Cargando…

Comparative mouse lung injury by nickel nanoparticles with differential surface modification

BACKGROUND: Previous studies have demonstrated that exposure to nickel nanoparticles (Nano-Ni) causes oxidative stress and severe, persistent lung inflammation, which are strongly associated with pulmonary toxicity. However, few studies have investigated whether surface modification of Nano-Ni could...

Descripción completa

Detalles Bibliográficos
Autores principales: Mo, Yiqun, Jiang, Mizu, Zhang, Yue, Wan, Rong, Li, Jing, Zhong, Chuan-Jian, Li, Huangyuan, Tang, Shichuan, Zhang, Qunwei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6322282/
https://www.ncbi.nlm.nih.gov/pubmed/30616599
http://dx.doi.org/10.1186/s12951-018-0436-0
_version_ 1783385589703245824
author Mo, Yiqun
Jiang, Mizu
Zhang, Yue
Wan, Rong
Li, Jing
Zhong, Chuan-Jian
Li, Huangyuan
Tang, Shichuan
Zhang, Qunwei
author_facet Mo, Yiqun
Jiang, Mizu
Zhang, Yue
Wan, Rong
Li, Jing
Zhong, Chuan-Jian
Li, Huangyuan
Tang, Shichuan
Zhang, Qunwei
author_sort Mo, Yiqun
collection PubMed
description BACKGROUND: Previous studies have demonstrated that exposure to nickel nanoparticles (Nano-Ni) causes oxidative stress and severe, persistent lung inflammation, which are strongly associated with pulmonary toxicity. However, few studies have investigated whether surface modification of Nano-Ni could alter Nano-Ni-induced lung injury, inflammation, and fibrosis in vivo. Here, we propose that alteration of physicochemical properties of Nano-Ni through modification of Nano-Ni surface may change Nano-Ni-induced lung injury, inflammation, and fibrosis. METHODS: At first, dose–response and time-response studies were performed to observe lung inflammation and injury caused by Nano-Ni. In the dose–response studies, mice were intratracheally instilled with 0, 10, 20, 50, and 100 μg per mouse of Nano-Ni and sacrificed at day 3 post-exposure. In the time-response studies, mice were intratracheally instilled with 50 µg per mouse of Nano-Ni and sacrificed at days 1, 3, 7, 14, 28, and 42 post-instillation. At the end of the experiment, mice were bronchoalveolar lavaged (BAL) and the neutrophil count, CXCL1/KC level, LDH activity, and concentration of total protein in the BAL fluid (BALF) were determined. In the comparative studies, mice were intratracheally instilled with 50 μg per mouse of Nano-Ni or with the same molar concentration of Ni as Nano-Ni of either partially [O]-passivated Nano-Ni (Nano-Ni–P) or carbon-coated Nano-Ni (Nano-Ni–C). At day 3 post-exposure, BAL was performed and the above cellular and biochemical parameters in the BALF were analyzed. The MMP-2/9 protein levels and activities in the BALF and mouse lung tissues were also determined. Mouse lung tissues were also collected for H&E staining, and measurement of thiobarbituric acid reactive substances (TBARS) and 8-hydroxy-2′-deoxyguanosine (8-OHdG) in the genomic DNA. At day 42 post-exposure, mouse right lung tissues were collected for H&E and Trichrome stainings, and left lung tissues were collected to determine the hydroxyproline content. RESULTS: Exposure of mice to Nano-Ni resulted in a dose–response increase in acute lung inflammation and injury reflected by increased neutrophil count, CXCL1/KC level, LDH activity, and concentration of total protein in the BALF. The time-response study showed that Nano-Ni-induced acute lung inflammation and injury appeared as early as day 1, peaked at day 3, and attenuated at day 7 post-instillation. Although the neutrophil count, CXCL1/KC level, LDH activity, and concentration of total protein in the BALF dramatically decreased over the time, their levels were still higher than those of the controls even at day 42 post-exposure. Based on the results of the dose- and time-response studies, we chose a dose of 50 µg per mouse of Nano-Ni, and day 3 post-exposure as short-term and day 42 post-exposure as long-term to compare the effects of Nano-Ni, Nano-Ni–P, and Nano-Ni–C on mouse lungs. At day 3 post-exposure, 50 μg per mouse of Nano-Ni caused acute lung inflammation and injury that were reflected by increased neutrophil count, CXCL1/KC level, LDH activity, concentration of total protein, and MMP-2/9 protein levels and activities in the BALF. Nano-Ni exposure also caused increased MMP-2/9 activities in the mouse lung tissues. Histologically, infiltration of large numbers of neutrophils and macrophages in the alveolar space and interstitial tissues was observed in mouse lungs exposed to Nano-Ni. Nano-Ni–P exposure caused similar acute lung inflammation and injury as Nano-Ni. However, exposure to Nano-Ni–C only caused mild acute lung inflammation and injury. At day 42 post-exposure, Nano-Ni caused extensive interstitial fibrosis and proliferation of interstitial cells with inflammatory cells infiltrating the alveolar septa and alveolar space. Lung fibrosis was also observed in Nano-Ni–P-exposed lungs, but to a much lesser degree. Only slight or no lung fibrosis was observed in Nano-Ni–C-exposed lungs. Nano-Ni and Nano-Ni–P, but not Nano-Ni–C, caused significantly elevated levels of TBARS in mouse lung tissues and 8-OHdG in mouse lung tissue genomic DNA, suggesting that Nano-Ni and Nano-Ni–P induce lipid peroxidation and oxidative DNA damage in mouse lung tissues, while Nano-Ni–C does not. CONCLUSION: Our results demonstrate that short-term Nano-Ni exposure causes acute lung inflammation and injury, while long-term Nano-Ni exposure causes chronic lung inflammation and fibrosis. Surface modification of Nano-Ni alleviates Nano-Ni-induced pulmonary effects; partially passivated Nano-Ni causes similar effects as Nano-Ni, but the chronic inflammation and fibrosis were at a much lesser degree. Carbon coating significantly alleviates Nano-Ni-induced acute and chronic lung inflammation and injury.
format Online
Article
Text
id pubmed-6322282
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-63222822019-01-09 Comparative mouse lung injury by nickel nanoparticles with differential surface modification Mo, Yiqun Jiang, Mizu Zhang, Yue Wan, Rong Li, Jing Zhong, Chuan-Jian Li, Huangyuan Tang, Shichuan Zhang, Qunwei J Nanobiotechnology Research BACKGROUND: Previous studies have demonstrated that exposure to nickel nanoparticles (Nano-Ni) causes oxidative stress and severe, persistent lung inflammation, which are strongly associated with pulmonary toxicity. However, few studies have investigated whether surface modification of Nano-Ni could alter Nano-Ni-induced lung injury, inflammation, and fibrosis in vivo. Here, we propose that alteration of physicochemical properties of Nano-Ni through modification of Nano-Ni surface may change Nano-Ni-induced lung injury, inflammation, and fibrosis. METHODS: At first, dose–response and time-response studies were performed to observe lung inflammation and injury caused by Nano-Ni. In the dose–response studies, mice were intratracheally instilled with 0, 10, 20, 50, and 100 μg per mouse of Nano-Ni and sacrificed at day 3 post-exposure. In the time-response studies, mice were intratracheally instilled with 50 µg per mouse of Nano-Ni and sacrificed at days 1, 3, 7, 14, 28, and 42 post-instillation. At the end of the experiment, mice were bronchoalveolar lavaged (BAL) and the neutrophil count, CXCL1/KC level, LDH activity, and concentration of total protein in the BAL fluid (BALF) were determined. In the comparative studies, mice were intratracheally instilled with 50 μg per mouse of Nano-Ni or with the same molar concentration of Ni as Nano-Ni of either partially [O]-passivated Nano-Ni (Nano-Ni–P) or carbon-coated Nano-Ni (Nano-Ni–C). At day 3 post-exposure, BAL was performed and the above cellular and biochemical parameters in the BALF were analyzed. The MMP-2/9 protein levels and activities in the BALF and mouse lung tissues were also determined. Mouse lung tissues were also collected for H&E staining, and measurement of thiobarbituric acid reactive substances (TBARS) and 8-hydroxy-2′-deoxyguanosine (8-OHdG) in the genomic DNA. At day 42 post-exposure, mouse right lung tissues were collected for H&E and Trichrome stainings, and left lung tissues were collected to determine the hydroxyproline content. RESULTS: Exposure of mice to Nano-Ni resulted in a dose–response increase in acute lung inflammation and injury reflected by increased neutrophil count, CXCL1/KC level, LDH activity, and concentration of total protein in the BALF. The time-response study showed that Nano-Ni-induced acute lung inflammation and injury appeared as early as day 1, peaked at day 3, and attenuated at day 7 post-instillation. Although the neutrophil count, CXCL1/KC level, LDH activity, and concentration of total protein in the BALF dramatically decreased over the time, their levels were still higher than those of the controls even at day 42 post-exposure. Based on the results of the dose- and time-response studies, we chose a dose of 50 µg per mouse of Nano-Ni, and day 3 post-exposure as short-term and day 42 post-exposure as long-term to compare the effects of Nano-Ni, Nano-Ni–P, and Nano-Ni–C on mouse lungs. At day 3 post-exposure, 50 μg per mouse of Nano-Ni caused acute lung inflammation and injury that were reflected by increased neutrophil count, CXCL1/KC level, LDH activity, concentration of total protein, and MMP-2/9 protein levels and activities in the BALF. Nano-Ni exposure also caused increased MMP-2/9 activities in the mouse lung tissues. Histologically, infiltration of large numbers of neutrophils and macrophages in the alveolar space and interstitial tissues was observed in mouse lungs exposed to Nano-Ni. Nano-Ni–P exposure caused similar acute lung inflammation and injury as Nano-Ni. However, exposure to Nano-Ni–C only caused mild acute lung inflammation and injury. At day 42 post-exposure, Nano-Ni caused extensive interstitial fibrosis and proliferation of interstitial cells with inflammatory cells infiltrating the alveolar septa and alveolar space. Lung fibrosis was also observed in Nano-Ni–P-exposed lungs, but to a much lesser degree. Only slight or no lung fibrosis was observed in Nano-Ni–C-exposed lungs. Nano-Ni and Nano-Ni–P, but not Nano-Ni–C, caused significantly elevated levels of TBARS in mouse lung tissues and 8-OHdG in mouse lung tissue genomic DNA, suggesting that Nano-Ni and Nano-Ni–P induce lipid peroxidation and oxidative DNA damage in mouse lung tissues, while Nano-Ni–C does not. CONCLUSION: Our results demonstrate that short-term Nano-Ni exposure causes acute lung inflammation and injury, while long-term Nano-Ni exposure causes chronic lung inflammation and fibrosis. Surface modification of Nano-Ni alleviates Nano-Ni-induced pulmonary effects; partially passivated Nano-Ni causes similar effects as Nano-Ni, but the chronic inflammation and fibrosis were at a much lesser degree. Carbon coating significantly alleviates Nano-Ni-induced acute and chronic lung inflammation and injury. BioMed Central 2019-01-07 /pmc/articles/PMC6322282/ /pubmed/30616599 http://dx.doi.org/10.1186/s12951-018-0436-0 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Mo, Yiqun
Jiang, Mizu
Zhang, Yue
Wan, Rong
Li, Jing
Zhong, Chuan-Jian
Li, Huangyuan
Tang, Shichuan
Zhang, Qunwei
Comparative mouse lung injury by nickel nanoparticles with differential surface modification
title Comparative mouse lung injury by nickel nanoparticles with differential surface modification
title_full Comparative mouse lung injury by nickel nanoparticles with differential surface modification
title_fullStr Comparative mouse lung injury by nickel nanoparticles with differential surface modification
title_full_unstemmed Comparative mouse lung injury by nickel nanoparticles with differential surface modification
title_short Comparative mouse lung injury by nickel nanoparticles with differential surface modification
title_sort comparative mouse lung injury by nickel nanoparticles with differential surface modification
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6322282/
https://www.ncbi.nlm.nih.gov/pubmed/30616599
http://dx.doi.org/10.1186/s12951-018-0436-0
work_keys_str_mv AT moyiqun comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification
AT jiangmizu comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification
AT zhangyue comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification
AT wanrong comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification
AT lijing comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification
AT zhongchuanjian comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification
AT lihuangyuan comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification
AT tangshichuan comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification
AT zhangqunwei comparativemouselunginjurybynickelnanoparticleswithdifferentialsurfacemodification