Cargando…

Micropulse Trabeculoplasty in Open Angle Glaucoma

BACKGROUND: We report the effect of micropulse laser trabeculoplasty (MLT) in the intraocular pressure (IOP) of patients with uncontrolled open-angle glaucoma (OAG). MATERIALS AND METHODS: In this retrospective review, 30 eyes with OAG were treated with a single session of MLT at the Vista Clinic in...

Descripción completa

Detalles Bibliográficos
Autores principales: Valera-Cornejo, Diego Alejandro, Loayza-Gamboa, Waldo, Herrera-Quiroz, Julio, Alvarado-Vlllacorta, Rosa, Cordova-Crisanto, Luis, Valderrama-Albino, Vanessa, Davalos, Nahuel P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6319042/
https://www.ncbi.nlm.nih.gov/pubmed/30662885
http://dx.doi.org/10.4103/abr.abr_203_17
_version_ 1783384999923286016
author Valera-Cornejo, Diego Alejandro
Loayza-Gamboa, Waldo
Herrera-Quiroz, Julio
Alvarado-Vlllacorta, Rosa
Cordova-Crisanto, Luis
Valderrama-Albino, Vanessa
Davalos, Nahuel P
author_facet Valera-Cornejo, Diego Alejandro
Loayza-Gamboa, Waldo
Herrera-Quiroz, Julio
Alvarado-Vlllacorta, Rosa
Cordova-Crisanto, Luis
Valderrama-Albino, Vanessa
Davalos, Nahuel P
author_sort Valera-Cornejo, Diego Alejandro
collection PubMed
description BACKGROUND: We report the effect of micropulse laser trabeculoplasty (MLT) in the intraocular pressure (IOP) of patients with uncontrolled open-angle glaucoma (OAG). MATERIALS AND METHODS: In this retrospective review, 30 eyes with OAG were treated with a single session of MLT at the Vista Clinic in Lima Perú. We used a 532 nm frequency doubled Nd: YAG laser to 360° of the trabecular meshwork with a power of 1000 mW, 15% of the duty cycle, and 300 ms of exposure. The IOP was measured at baseline and at 1 day, 1 week, 3 months, and 6 months post-treatment and were followed up for one last control. RESULTS: The mean baseline IOP was 15.6 mmHg and in the last control was 12.8 mmHg, mean follow-up time of 19 months (±10 standard deviation [SD]). The mean reduction of IOP in the 1(st) day was 1.6 mmHg (±2.6 SD) and 1.2 mmHg (±3.3 SD) in the last follow-up. The mean percentage of IOP reduction was 17.9% and 7 eyes (40%) had IOP reduction >20%. No statistical significant difference in relation to demographic characteristics of the patients. The greatest reduction was achieved in the 1(st) day with a median of 2.00 (P < 0.001). A tendency to achieve a higher reduction of IOP in patients with higher baseline IOP was found but was not statistically significant. No adverse reactions occurred. CONCLUSIONS: MLT slightly reduced the IOP in a few patients with uncontrolled OAG for a very short time and may not be suitable for these patients.
format Online
Article
Text
id pubmed-6319042
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-63190422019-01-18 Micropulse Trabeculoplasty in Open Angle Glaucoma Valera-Cornejo, Diego Alejandro Loayza-Gamboa, Waldo Herrera-Quiroz, Julio Alvarado-Vlllacorta, Rosa Cordova-Crisanto, Luis Valderrama-Albino, Vanessa Davalos, Nahuel P Adv Biomed Res Original Article BACKGROUND: We report the effect of micropulse laser trabeculoplasty (MLT) in the intraocular pressure (IOP) of patients with uncontrolled open-angle glaucoma (OAG). MATERIALS AND METHODS: In this retrospective review, 30 eyes with OAG were treated with a single session of MLT at the Vista Clinic in Lima Perú. We used a 532 nm frequency doubled Nd: YAG laser to 360° of the trabecular meshwork with a power of 1000 mW, 15% of the duty cycle, and 300 ms of exposure. The IOP was measured at baseline and at 1 day, 1 week, 3 months, and 6 months post-treatment and were followed up for one last control. RESULTS: The mean baseline IOP was 15.6 mmHg and in the last control was 12.8 mmHg, mean follow-up time of 19 months (±10 standard deviation [SD]). The mean reduction of IOP in the 1(st) day was 1.6 mmHg (±2.6 SD) and 1.2 mmHg (±3.3 SD) in the last follow-up. The mean percentage of IOP reduction was 17.9% and 7 eyes (40%) had IOP reduction >20%. No statistical significant difference in relation to demographic characteristics of the patients. The greatest reduction was achieved in the 1(st) day with a median of 2.00 (P < 0.001). A tendency to achieve a higher reduction of IOP in patients with higher baseline IOP was found but was not statistically significant. No adverse reactions occurred. CONCLUSIONS: MLT slightly reduced the IOP in a few patients with uncontrolled OAG for a very short time and may not be suitable for these patients. Medknow Publications & Media Pvt Ltd 2018-12-19 /pmc/articles/PMC6319042/ /pubmed/30662885 http://dx.doi.org/10.4103/abr.abr_203_17 Text en Copyright: © 2018 Advanced Biomedical Research http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Valera-Cornejo, Diego Alejandro
Loayza-Gamboa, Waldo
Herrera-Quiroz, Julio
Alvarado-Vlllacorta, Rosa
Cordova-Crisanto, Luis
Valderrama-Albino, Vanessa
Davalos, Nahuel P
Micropulse Trabeculoplasty in Open Angle Glaucoma
title Micropulse Trabeculoplasty in Open Angle Glaucoma
title_full Micropulse Trabeculoplasty in Open Angle Glaucoma
title_fullStr Micropulse Trabeculoplasty in Open Angle Glaucoma
title_full_unstemmed Micropulse Trabeculoplasty in Open Angle Glaucoma
title_short Micropulse Trabeculoplasty in Open Angle Glaucoma
title_sort micropulse trabeculoplasty in open angle glaucoma
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6319042/
https://www.ncbi.nlm.nih.gov/pubmed/30662885
http://dx.doi.org/10.4103/abr.abr_203_17
work_keys_str_mv AT valeracornejodiegoalejandro micropulsetrabeculoplastyinopenangleglaucoma
AT loayzagamboawaldo micropulsetrabeculoplastyinopenangleglaucoma
AT herreraquirozjulio micropulsetrabeculoplastyinopenangleglaucoma
AT alvaradovlllacortarosa micropulsetrabeculoplastyinopenangleglaucoma
AT cordovacrisantoluis micropulsetrabeculoplastyinopenangleglaucoma
AT valderramaalbinovanessa micropulsetrabeculoplastyinopenangleglaucoma
AT davalosnahuelp micropulsetrabeculoplastyinopenangleglaucoma