Legionnaires Disease Surveillance in US Department of Veterans Affairs Medical Facilities and Assessment of Health Care Facility Association
IMPORTANCE: Legionnaires disease (LD) incidence is increasing in the United States. Health care facilities are a high-risk setting for transmission of Legionella bacteria from building water systems to occupants. However, the contribution of LD in health care facilities to national LD rates is not w...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Medical Association
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6324594/ https://www.ncbi.nlm.nih.gov/pubmed/30646071 http://dx.doi.org/10.1001/jamanetworkopen.2018.0230 |
_version_ | 1783386000350773248 |
---|---|
author | Gamage, Shantini D. Ambrose, Meredith Kralovic, Stephen M. Simbartl, Loretta A. Roselle, Gary A. |
author_facet | Gamage, Shantini D. Ambrose, Meredith Kralovic, Stephen M. Simbartl, Loretta A. Roselle, Gary A. |
author_sort | Gamage, Shantini D. |
collection | PubMed |
description | IMPORTANCE: Legionnaires disease (LD) incidence is increasing in the United States. Health care facilities are a high-risk setting for transmission of Legionella bacteria from building water systems to occupants. However, the contribution of LD in health care facilities to national LD rates is not well characterized. OBJECTIVES: To determine the burden of LD in US Department of Veterans Affairs (VA) patients and to assess the amount of LD with VA exposure. DESIGN, SETTING, AND PARTICIPANTS: Retrospective cohort study of reported LD data in VA medical facilities in a national VA LD surveillance system from January 1, 2014, to December 31, 2016. The study population included total veteran enrollees and enrollees who used the VA health care system. MAIN OUTCOMES AND MEASURES: The primary outcome was assessment of annual LD rates, categorized by VA and non-VA exposure. Legionnaires disease rates for cases with VA exposure were determined on both population and exposure potential levels. Rates by VA exposure potential were calculated using inpatient bed days of care, long-term care resident days, or outpatient encounters. In addition, types and amounts of LD diagnostic testing were calculated. Case and testing data were analyzed nationally and regionally. RESULTS: There were 491 LD cases in the case report surveillance system from January 1, 2014, to December 31, 2016. Most cases (447 [91%]) had no VA exposure or only outpatient VA exposure. The remaining 44 cases had VA exposure from overnight stays. Total LD rates from January 1, 2014, to December 31, 2016, increased for all VA enrollees (from 1.5 to 2.0 per 100 000 enrollees; P = .04) and for users of VA health care (2.3 to 3.0 per 100 000 enrollees; P = .04). The LD rate for the subset who had no VA exposure also increased (0.90 to 1.47 per 100 000 enrollees; P < .001). In contrast, the LD rate for patients with VA overnight stay decreased on a population level (5.0 to 2.3 per 100 000 enrollees; P < .001) and an exposure level (0.31 to 0.15 per 100 000 enrollees; P < .001). Regionally, the eastern United States had the highest LD rates. The urine antigen test was the most used LD diagnostic method; 49 805 tests were performed in 2015-2016 with 335 positive results (0.67%). CONCLUSIONS AND RELEVANCE: Data in the VA LD databases showed an increase in overall LD rates over the 3 years, driven by increases in rates of non-VA LD. Inpatient VA-associated LD rates decreased, suggesting that the VA’s LD prevention efforts have contributed to improved patient safety. |
format | Online Article Text |
id | pubmed-6324594 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | American Medical Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-63245942019-01-22 Legionnaires Disease Surveillance in US Department of Veterans Affairs Medical Facilities and Assessment of Health Care Facility Association Gamage, Shantini D. Ambrose, Meredith Kralovic, Stephen M. Simbartl, Loretta A. Roselle, Gary A. JAMA Netw Open Original Investigation IMPORTANCE: Legionnaires disease (LD) incidence is increasing in the United States. Health care facilities are a high-risk setting for transmission of Legionella bacteria from building water systems to occupants. However, the contribution of LD in health care facilities to national LD rates is not well characterized. OBJECTIVES: To determine the burden of LD in US Department of Veterans Affairs (VA) patients and to assess the amount of LD with VA exposure. DESIGN, SETTING, AND PARTICIPANTS: Retrospective cohort study of reported LD data in VA medical facilities in a national VA LD surveillance system from January 1, 2014, to December 31, 2016. The study population included total veteran enrollees and enrollees who used the VA health care system. MAIN OUTCOMES AND MEASURES: The primary outcome was assessment of annual LD rates, categorized by VA and non-VA exposure. Legionnaires disease rates for cases with VA exposure were determined on both population and exposure potential levels. Rates by VA exposure potential were calculated using inpatient bed days of care, long-term care resident days, or outpatient encounters. In addition, types and amounts of LD diagnostic testing were calculated. Case and testing data were analyzed nationally and regionally. RESULTS: There were 491 LD cases in the case report surveillance system from January 1, 2014, to December 31, 2016. Most cases (447 [91%]) had no VA exposure or only outpatient VA exposure. The remaining 44 cases had VA exposure from overnight stays. Total LD rates from January 1, 2014, to December 31, 2016, increased for all VA enrollees (from 1.5 to 2.0 per 100 000 enrollees; P = .04) and for users of VA health care (2.3 to 3.0 per 100 000 enrollees; P = .04). The LD rate for the subset who had no VA exposure also increased (0.90 to 1.47 per 100 000 enrollees; P < .001). In contrast, the LD rate for patients with VA overnight stay decreased on a population level (5.0 to 2.3 per 100 000 enrollees; P < .001) and an exposure level (0.31 to 0.15 per 100 000 enrollees; P < .001). Regionally, the eastern United States had the highest LD rates. The urine antigen test was the most used LD diagnostic method; 49 805 tests were performed in 2015-2016 with 335 positive results (0.67%). CONCLUSIONS AND RELEVANCE: Data in the VA LD databases showed an increase in overall LD rates over the 3 years, driven by increases in rates of non-VA LD. Inpatient VA-associated LD rates decreased, suggesting that the VA’s LD prevention efforts have contributed to improved patient safety. American Medical Association 2018-06-15 /pmc/articles/PMC6324594/ /pubmed/30646071 http://dx.doi.org/10.1001/jamanetworkopen.2018.0230 Text en Copyright 2018 Gamage SD et al. JAMA Network Open. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the CC-BY License. |
spellingShingle | Original Investigation Gamage, Shantini D. Ambrose, Meredith Kralovic, Stephen M. Simbartl, Loretta A. Roselle, Gary A. Legionnaires Disease Surveillance in US Department of Veterans Affairs Medical Facilities and Assessment of Health Care Facility Association |
title | Legionnaires Disease Surveillance in US Department of Veterans Affairs Medical Facilities and Assessment of Health Care Facility Association |
title_full | Legionnaires Disease Surveillance in US Department of Veterans Affairs Medical Facilities and Assessment of Health Care Facility Association |
title_fullStr | Legionnaires Disease Surveillance in US Department of Veterans Affairs Medical Facilities and Assessment of Health Care Facility Association |
title_full_unstemmed | Legionnaires Disease Surveillance in US Department of Veterans Affairs Medical Facilities and Assessment of Health Care Facility Association |
title_short | Legionnaires Disease Surveillance in US Department of Veterans Affairs Medical Facilities and Assessment of Health Care Facility Association |
title_sort | legionnaires disease surveillance in us department of veterans affairs medical facilities and assessment of health care facility association |
topic | Original Investigation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6324594/ https://www.ncbi.nlm.nih.gov/pubmed/30646071 http://dx.doi.org/10.1001/jamanetworkopen.2018.0230 |
work_keys_str_mv | AT gamageshantinid legionnairesdiseasesurveillanceinusdepartmentofveteransaffairsmedicalfacilitiesandassessmentofhealthcarefacilityassociation AT ambrosemeredith legionnairesdiseasesurveillanceinusdepartmentofveteransaffairsmedicalfacilitiesandassessmentofhealthcarefacilityassociation AT kralovicstephenm legionnairesdiseasesurveillanceinusdepartmentofveteransaffairsmedicalfacilitiesandassessmentofhealthcarefacilityassociation AT simbartllorettaa legionnairesdiseasesurveillanceinusdepartmentofveteransaffairsmedicalfacilitiesandassessmentofhealthcarefacilityassociation AT rosellegarya legionnairesdiseasesurveillanceinusdepartmentofveteransaffairsmedicalfacilitiesandassessmentofhealthcarefacilityassociation |