The evaluation of intraocular pressure fluctuation in glaucoma subjects during submaximal exercise using an ocular telemetry sensor
PURPOSE: To evaluate the effect of acute submaximal exercise on intraocular pressure (IOP) fluctuations in open-angle glaucoma (OAG) subjects using an ocular telemetry sensor (OTS, Sensimed TriggerFish(®)). METHODS: Twelve OAG subjects aged 45–65 years with no medical limitation for exercise were in...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6324145/ https://www.ncbi.nlm.nih.gov/pubmed/30574900 http://dx.doi.org/10.4103/ijo.IJO_585_18 |
_version_ | 1783385921682407424 |
---|---|
author | Bozkurt, Banu Okudan, Nilsel Belviranli, Muaz Oflaz, Ayse Bozkurt |
author_facet | Bozkurt, Banu Okudan, Nilsel Belviranli, Muaz Oflaz, Ayse Bozkurt |
author_sort | Bozkurt, Banu |
collection | PubMed |
description | PURPOSE: To evaluate the effect of acute submaximal exercise on intraocular pressure (IOP) fluctuations in open-angle glaucoma (OAG) subjects using an ocular telemetry sensor (OTS, Sensimed TriggerFish(®)). METHODS: Twelve OAG subjects aged 45–65 years with no medical limitation for exercise were included in this prospective study. A submaximal exercise test was performed using a cycle ergometer for 20 min during which OTS voltages and metabolic parameters were recorded continuously. IOP voltages taken before, during, and after exercise were compared using the Friedman test and correlations with the metabolic parameters were evaluated using the Spearman analysis. RESULTS: In two subjects, the OTS stopped functioning after a few hours. Median OTS measurements were 37.60 mVeq 10 min before exercise [interquartile range (IQR) 137.27], 51.75 (IQR 121.2), 62.35 (IQR 123.72), 54.6 (IQR 141.3), and 59.7 mVeq (IQR 196.7) during exercise (4 time points, 5 min apart), and 50.7 (IQR 147.35) and 64.2 mVeq (IQR 103.25) 10 and 30 min after exercise and the change was statistically non-significant (P = 0.66). No correlations were found between OTS and metabolic parameters measured at the same time points (P > 0.05). Nocturnal acrophase pattern was detected in five subjects (50%), diurnal acrophase in two patients, and double-hump in two patients. Median IOP voltages in the morning, afternoon/evening, and night were 335.84, 149.15, and 341.38 mVeq, respectively (P < 0.001). CONCLUSION: Continuous IOP monitoring did not reveal a remarkable voltage change in OAG patients during or immediately after exercise, but nocturnal IOP peaks in half of the patients. |
format | Online Article Text |
id | pubmed-6324145 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-63241452019-01-25 The evaluation of intraocular pressure fluctuation in glaucoma subjects during submaximal exercise using an ocular telemetry sensor Bozkurt, Banu Okudan, Nilsel Belviranli, Muaz Oflaz, Ayse Bozkurt Indian J Ophthalmol Original Article PURPOSE: To evaluate the effect of acute submaximal exercise on intraocular pressure (IOP) fluctuations in open-angle glaucoma (OAG) subjects using an ocular telemetry sensor (OTS, Sensimed TriggerFish(®)). METHODS: Twelve OAG subjects aged 45–65 years with no medical limitation for exercise were included in this prospective study. A submaximal exercise test was performed using a cycle ergometer for 20 min during which OTS voltages and metabolic parameters were recorded continuously. IOP voltages taken before, during, and after exercise were compared using the Friedman test and correlations with the metabolic parameters were evaluated using the Spearman analysis. RESULTS: In two subjects, the OTS stopped functioning after a few hours. Median OTS measurements were 37.60 mVeq 10 min before exercise [interquartile range (IQR) 137.27], 51.75 (IQR 121.2), 62.35 (IQR 123.72), 54.6 (IQR 141.3), and 59.7 mVeq (IQR 196.7) during exercise (4 time points, 5 min apart), and 50.7 (IQR 147.35) and 64.2 mVeq (IQR 103.25) 10 and 30 min after exercise and the change was statistically non-significant (P = 0.66). No correlations were found between OTS and metabolic parameters measured at the same time points (P > 0.05). Nocturnal acrophase pattern was detected in five subjects (50%), diurnal acrophase in two patients, and double-hump in two patients. Median IOP voltages in the morning, afternoon/evening, and night were 335.84, 149.15, and 341.38 mVeq, respectively (P < 0.001). CONCLUSION: Continuous IOP monitoring did not reveal a remarkable voltage change in OAG patients during or immediately after exercise, but nocturnal IOP peaks in half of the patients. Medknow Publications & Media Pvt Ltd 2019-01 /pmc/articles/PMC6324145/ /pubmed/30574900 http://dx.doi.org/10.4103/ijo.IJO_585_18 Text en Copyright: © 2018 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Bozkurt, Banu Okudan, Nilsel Belviranli, Muaz Oflaz, Ayse Bozkurt The evaluation of intraocular pressure fluctuation in glaucoma subjects during submaximal exercise using an ocular telemetry sensor |
title | The evaluation of intraocular pressure fluctuation in glaucoma subjects during submaximal exercise using an ocular telemetry sensor |
title_full | The evaluation of intraocular pressure fluctuation in glaucoma subjects during submaximal exercise using an ocular telemetry sensor |
title_fullStr | The evaluation of intraocular pressure fluctuation in glaucoma subjects during submaximal exercise using an ocular telemetry sensor |
title_full_unstemmed | The evaluation of intraocular pressure fluctuation in glaucoma subjects during submaximal exercise using an ocular telemetry sensor |
title_short | The evaluation of intraocular pressure fluctuation in glaucoma subjects during submaximal exercise using an ocular telemetry sensor |
title_sort | evaluation of intraocular pressure fluctuation in glaucoma subjects during submaximal exercise using an ocular telemetry sensor |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6324145/ https://www.ncbi.nlm.nih.gov/pubmed/30574900 http://dx.doi.org/10.4103/ijo.IJO_585_18 |
work_keys_str_mv | AT bozkurtbanu theevaluationofintraocularpressurefluctuationinglaucomasubjectsduringsubmaximalexerciseusinganoculartelemetrysensor AT okudannilsel theevaluationofintraocularpressurefluctuationinglaucomasubjectsduringsubmaximalexerciseusinganoculartelemetrysensor AT belviranlimuaz theevaluationofintraocularpressurefluctuationinglaucomasubjectsduringsubmaximalexerciseusinganoculartelemetrysensor AT oflazaysebozkurt theevaluationofintraocularpressurefluctuationinglaucomasubjectsduringsubmaximalexerciseusinganoculartelemetrysensor AT bozkurtbanu evaluationofintraocularpressurefluctuationinglaucomasubjectsduringsubmaximalexerciseusinganoculartelemetrysensor AT okudannilsel evaluationofintraocularpressurefluctuationinglaucomasubjectsduringsubmaximalexerciseusinganoculartelemetrysensor AT belviranlimuaz evaluationofintraocularpressurefluctuationinglaucomasubjectsduringsubmaximalexerciseusinganoculartelemetrysensor AT oflazaysebozkurt evaluationofintraocularpressurefluctuationinglaucomasubjectsduringsubmaximalexerciseusinganoculartelemetrysensor |