Comparative mouse lung injury by nickel nanoparticles with differential surface modification
BACKGROUND: Previous studies have demonstrated that exposure to nickel nanoparticles (Nano-Ni) causes oxidative stress and severe, persistent lung inflammation, which are strongly associated with pulmonary toxicity. However, few studies have investigated whether surface modification of Nano-Ni could...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6322282/ https://www.ncbi.nlm.nih.gov/pubmed/30616599 http://dx.doi.org/10.1186/s12951-018-0436-0 |
_version_ | 1783385589703245824 |
---|---|
author | Mo, Yiqun Jiang, Mizu Zhang, Yue Wan, Rong Li, Jing Zhong, Chuan-Jian Li, Huangyuan Tang, Shichuan Zhang, Qunwei |
author_facet | Mo, Yiqun Jiang, Mizu Zhang, Yue Wan, Rong Li, Jing Zhong, Chuan-Jian Li, Huangyuan Tang, Shichuan Zhang, Qunwei |
author_sort | Mo, Yiqun |
collection | PubMed |
description | BACKGROUND: Previous studies have demonstrated that exposure to nickel nanoparticles (Nano-Ni) causes oxidative stress and severe, persistent lung inflammation, which are strongly associated with pulmonary toxicity. However, few studies have investigated whether surface modification of Nano-Ni could alter Nano-Ni-induced lung injury, inflammation, and fibrosis in vivo. Here, we propose that alteration of physicochemical properties of Nano-Ni through modification of Nano-Ni surface may change Nano-Ni-induced lung injury, inflammation, and fibrosis. METHODS: At first, dose–response and time-response studies were performed to observe lung inflammation and injury caused by Nano-Ni. In the dose–response studies, mice were intratracheally instilled with 0, 10, 20, 50, and 100 μg per mouse of Nano-Ni and sacrificed at day 3 post-exposure. In the time-response studies, mice were intratracheally instilled with 50 µg per mouse of Nano-Ni and sacrificed at days 1, 3, 7, 14, 28, and 42 post-instillation. At the end of the experiment, mice were bronchoalveolar lavaged (BAL) and the neutrophil count, CXCL1/KC level, LDH activity, and concentration of total protein in the BAL fluid (BALF) were determined. In the comparative studies, mice were intratracheally instilled with 50 μg per mouse of Nano-Ni or with the same molar concentration of Ni as Nano-Ni of either partially [O]-passivated Nano-Ni (Nano-Ni–P) or carbon-coated Nano-Ni (Nano-Ni–C). At day 3 post-exposure, BAL was performed and the above cellular and biochemical parameters in the BALF were analyzed. The MMP-2/9 protein levels and activities in the BALF and mouse lung tissues were also determined. Mouse lung tissues were also collected for H&E staining, and measurement of thiobarbituric acid reactive substances (TBARS) and 8-hydroxy-2′-deoxyguanosine (8-OHdG) in the genomic DNA. At day 42 post-exposure, mouse right lung tissues were collected for H&E and Trichrome stainings, and left lung tissues were collected to determine the hydroxyproline content. RESULTS: Exposure of mice to Nano-Ni resulted in a dose–response increase in acute lung inflammation and injury reflected by increased neutrophil count, CXCL1/KC level, LDH activity, and concentration of total protein in the BALF. The time-response study showed that Nano-Ni-induced acute lung inflammation and injury appeared as early as day 1, peaked at day 3, and attenuated at day 7 post-instillation. Although the neutrophil count, CXCL1/KC level, LDH activity, and concentration of total protein in the BALF dramatically decreased over the time, their levels were still higher than those of the controls even at day 42 post-exposure. Based on the results of the dose- and time-response studies, we chose a dose of 50 µg per mouse of Nano-Ni, and day 3 post-exposure as short-term and day 42 post-exposure as long-term to compare the effects of Nano-Ni, Nano-Ni–P, and Nano-Ni–C on mouse lungs. At day 3 post-exposure, 50 μg per mouse of Nano-Ni caused acute lung inflammation and injury that were reflected by increased neutrophil count, CXCL1/KC level, LDH activity, concentration of total protein, and MMP-2/9 protein levels and activities in the BALF. Nano-Ni exposure also caused increased MMP-2/9 activities in the mouse lung tissues. Histologically, infiltration of large numbers of neutrophils and macrophages in the alveolar space and interstitial tissues was observed in mouse lungs exposed to Nano-Ni. Nano-Ni–P exposure caused similar acute lung inflammation and injury as Nano-Ni. However, exposure to Nano-Ni–C only caused mild acute lung inflammation and injury. At day 42 post-exposure, Nano-Ni caused extensive interstitial fibrosis and proliferation of interstitial cells with inflammatory cells infiltrating the alveolar septa and alveolar space. Lung fibrosis was also observed in Nano-Ni–P-exposed lungs, but to a much lesser degree. Only slight or no lung fibrosis was observed in Nano-Ni–C-exposed lungs. Nano-Ni and Nano-Ni–P, but not Nano-Ni–C, caused significantly elevated levels of TBARS in mouse lung tissues and 8-OHdG in mouse lung tissue genomic DNA, suggesting that Nano-Ni and Nano-Ni–P induce lipid peroxidation and oxidative DNA damage in mouse lung tissues, while Nano-Ni–C does not. CONCLUSION: Our results demonstrate that short-term Nano-Ni exposure causes acute lung inflammation and injury, while long-term Nano-Ni exposure causes chronic lung inflammation and fibrosis. Surface modification of Nano-Ni alleviates Nano-Ni-induced pulmonary effects; partially passivated Nano-Ni causes similar effects as Nano-Ni, but the chronic inflammation and fibrosis were at a much lesser degree. Carbon coating significantly alleviates Nano-Ni-induced acute and chronic lung inflammation and injury. |
format | Online Article Text |
id | pubmed-6322282 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-63222822019-01-09 Comparative mouse lung injury by nickel nanoparticles with differential surface modification Mo, Yiqun Jiang, Mizu Zhang, Yue Wan, Rong Li, Jing Zhong, Chuan-Jian Li, Huangyuan Tang, Shichuan Zhang, Qunwei J Nanobiotechnology Research BACKGROUND: Previous studies have demonstrated that exposure to nickel nanoparticles (Nano-Ni) causes oxidative stress and severe, persistent lung inflammation, which are strongly associated with pulmonary toxicity. However, few studies have investigated whether surface modification of Nano-Ni could alter Nano-Ni-induced lung injury, inflammation, and fibrosis in vivo. Here, we propose that alteration of physicochemical properties of Nano-Ni through modification of Nano-Ni surface may change Nano-Ni-induced lung injury, inflammation, and fibrosis. METHODS: At first, dose–response and time-response studies were performed to observe lung inflammation and injury caused by Nano-Ni. In the dose–response studies, mice were intratracheally instilled with 0, 10, 20, 50, and 100 μg per mouse of Nano-Ni and sacrificed at day 3 post-exposure. In the time-response studies, mice were intratracheally instilled with 50 µg per mouse of Nano-Ni and sacrificed at days 1, 3, 7, 14, 28, and 42 post-instillation. At the end of the experiment, mice were bronchoalveolar lavaged (BAL) and the neutrophil count, CXCL1/KC level, LDH activity, and concentration of total protein in the BAL fluid (BALF) were determined. In the comparative studies, mice were intratracheally instilled with 50 μg per mouse of Nano-Ni or with the same molar concentration of Ni as Nano-Ni of either partially [O]-passivated Nano-Ni (Nano-Ni–P) or carbon-coated Nano-Ni (Nano-Ni–C). At day 3 post-exposure, BAL was performed and the above cellular and biochemical parameters in the BALF were analyzed. The MMP-2/9 protein levels and activities in the BALF and mouse lung tissues were also determined. Mouse lung tissues were also collected for H&E staining, and measurement of thiobarbituric acid reactive substances (TBARS) and 8-hydroxy-2′-deoxyguanosine (8-OHdG) in the genomic DNA. At day 42 post-exposure, mouse right lung tissues were collected for H&E and Trichrome stainings, and left lung tissues were collected to determine the hydroxyproline content. RESULTS: Exposure of mice to Nano-Ni resulted in a dose–response increase in acute lung inflammation and injury reflected by increased neutrophil count, CXCL1/KC level, LDH activity, and concentration of total protein in the BALF. The time-response study showed that Nano-Ni-induced acute lung inflammation and injury appeared as early as day 1, peaked at day 3, and attenuated at day 7 post-instillation. Although the neutrophil count, CXCL1/KC level, LDH activity, and concentration of total protein in the BALF dramatically decreased over the time, their levels were still higher than those of the controls even at day 42 post-exposure. Based on the results of the dose- and time-response studies, we chose a dose of 50 µg per mouse of Nano-Ni, and day 3 post-exposure as short-term and day 42 post-exposure as long-term to compare the effects of Nano-Ni, Nano-Ni–P, and Nano-Ni–C on mouse lungs. At day 3 post-exposure, 50 μg per mouse of Nano-Ni caused acute lung inflammation and injury that were reflected by increased neutrophil count, CXCL1/KC level, LDH activity, concentration of total protein, and MMP-2/9 protein levels and activities in the BALF. Nano-Ni exposure also caused increased MMP-2/9 activities in the mouse lung tissues. Histologically, infiltration of large numbers of neutrophils and macrophages in the alveolar space and interstitial tissues was observed in mouse lungs exposed to Nano-Ni. Nano-Ni–P exposure caused similar acute lung inflammation and injury as Nano-Ni. However, exposure to Nano-Ni–C only caused mild acute lung inflammation and injury. At day 42 post-exposure, Nano-Ni caused extensive interstitial fibrosis and proliferation of interstitial cells with inflammatory cells infiltrating the alveolar septa and alveolar space. Lung fibrosis was also observed in Nano-Ni–P-exposed lungs, but to a much lesser degree. Only slight or no lung fibrosis was observed in Nano-Ni–C-exposed lungs. Nano-Ni and Nano-Ni–P, but not Nano-Ni–C, caused significantly elevated levels of TBARS in mouse lung tissues and 8-OHdG in mouse lung tissue genomic DNA, suggesting that Nano-Ni and Nano-Ni–P induce lipid peroxidation and oxidative DNA damage in mouse lung tissues, while Nano-Ni–C does not. CONCLUSION: Our results demonstrate that short-term Nano-Ni exposure causes acute lung inflammation and injury, while long-term Nano-Ni exposure causes chronic lung inflammation and fibrosis. Surface modification of Nano-Ni alleviates Nano-Ni-induced pulmonary effects; partially passivated Nano-Ni causes similar effects as Nano-Ni, but the chronic inflammation and fibrosis were at a much lesser degree. Carbon coating significantly alleviates Nano-Ni-induced acute and chronic lung inflammation and injury. BioMed Central 2019-01-07 /pmc/articles/PMC6322282/ /pubmed/30616599 http://dx.doi.org/10.1186/s12951-018-0436-0 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Mo, Yiqun Jiang, Mizu Zhang, Yue Wan, Rong Li, Jing Zhong, Chuan-Jian Li, Huangyuan Tang, Shichuan Zhang, Qunwei Comparative mouse lung injury by nickel nanoparticles with differential surface modification |
title | Comparative mouse lung injury by nickel nanoparticles with differential surface modification |
title_full | Comparative mouse lung injury by nickel nanoparticles with differential surface modification |
title_fullStr | Comparative mouse lung injury by nickel nanoparticles with differential surface modification |
title_full_unstemmed | Comparative mouse lung injury by nickel nanoparticles with differential surface modification |
title_short | Comparative mouse lung injury by nickel nanoparticles with differential surface modification |
title_sort | comparative mouse lung injury by nickel nanoparticles with differential surface modification |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6322282/ https://www.ncbi.nlm.nih.gov/pubmed/30616599 http://dx.doi.org/10.1186/s12951-018-0436-0 |
work_keys_str_mv | AT moyiqun comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification AT jiangmizu comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification AT zhangyue comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification AT wanrong comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification AT lijing comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification AT zhongchuanjian comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification AT lihuangyuan comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification AT tangshichuan comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification AT zhangqunwei comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification |