Cargando…

Balloon-assisted coil embolization (BACE) of a wide-necked renal artery aneurysm using the intracranial scepter C compliant occlusion balloon catheter

BACKGROUND: True renal artery aneurysms (TRAA) are an uncommon pathology, with a prevalence of less than 1%. Treatment of TRAAs is generally recommended when the aneurysm sac equals or exceeds 2cms. Both wide-necked and main renal artery branch aneurysms represent a challenge for conventional endova...

Descripción completa

Detalles Bibliográficos
Autores principales: Das, Jeeban Paul, Asadi, Hamed, Kok, Hong Kuan, Phelan, Emma, O’Hare, Alan, Lee, Michael J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6319664/
https://www.ncbi.nlm.nih.gov/pubmed/30652144
http://dx.doi.org/10.1186/s42155-018-0018-0
_version_ 1783385101539737600
author Das, Jeeban Paul
Asadi, Hamed
Kok, Hong Kuan
Phelan, Emma
O’Hare, Alan
Lee, Michael J.
author_facet Das, Jeeban Paul
Asadi, Hamed
Kok, Hong Kuan
Phelan, Emma
O’Hare, Alan
Lee, Michael J.
author_sort Das, Jeeban Paul
collection PubMed
description BACKGROUND: True renal artery aneurysms (TRAA) are an uncommon pathology, with a prevalence of less than 1%. Treatment of TRAAs is generally recommended when the aneurysm sac equals or exceeds 2cms. Both wide-necked and main renal artery branch aneurysms represent a challenge for conventional endovascular coil embolization due to the risk of coil migration. MAIN BODY: Intra-procedural remodeling of the aneurysm neck using Balloon Assisted Coil Embolization (BACE) is considered a suitable alternative in challenging cases of visceral artery aneurysms. SHORT CONCLUSION: We describe the novel use of the Scepter C (MicroVention Terumo, Tustin, CA) compliant double lumen neurovascular occlusion balloon in the treatment of a wide-necked branch TRAA in a patient with a solitary kidney.
format Online
Article
Text
id pubmed-6319664
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-63196642019-01-14 Balloon-assisted coil embolization (BACE) of a wide-necked renal artery aneurysm using the intracranial scepter C compliant occlusion balloon catheter Das, Jeeban Paul Asadi, Hamed Kok, Hong Kuan Phelan, Emma O’Hare, Alan Lee, Michael J. CVIR Endovasc New Technologies BACKGROUND: True renal artery aneurysms (TRAA) are an uncommon pathology, with a prevalence of less than 1%. Treatment of TRAAs is generally recommended when the aneurysm sac equals or exceeds 2cms. Both wide-necked and main renal artery branch aneurysms represent a challenge for conventional endovascular coil embolization due to the risk of coil migration. MAIN BODY: Intra-procedural remodeling of the aneurysm neck using Balloon Assisted Coil Embolization (BACE) is considered a suitable alternative in challenging cases of visceral artery aneurysms. SHORT CONCLUSION: We describe the novel use of the Scepter C (MicroVention Terumo, Tustin, CA) compliant double lumen neurovascular occlusion balloon in the treatment of a wide-necked branch TRAA in a patient with a solitary kidney. Springer International Publishing 2018-10-03 /pmc/articles/PMC6319664/ /pubmed/30652144 http://dx.doi.org/10.1186/s42155-018-0018-0 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle New Technologies
Das, Jeeban Paul
Asadi, Hamed
Kok, Hong Kuan
Phelan, Emma
O’Hare, Alan
Lee, Michael J.
Balloon-assisted coil embolization (BACE) of a wide-necked renal artery aneurysm using the intracranial scepter C compliant occlusion balloon catheter
title Balloon-assisted coil embolization (BACE) of a wide-necked renal artery aneurysm using the intracranial scepter C compliant occlusion balloon catheter
title_full Balloon-assisted coil embolization (BACE) of a wide-necked renal artery aneurysm using the intracranial scepter C compliant occlusion balloon catheter
title_fullStr Balloon-assisted coil embolization (BACE) of a wide-necked renal artery aneurysm using the intracranial scepter C compliant occlusion balloon catheter
title_full_unstemmed Balloon-assisted coil embolization (BACE) of a wide-necked renal artery aneurysm using the intracranial scepter C compliant occlusion balloon catheter
title_short Balloon-assisted coil embolization (BACE) of a wide-necked renal artery aneurysm using the intracranial scepter C compliant occlusion balloon catheter
title_sort balloon-assisted coil embolization (bace) of a wide-necked renal artery aneurysm using the intracranial scepter c compliant occlusion balloon catheter
topic New Technologies
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6319664/
https://www.ncbi.nlm.nih.gov/pubmed/30652144
http://dx.doi.org/10.1186/s42155-018-0018-0
work_keys_str_mv AT dasjeebanpaul balloonassistedcoilembolizationbaceofawideneckedrenalarteryaneurysmusingtheintracranialscepterccompliantocclusionballooncatheter
AT asadihamed balloonassistedcoilembolizationbaceofawideneckedrenalarteryaneurysmusingtheintracranialscepterccompliantocclusionballooncatheter
AT kokhongkuan balloonassistedcoilembolizationbaceofawideneckedrenalarteryaneurysmusingtheintracranialscepterccompliantocclusionballooncatheter
AT phelanemma balloonassistedcoilembolizationbaceofawideneckedrenalarteryaneurysmusingtheintracranialscepterccompliantocclusionballooncatheter
AT oharealan balloonassistedcoilembolizationbaceofawideneckedrenalarteryaneurysmusingtheintracranialscepterccompliantocclusionballooncatheter
AT leemichaelj balloonassistedcoilembolizationbaceofawideneckedrenalarteryaneurysmusingtheintracranialscepterccompliantocclusionballooncatheter