide variety of pulses depending on age and cardiovascular disease. For constructing compact pulsation simulator, this study proposes to use a pneumatic actuator based on cam-follower mechanism controlled by a DC motor. The simulator is intended to generate pulse waveforms for a range of pulse pressures and heart beats that are realistic to human blood pulsations. METHODS: This study first performed in vivo testing of a healthy young man to collect his pulse waveforms using a robotic tonometry system (RTS). Based on the collected data a representative human radial pulse waveform is obtained by conducting a mathematical analysis. This standard pulse waveform is then used to design the cam profile. Upon fabrication of the cam, the pulsatile simulator, consisting of the pulse pressure generating component, pressure and heart rate adjusting units, and the real-time pulse display, is constructed. Using the RTS, a series of testing was performed on the prototype to collect its pulse waveforms by varying the pressure levels and heart rates. Followed by the testing, the pulse waveforms generated by the prototype are compared with the representative, in vivo, pulse waveform. RESULTS: The radial Augmentation Index analysis results show that the percent error between the simulator data and human pulse profiles is sufficiently small, indicating that the first two peak pressures agree well. Moreover, the phase analysis results show that the phase delay errors between the pulse waveforms of the prototype and the representative waveform are adequately small, confirming that the prototype simulator is capable of simulating realistic human pulse waveforms. CONCLUSIONS: This study demonstrated that a very accurate radial pressure waveform can be reproduced using the cam-based simulator. It can be concluded that the same testing and design methods can be used to generate pulse waveforms for other age groups or any target pulse waveforms. Such a simulator can make a contribution to the research efforts, such as development of wearable pressure sensors, standardization of pulse diagnosis in oriental medicine, and training medical professionals for pulse diagnosis techniques.
format Online
Article
Text
id pubmed-6317228
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-63172282019-01-08 A compact pulsatile simulator based on cam-follower mechanism for generating radial pulse waveforms Yang, Tae-Heon Jo, Gwanghyun Koo, Jeong-Hoi Woo, Sam-Yong Kim, Jaeuk U. Kim, Young-Min Biomed Eng Online Research BACKGROUND: There exists a growing need for a cost-effective, reliable, and portable pulsation simulator that can generate a wide variety of pulses depending on age and cardiovascular disease. For constructing compact pulsation simulator, this study proposes to use a pneumatic actuator based on cam-follower mechanism controlled by a DC motor. The simulator is intended to generate pulse waveforms for a range of pulse pressures and heart beats that are realistic to human blood pulsations. METHODS: This study first performed in vivo testing of a healthy young man to collect his pulse waveforms using a robotic tonometry system (RTS). Based on the collected data a representative human radial pulse waveform is obtained by conducting a mathematical analysis. This standard pulse waveform is then used to design the cam profile. Upon fabrication of the cam, the pulsatile simulator, consisting of the pulse pressure generating component, pressure and heart rate adjusting units, and the real-time pulse display, is constructed. Using the RTS, a series of testing was performed on the prototype to collect its pulse waveforms by varying the pressure levels and heart rates. Followed by the testing, the pulse waveforms generated by the prototype are compared with the representative, in vivo, pulse waveform. RESULTS: The radial Augmentation Index analysis results show that the percent error between the simulator data and human pulse profiles is sufficiently small, indicating that the first two peak pressures agree well. Moreover, the phase analysis results show that the phase delay errors between the pulse waveforms of the prototype and the representative waveform are adequately small, confirming that the prototype simulator is capable of simulating realistic human pulse waveforms. CONCLUSIONS: This study demonstrated that a very accurate radial pressure waveform can be reproduced using the cam-based simulator. It can be concluded that the same testing and design methods can be used to generate pulse waveforms for other age groups or any target pulse waveforms. Such a simulator can make a contribution to the research efforts, such as development of wearable pressure sensors, standardization of pulse diagnosis in oriental medicine, and training medical professionals for pulse diagnosis techniques. BioMed Central 2019-01-03 /pmc/articles/PMC6317228/ /pubmed/30602383 http://dx.doi.org/10.1186/s12938-018-0620-3 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Yang, Tae-Heon
Jo, Gwanghyun
Koo, Jeong-Hoi
Woo, Sam-Yong
Kim, Jaeuk U.
Kim, Young-Min
A compact pulsatile simulator based on cam-follower mechanism for generating radial pulse waveforms
title A compact pulsatile simulator based on cam-follower mechanism for generating radial pulse waveforms
title_full A compact pulsatile simulator based on cam-follower mechanism for generating radial pulse waveforms
title_fullStr A compact pulsatile simulator based on cam-follower mechanism for generating radial pulse waveforms
title_full_unstemmed A compact pulsatile simulator based on cam-follower mechanism for generating radial pulse waveforms
title_short A compact pulsatile simulator based on cam-follower mechanism for generating radial pulse waveforms
title_sort compact pulsatile simulator based on cam-follower mechanism for generating radial pulse waveforms
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6317228/
https://www.ncbi.nlm.nih.gov/pubmed/30602383
http://dx.doi.org/10.1186/s12938-018-0620-3
work_keys_str_mv AT yangtaeheon acompactpulsatilesimulatorbasedoncamfollowermechanismforgeneratingradialpulsewaveforms
AT jogwanghyun acompactpulsatilesimulatorbasedoncamfollowermechanismforgeneratingradialpulsewaveforms
AT koojeonghoi acompactpulsatilesimulatorbasedoncamfollowermechanismforgeneratingradialpulsewaveforms
AT woosamyong acompactpulsatilesimulatorbasedoncamfollowermechanismforgeneratingradialpulsewaveforms
AT kimjaeuku acompactpulsatilesimulatorbasedoncamfollowermechanismforgeneratingradialpulsewaveforms
AT kimyoungmin acompactpulsatilesimulatorbasedoncamfollowermechanismforgeneratingradialpulsewaveforms
AT yangtaeheon compactpulsatilesimulatorbasedoncamfollowermechanismforgeneratingradialpulsewaveforms
AT jogwanghyun compactpulsatilesimulatorbasedoncamfollowermechanismforgeneratingradialpulsewaveforms
AT koojeonghoi compactpulsatilesimulatorbasedoncamfollowermechanismforgeneratingradialpulsewaveforms
AT woosamyong compactpulsatilesimulatorbasedoncamfollowermechanismforgeneratingradialpulsewaveforms
AT kimjaeuku compactpulsatilesimulatorbasedoncamfollowermechanismforgeneratingradialpulsewaveforms
AT kimyoungmin compactpulsatilesimulatorbasedoncamfollowermechanismforgeneratingradialpulsewaveforms