Cargando…

Evaluation of Digital Breast Tomosynthesis as Replacement of Full-Field Digital Mammography Using an In Silico Imaging Trial

IMPORTANCE: Expensive and lengthy clinical trials can delay regulatory evaluation of innovative technologies, affecting patient access to high-quality medical products. Simulation is increasingly being used in product development but rarely in regulatory applications. OBJECTIVES: To conduct a comput...

Descripción completa

Detalles Bibliográficos
Autores principales: Badano, Aldo, Graff, Christian G., Badal, Andreu, Sharma, Diksha, Zeng, Rongping, Samuelson, Frank W., Glick, Stephen J., Myers, Kyle J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Medical Association 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6324392/
https://www.ncbi.nlm.nih.gov/pubmed/30646401
http://dx.doi.org/10.1001/jamanetworkopen.2018.5474
_version_ 1783385962424827904
author Badano, Aldo
Graff, Christian G.
Badal, Andreu
Sharma, Diksha
Zeng, Rongping
Samuelson, Frank W.
Glick, Stephen J.
Myers, Kyle J.
author_facet Badano, Aldo
Graff, Christian G.
Badal, Andreu
Sharma, Diksha
Zeng, Rongping
Samuelson, Frank W.
Glick, Stephen J.
Myers, Kyle J.
author_sort Badano, Aldo
collection PubMed
description IMPORTANCE: Expensive and lengthy clinical trials can delay regulatory evaluation of innovative technologies, affecting patient access to high-quality medical products. Simulation is increasingly being used in product development but rarely in regulatory applications. OBJECTIVES: To conduct a computer-simulated imaging trial evaluating digital breast tomosynthesis (DBT) as a replacement for digital mammography (DM) and to compare the results with a comparative clinical trial. DESIGN, SETTING, AND PARTICIPANTS: The simulated Virtual Imaging Clinical Trial for Regulatory Evaluation (VICTRE) trial was designed to replicate a clinical trial that used human patients and radiologists. Images obtained with in silico versions of DM and DBT systems via fast Monte Carlo x-ray transport were interpreted by a computational reader detecting the presence of lesions. A total of 2986 synthetic image–based virtual patients with breast sizes and radiographic densities representative of a screening population and compressed thicknesses from 3.5 to 6 cm were generated using an analytic approach in which anatomical structures are randomly created within a predefined breast volume and compressed in the craniocaudal orientation. A positive cohort contained a digitally inserted microcalcification cluster or spiculated mass. MAIN OUTCOMES AND MEASURES: The trial end point was the difference in area under the receiver operating characteristic curve between modalities for lesion detection. The trial was sized for an SE of 0.01 in the change in area under the curve (AUC), half the uncertainty in the comparative clinical trial. RESULTS: In this trial, computational readers analyzed 31 055 DM and 27 960 DBT cases from 2986 virtual patients with the following Breast Imaging Reporting and Data System densities: 286 (9.6%) extremely dense, 1200 (40.2%) heterogeneously dense, 1200 (40.2%) scattered fibroglandular densities, and 300 (10.0%) almost entirely fat. The mean (SE) change in AUC was 0.0587 (0.0062) (P < .001) in favor of DBT. The change in AUC was larger for masses (mean [SE], 0.0903 [0.008]) than for calcifications (mean [SE], 0.0268 [0.004]), which was consistent with the findings of the comparative trial (mean [SE], 0.065 [0.017] for masses and −0.047 [0.032] for calcifications). CONCLUSIONS AND RELEVANCE: The results of the simulated VICTRE trial are consistent with the performance seen in the comparative trial. While further research is needed to assess the generalizability of these findings, in silico imaging trials represent a viable source of regulatory evidence for imaging devices.
format Online
Article
Text
id pubmed-6324392
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher American Medical Association
record_format MEDLINE/PubMed
spelling pubmed-63243922019-01-22 Evaluation of Digital Breast Tomosynthesis as Replacement of Full-Field Digital Mammography Using an In Silico Imaging Trial Badano, Aldo Graff, Christian G. Badal, Andreu Sharma, Diksha Zeng, Rongping Samuelson, Frank W. Glick, Stephen J. Myers, Kyle J. JAMA Netw Open Original Investigation IMPORTANCE: Expensive and lengthy clinical trials can delay regulatory evaluation of innovative technologies, affecting patient access to high-quality medical products. Simulation is increasingly being used in product development but rarely in regulatory applications. OBJECTIVES: To conduct a computer-simulated imaging trial evaluating digital breast tomosynthesis (DBT) as a replacement for digital mammography (DM) and to compare the results with a comparative clinical trial. DESIGN, SETTING, AND PARTICIPANTS: The simulated Virtual Imaging Clinical Trial for Regulatory Evaluation (VICTRE) trial was designed to replicate a clinical trial that used human patients and radiologists. Images obtained with in silico versions of DM and DBT systems via fast Monte Carlo x-ray transport were interpreted by a computational reader detecting the presence of lesions. A total of 2986 synthetic image–based virtual patients with breast sizes and radiographic densities representative of a screening population and compressed thicknesses from 3.5 to 6 cm were generated using an analytic approach in which anatomical structures are randomly created within a predefined breast volume and compressed in the craniocaudal orientation. A positive cohort contained a digitally inserted microcalcification cluster or spiculated mass. MAIN OUTCOMES AND MEASURES: The trial end point was the difference in area under the receiver operating characteristic curve between modalities for lesion detection. The trial was sized for an SE of 0.01 in the change in area under the curve (AUC), half the uncertainty in the comparative clinical trial. RESULTS: In this trial, computational readers analyzed 31 055 DM and 27 960 DBT cases from 2986 virtual patients with the following Breast Imaging Reporting and Data System densities: 286 (9.6%) extremely dense, 1200 (40.2%) heterogeneously dense, 1200 (40.2%) scattered fibroglandular densities, and 300 (10.0%) almost entirely fat. The mean (SE) change in AUC was 0.0587 (0.0062) (P < .001) in favor of DBT. The change in AUC was larger for masses (mean [SE], 0.0903 [0.008]) than for calcifications (mean [SE], 0.0268 [0.004]), which was consistent with the findings of the comparative trial (mean [SE], 0.065 [0.017] for masses and −0.047 [0.032] for calcifications). CONCLUSIONS AND RELEVANCE: The results of the simulated VICTRE trial are consistent with the performance seen in the comparative trial. While further research is needed to assess the generalizability of these findings, in silico imaging trials represent a viable source of regulatory evidence for imaging devices. American Medical Association 2018-11-30 /pmc/articles/PMC6324392/ /pubmed/30646401 http://dx.doi.org/10.1001/jamanetworkopen.2018.5474 Text en Copyright 2018 Badano A et al. JAMA Network Open. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the CC-BY License.
spellingShingle Original Investigation
Badano, Aldo
Graff, Christian G.
Badal, Andreu
Sharma, Diksha
Zeng, Rongping
Samuelson, Frank W.
Glick, Stephen J.
Myers, Kyle J.
Evaluation of Digital Breast Tomosynthesis as Replacement of Full-Field Digital Mammography Using an In Silico Imaging Trial
title Evaluation of Digital Breast Tomosynthesis as Replacement of Full-Field Digital Mammography Using an In Silico Imaging Trial
title_full Evaluation of Digital Breast Tomosynthesis as Replacement of Full-Field Digital Mammography Using an In Silico Imaging Trial
title_fullStr Evaluation of Digital Breast Tomosynthesis as Replacement of Full-Field Digital Mammography Using an In Silico Imaging Trial
title_full_unstemmed Evaluation of Digital Breast Tomosynthesis as Replacement of Full-Field Digital Mammography Using an In Silico Imaging Trial
title_short Evaluation of Digital Breast Tomosynthesis as Replacement of Full-Field Digital Mammography Using an In Silico Imaging Trial
title_sort evaluation of digital breast tomosynthesis as replacement of full-field digital mammography using an in silico imaging trial
topic Original Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6324392/
https://www.ncbi.nlm.nih.gov/pubmed/30646401
http://dx.doi.org/10.1001/jamanetworkopen.2018.5474
work_keys_str_mv AT badanoaldo evaluationofdigitalbreasttomosynthesisasreplacementoffullfielddigitalmammographyusinganinsilicoimagingtrial
AT graffchristiang evaluationofdigitalbreasttomosynthesisasreplacementoffullfielddigitalmammographyusinganinsilicoimagingtrial
AT badalandreu evaluationofdigitalbreasttomosynthesisasreplacementoffullfielddigitalmammographyusinganinsilicoimagingtrial
AT sharmadiksha evaluationofdigitalbreasttomosynthesisasreplacementoffullfielddigitalmammographyusinganinsilicoimagingtrial
AT zengrongping evaluationofdigitalbreasttomosynthesisasreplacementoffullfielddigitalmammographyusinganinsilicoimagingtrial
AT samuelsonfrankw evaluationofdigitalbreasttomosynthesisasreplacementoffullfielddigitalmammographyusinganinsilicoimagingtrial
AT glickstephenj evaluationofdigitalbreasttomosynthesisasreplacementoffullfielddigitalmammographyusinganinsilicoimagingtrial
AT myerskylej evaluationofdigitalbreasttomosynthesisasreplacementoffullfielddigitalmammographyusinganinsilicoimagingtrial