Cargando…

Development and validation of a new HPLC analytical method for the determination of diclofenac in tablets

A new selective and sensitive high-performance liquid chromatography (HPLC) method was developed for the quantification of diclofenac sodium (DS) in pharmaceutical dosage form using lidocaine as internal standard (IS). Chromatographic separation was achieved on a symmetry C18 column (4.6 mm × 150 mm...

Descripción completa

Detalles Bibliográficos
Autor principal: Alquadeib, Bushra Tuwfeeq
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6323142/
https://www.ncbi.nlm.nih.gov/pubmed/30662308
http://dx.doi.org/10.1016/j.jsps.2018.07.020
_version_ 1783385700934090752
author Alquadeib, Bushra Tuwfeeq
author_facet Alquadeib, Bushra Tuwfeeq
author_sort Alquadeib, Bushra Tuwfeeq
collection PubMed
description A new selective and sensitive high-performance liquid chromatography (HPLC) method was developed for the quantification of diclofenac sodium (DS) in pharmaceutical dosage form using lidocaine as internal standard (IS). Chromatographic separation was achieved on a symmetry C18 column (4.6 mm × 150 mm, 3 μm spherical particles) using 0.05 M orthophosporic (pH 2.0) 35% and acetonitrile as 65%, as the mobile phase at a flow rate of 2.0 mL/min and monitored at 210 nm. The run time was 2 min. The method was validated to fulfill International Conference on Harmonisation (ICH) requirements and this validation included specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision and robustness. The calibration curve was linear over the concentration range from 10 to 200 µg/ml, and lower limit of detection of 12.5 ng/ml. The accuracy and precision of the method were within the acceptable limit of ±20% at the lower limit of quantitation and ±15% at other concentrations. Diclofenac was unstable at room temperature it showed more than 25% loss after 24 h. While, DS is very stable at refrigerator 4 °C auto-sampler, freeze/thaw cycles and 30 days storage in a freezer at −35 ± 2 °C. All results were acceptable and this confirmed that the method is suitable for its intended use in routine quality control and assay of drugs.
format Online
Article
Text
id pubmed-6323142
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-63231422019-01-18 Development and validation of a new HPLC analytical method for the determination of diclofenac in tablets Alquadeib, Bushra Tuwfeeq Saudi Pharm J Article A new selective and sensitive high-performance liquid chromatography (HPLC) method was developed for the quantification of diclofenac sodium (DS) in pharmaceutical dosage form using lidocaine as internal standard (IS). Chromatographic separation was achieved on a symmetry C18 column (4.6 mm × 150 mm, 3 μm spherical particles) using 0.05 M orthophosporic (pH 2.0) 35% and acetonitrile as 65%, as the mobile phase at a flow rate of 2.0 mL/min and monitored at 210 nm. The run time was 2 min. The method was validated to fulfill International Conference on Harmonisation (ICH) requirements and this validation included specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision and robustness. The calibration curve was linear over the concentration range from 10 to 200 µg/ml, and lower limit of detection of 12.5 ng/ml. The accuracy and precision of the method were within the acceptable limit of ±20% at the lower limit of quantitation and ±15% at other concentrations. Diclofenac was unstable at room temperature it showed more than 25% loss after 24 h. While, DS is very stable at refrigerator 4 °C auto-sampler, freeze/thaw cycles and 30 days storage in a freezer at −35 ± 2 °C. All results were acceptable and this confirmed that the method is suitable for its intended use in routine quality control and assay of drugs. Elsevier 2019-01 2018-08-03 /pmc/articles/PMC6323142/ /pubmed/30662308 http://dx.doi.org/10.1016/j.jsps.2018.07.020 Text en © 2018 The Author http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Alquadeib, Bushra Tuwfeeq
Development and validation of a new HPLC analytical method for the determination of diclofenac in tablets
title Development and validation of a new HPLC analytical method for the determination of diclofenac in tablets
title_full Development and validation of a new HPLC analytical method for the determination of diclofenac in tablets
title_fullStr Development and validation of a new HPLC analytical method for the determination of diclofenac in tablets
title_full_unstemmed Development and validation of a new HPLC analytical method for the determination of diclofenac in tablets
title_short Development and validation of a new HPLC analytical method for the determination of diclofenac in tablets
title_sort development and validation of a new hplc analytical method for the determination of diclofenac in tablets
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6323142/
https://www.ncbi.nlm.nih.gov/pubmed/30662308
http://dx.doi.org/10.1016/j.jsps.2018.07.020
work_keys_str_mv AT alquadeibbushratuwfeeq developmentandvalidationofanewhplcanalyticalmethodforthedeterminationofdiclofenacintablets