Cargando…
Evaluation of Artificial Intelligence–Based Grading of Diabetic Retinopathy in Primary Care
IMPORTANCE: There has been wide interest in using artificial intelligence (AI)–based grading of retinal images to identify diabetic retinopathy, but such a system has never been deployed and evaluated in clinical practice. OBJECTIVE: To describe the performance of an AI system for diabetic retinopat...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Medical Association
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6324474/ https://www.ncbi.nlm.nih.gov/pubmed/30646178 http://dx.doi.org/10.1001/jamanetworkopen.2018.2665 |
_version_ | 1783385981399859200 |
---|---|
author | Kanagasingam, Yogesan Xiao, Di Vignarajan, Janardhan Preetham, Amita Tay-Kearney, Mei-Ling Mehrotra, Ateev |
author_facet | Kanagasingam, Yogesan Xiao, Di Vignarajan, Janardhan Preetham, Amita Tay-Kearney, Mei-Ling Mehrotra, Ateev |
author_sort | Kanagasingam, Yogesan |
collection | PubMed |
description | IMPORTANCE: There has been wide interest in using artificial intelligence (AI)–based grading of retinal images to identify diabetic retinopathy, but such a system has never been deployed and evaluated in clinical practice. OBJECTIVE: To describe the performance of an AI system for diabetic retinopathy deployed in a primary care practice. DESIGN, SETTING, AND PARTICIPANTS: Diagnostic study of patients with diabetes seen at a primary care practice with 4 physicians in Western Australia between December 1, 2016, and May 31, 2017. A total of 193 patients consented for the study and had retinal photographs taken of their eyes. Three hundred eighty-six images were evaluated by both the AI-based system and an ophthalmologist. MAIN OUTCOMES AND MEASURES: Sensitivity and specificity of the AI system compared with the gold standard of ophthalmologist evaluation. RESULTS: Of the 193 patients (93 [48%] female; mean [SD] age, 55 [17] years [range, 18-87 years]), the AI system judged 17 as having diabetic retinopathy of sufficient severity to require referral. The system correctly identified 2 patients with true disease and misclassified 15 as having disease (false-positives). The resulting specificity was 92% (95% CI, 87%-96%), and the positive predictive value was 12% (95% CI, 8%-18%). Many false-positives were driven by inadequate image quality (eg, dirty lens) and sheen reflections. CONCLUSIONS AND RELEVANCE: The results demonstrate both the potential and the challenges of using AI systems to identify diabetic retinopathy in clinical practice. Key challenges include the low incidence rate of disease and the related high false-positive rate as well as poor image quality. Further evaluations of AI systems in primary care are needed. |
format | Online Article Text |
id | pubmed-6324474 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | American Medical Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-63244742019-01-22 Evaluation of Artificial Intelligence–Based Grading of Diabetic Retinopathy in Primary Care Kanagasingam, Yogesan Xiao, Di Vignarajan, Janardhan Preetham, Amita Tay-Kearney, Mei-Ling Mehrotra, Ateev JAMA Netw Open Original Investigation IMPORTANCE: There has been wide interest in using artificial intelligence (AI)–based grading of retinal images to identify diabetic retinopathy, but such a system has never been deployed and evaluated in clinical practice. OBJECTIVE: To describe the performance of an AI system for diabetic retinopathy deployed in a primary care practice. DESIGN, SETTING, AND PARTICIPANTS: Diagnostic study of patients with diabetes seen at a primary care practice with 4 physicians in Western Australia between December 1, 2016, and May 31, 2017. A total of 193 patients consented for the study and had retinal photographs taken of their eyes. Three hundred eighty-six images were evaluated by both the AI-based system and an ophthalmologist. MAIN OUTCOMES AND MEASURES: Sensitivity and specificity of the AI system compared with the gold standard of ophthalmologist evaluation. RESULTS: Of the 193 patients (93 [48%] female; mean [SD] age, 55 [17] years [range, 18-87 years]), the AI system judged 17 as having diabetic retinopathy of sufficient severity to require referral. The system correctly identified 2 patients with true disease and misclassified 15 as having disease (false-positives). The resulting specificity was 92% (95% CI, 87%-96%), and the positive predictive value was 12% (95% CI, 8%-18%). Many false-positives were driven by inadequate image quality (eg, dirty lens) and sheen reflections. CONCLUSIONS AND RELEVANCE: The results demonstrate both the potential and the challenges of using AI systems to identify diabetic retinopathy in clinical practice. Key challenges include the low incidence rate of disease and the related high false-positive rate as well as poor image quality. Further evaluations of AI systems in primary care are needed. American Medical Association 2018-09-28 /pmc/articles/PMC6324474/ /pubmed/30646178 http://dx.doi.org/10.1001/jamanetworkopen.2018.2665 Text en Copyright 2018 Kanagasingam Y et al. JAMA Network Open. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the CC-BY License. |
spellingShingle | Original Investigation Kanagasingam, Yogesan Xiao, Di Vignarajan, Janardhan Preetham, Amita Tay-Kearney, Mei-Ling Mehrotra, Ateev Evaluation of Artificial Intelligence–Based Grading of Diabetic Retinopathy in Primary Care |
title | Evaluation of Artificial Intelligence–Based Grading of Diabetic Retinopathy in Primary Care |
title_full | Evaluation of Artificial Intelligence–Based Grading of Diabetic Retinopathy in Primary Care |
title_fullStr | Evaluation of Artificial Intelligence–Based Grading of Diabetic Retinopathy in Primary Care |
title_full_unstemmed | Evaluation of Artificial Intelligence–Based Grading of Diabetic Retinopathy in Primary Care |
title_short | Evaluation of Artificial Intelligence–Based Grading of Diabetic Retinopathy in Primary Care |
title_sort | evaluation of artificial intelligence–based grading of diabetic retinopathy in primary care |
topic | Original Investigation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6324474/ https://www.ncbi.nlm.nih.gov/pubmed/30646178 http://dx.doi.org/10.1001/jamanetworkopen.2018.2665 |
work_keys_str_mv | AT kanagasingamyogesan evaluationofartificialintelligencebasedgradingofdiabeticretinopathyinprimarycare AT xiaodi evaluationofartificialintelligencebasedgradingofdiabeticretinopathyinprimarycare AT vignarajanjanardhan evaluationofartificialintelligencebasedgradingofdiabeticretinopathyinprimarycare AT preethamamita evaluationofartificialintelligencebasedgradingofdiabeticretinopathyinprimarycare AT taykearneymeiling evaluationofartificialintelligencebasedgradingofdiabeticretinopathyinprimarycare AT mehrotraateev evaluationofartificialintelligencebasedgradingofdiabeticretinopathyinprimarycare |