Cargando…
Endoscopic Ultrasound-Guided Gallbladder Drainage for Aberrant Right Posterior Duct Obstruction Developing after Placement of a Covered Self-Expandable Metallic Stent in a Patient with Distal Biliary Obstruction
Endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) has been utilized as an alternative endoscopic technique for patients with acute cholecystitis. In addition to EUS-guided hepaticogastrostomy and EUS-guided cystogastrostomy, EUS-GBD has been reported as being useful for biliary drainage in...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
S. Karger AG
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6323387/ https://www.ncbi.nlm.nih.gov/pubmed/30631259 http://dx.doi.org/10.1159/000492215 |
_version_ | 1783385753265373184 |
---|---|
author | Suzuki, Yuko Hashimoto, Yusuke Shibuki, Taro Kan, Motoyasu Kimura, Gen Umemoto, Kumiko Watanabe, Kazuo Sasaki, Mitsuhito Takahashi, Hideaki Imaoka, Hiroshi Ohno, Izumi Mitsunaga, Shuichi Ikeda, Masafumi |
author_facet | Suzuki, Yuko Hashimoto, Yusuke Shibuki, Taro Kan, Motoyasu Kimura, Gen Umemoto, Kumiko Watanabe, Kazuo Sasaki, Mitsuhito Takahashi, Hideaki Imaoka, Hiroshi Ohno, Izumi Mitsunaga, Shuichi Ikeda, Masafumi |
author_sort | Suzuki, Yuko |
collection | PubMed |
description | Endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) has been utilized as an alternative endoscopic technique for patients with acute cholecystitis. In addition to EUS-guided hepaticogastrostomy and EUS-guided cystogastrostomy, EUS-GBD has been reported as being useful for biliary drainage in cases with distal malignant biliary obstruction instead of conventional endoscopic retrograde cholangiopancreatography. We present a case of successful EUS-GBD for malignant obstruction of an aberrant hepatic duct draining directly into the cystic duct. |
format | Online Article Text |
id | pubmed-6323387 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | S. Karger AG |
record_format | MEDLINE/PubMed |
spelling | pubmed-63233872019-01-10 Endoscopic Ultrasound-Guided Gallbladder Drainage for Aberrant Right Posterior Duct Obstruction Developing after Placement of a Covered Self-Expandable Metallic Stent in a Patient with Distal Biliary Obstruction Suzuki, Yuko Hashimoto, Yusuke Shibuki, Taro Kan, Motoyasu Kimura, Gen Umemoto, Kumiko Watanabe, Kazuo Sasaki, Mitsuhito Takahashi, Hideaki Imaoka, Hiroshi Ohno, Izumi Mitsunaga, Shuichi Ikeda, Masafumi Case Rep Gastroenterol Single Case Endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) has been utilized as an alternative endoscopic technique for patients with acute cholecystitis. In addition to EUS-guided hepaticogastrostomy and EUS-guided cystogastrostomy, EUS-GBD has been reported as being useful for biliary drainage in cases with distal malignant biliary obstruction instead of conventional endoscopic retrograde cholangiopancreatography. We present a case of successful EUS-GBD for malignant obstruction of an aberrant hepatic duct draining directly into the cystic duct. S. Karger AG 2018-11-28 /pmc/articles/PMC6323387/ /pubmed/30631259 http://dx.doi.org/10.1159/000492215 Text en Copyright © 2018 by S. Karger AG, Basel http://creativecommons.org/licenses/by-nc/4.0/ This article is licensed under the Creative Commons Attribution-NonCommercial-4.0 International License (CC BY-NC) (http://www.karger.com/Services/OpenAccessLicense). Usage and distribution for commercial purposes requires written permission. |
spellingShingle | Single Case Suzuki, Yuko Hashimoto, Yusuke Shibuki, Taro Kan, Motoyasu Kimura, Gen Umemoto, Kumiko Watanabe, Kazuo Sasaki, Mitsuhito Takahashi, Hideaki Imaoka, Hiroshi Ohno, Izumi Mitsunaga, Shuichi Ikeda, Masafumi Endoscopic Ultrasound-Guided Gallbladder Drainage for Aberrant Right Posterior Duct Obstruction Developing after Placement of a Covered Self-Expandable Metallic Stent in a Patient with Distal Biliary Obstruction |
title | Endoscopic Ultrasound-Guided Gallbladder Drainage for Aberrant Right Posterior Duct Obstruction Developing after Placement of a Covered Self-Expandable Metallic Stent in a Patient with Distal Biliary Obstruction |
title_full | Endoscopic Ultrasound-Guided Gallbladder Drainage for Aberrant Right Posterior Duct Obstruction Developing after Placement of a Covered Self-Expandable Metallic Stent in a Patient with Distal Biliary Obstruction |
title_fullStr | Endoscopic Ultrasound-Guided Gallbladder Drainage for Aberrant Right Posterior Duct Obstruction Developing after Placement of a Covered Self-Expandable Metallic Stent in a Patient with Distal Biliary Obstruction |
title_full_unstemmed | Endoscopic Ultrasound-Guided Gallbladder Drainage for Aberrant Right Posterior Duct Obstruction Developing after Placement of a Covered Self-Expandable Metallic Stent in a Patient with Distal Biliary Obstruction |
title_short | Endoscopic Ultrasound-Guided Gallbladder Drainage for Aberrant Right Posterior Duct Obstruction Developing after Placement of a Covered Self-Expandable Metallic Stent in a Patient with Distal Biliary Obstruction |
title_sort | endoscopic ultrasound-guided gallbladder drainage for aberrant right posterior duct obstruction developing after placement of a covered self-expandable metallic stent in a patient with distal biliary obstruction |
topic | Single Case |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6323387/ https://www.ncbi.nlm.nih.gov/pubmed/30631259 http://dx.doi.org/10.1159/000492215 |
work_keys_str_mv | AT suzukiyuko endoscopicultrasoundguidedgallbladderdrainageforaberrantrightposteriorductobstructiondevelopingafterplacementofacoveredselfexpandablemetallicstentinapatientwithdistalbiliaryobstruction AT hashimotoyusuke endoscopicultrasoundguidedgallbladderdrainageforaberrantrightposteriorductobstructiondevelopingafterplacementofacoveredselfexpandablemetallicstentinapatientwithdistalbiliaryobstruction AT shibukitaro endoscopicultrasoundguidedgallbladderdrainageforaberrantrightposteriorductobstructiondevelopingafterplacementofacoveredselfexpandablemetallicstentinapatientwithdistalbiliaryobstruction AT kanmotoyasu endoscopicultrasoundguidedgallbladderdrainageforaberrantrightposteriorductobstructiondevelopingafterplacementofacoveredselfexpandablemetallicstentinapatientwithdistalbiliaryobstruction AT kimuragen endoscopicultrasoundguidedgallbladderdrainageforaberrantrightposteriorductobstructiondevelopingafterplacementofacoveredselfexpandablemetallicstentinapatientwithdistalbiliaryobstruction AT umemotokumiko endoscopicultrasoundguidedgallbladderdrainageforaberrantrightposteriorductobstructiondevelopingafterplacementofacoveredselfexpandablemetallicstentinapatientwithdistalbiliaryobstruction AT watanabekazuo endoscopicultrasoundguidedgallbladderdrainageforaberrantrightposteriorductobstructiondevelopingafterplacementofacoveredselfexpandablemetallicstentinapatientwithdistalbiliaryobstruction AT sasakimitsuhito endoscopicultrasoundguidedgallbladderdrainageforaberrantrightposteriorductobstructiondevelopingafterplacementofacoveredselfexpandablemetallicstentinapatientwithdistalbiliaryobstruction AT takahashihideaki endoscopicultrasoundguidedgallbladderdrainageforaberrantrightposteriorductobstructiondevelopingafterplacementofacoveredselfexpandablemetallicstentinapatientwithdistalbiliaryobstruction AT imaokahiroshi endoscopicultrasoundguidedgallbladderdrainageforaberrantrightposteriorductobstructiondevelopingafterplacementofacoveredselfexpandablemetallicstentinapatientwithdistalbiliaryobstruction AT ohnoizumi endoscopicultrasoundguidedgallbladderdrainageforaberrantrightposteriorductobstructiondevelopingafterplacementofacoveredselfexpandablemetallicstentinapatientwithdistalbiliaryobstruction AT mitsunagashuichi endoscopicultrasoundguidedgallbladderdrainageforaberrantrightposteriorductobstructiondevelopingafterplacementofacoveredselfexpandablemetallicstentinapatientwithdistalbiliaryobstruction AT ikedamasafumi endoscopicultrasoundguidedgallbladderdrainageforaberrantrightposteriorductobstructiondevelopingafterplacementofacoveredselfexpandablemetallicstentinapatientwithdistalbiliaryobstruction |