Cargando…
Polyester Grafts Are a Risk Factor for Postimplantation Syndrome after Abdominal Endovascular Aneurysm Repair: Retrospective Analysis for Polyester Graft, Excluder®, and Endologix Powerlink®/AFX®
Objective: Postimplantation syndrome (PIS) is a postoperative syndrome that occurs after endovascular aneurysm repair (EVAR), accompanied by high fever, leukocytosis, and high serum C-reactive protein (CRP). Its pathogenesis and clinical meaning are still under discussion. Here, we evaluate the rela...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6326045/ https://www.ncbi.nlm.nih.gov/pubmed/30637008 http://dx.doi.org/10.3400/avd.oa.18-00058 |
_version_ | 1783386235777056768 |
---|---|
author | Ito, Eisaku Toya, Naoki Fukushima, Soichiro Nishie, Ryosuke Akiba, Tadashi Ohki, Takao |
author_facet | Ito, Eisaku Toya, Naoki Fukushima, Soichiro Nishie, Ryosuke Akiba, Tadashi Ohki, Takao |
author_sort | Ito, Eisaku |
collection | PubMed |
description | Objective: Postimplantation syndrome (PIS) is a postoperative syndrome that occurs after endovascular aneurysm repair (EVAR), accompanied by high fever, leukocytosis, and high serum C-reactive protein (CRP). Its pathogenesis and clinical meaning are still under discussion. Here, we evaluate the relationship between postoperative fever after EVAR and graft fabric focusing on Endologix Powerlink® and AFX® (EPL/AFX). Materials and Methods: From January 2015 to July 2017, data on elective EVAR for abdominal aortic aneurysm (AAA) using mainbody were retrospectively collected. The primary endpoint was maximal postoperative fever. Results: We identified 128 patients who underwent elective EVAR for AAA (105 males, 82%; aged 57–90, median: 74 years). The median maximal postoperative fever was 37.8°C (36.6–39.7°C): polyester graft, 38.2°C (37.1–39.7°C); Excluder®, 37.8°C (36.6–39.2°C); and EPL/AFX, 37.7°C (37–38.7°C). The maximal postoperative fever with a polyester graft was significantly higher than that with an expanded polytetrafluoroethylene (ePTFE) graft (p<0.001). However, there was no difference between Excluder® and EPL/AFX (p=0.214). Conclusion: In this study, it was found that polyester grafts are significantly associated with PIS after elective EVAR for AAA. If patient anatomy is permitted, it may be better to choose the ePTFE graft, especially for patients with a poor general condition. |
format | Online Article Text |
id | pubmed-6326045 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology |
record_format | MEDLINE/PubMed |
spelling | pubmed-63260452019-01-11 Polyester Grafts Are a Risk Factor for Postimplantation Syndrome after Abdominal Endovascular Aneurysm Repair: Retrospective Analysis for Polyester Graft, Excluder®, and Endologix Powerlink®/AFX® Ito, Eisaku Toya, Naoki Fukushima, Soichiro Nishie, Ryosuke Akiba, Tadashi Ohki, Takao Ann Vasc Dis Original Article Objective: Postimplantation syndrome (PIS) is a postoperative syndrome that occurs after endovascular aneurysm repair (EVAR), accompanied by high fever, leukocytosis, and high serum C-reactive protein (CRP). Its pathogenesis and clinical meaning are still under discussion. Here, we evaluate the relationship between postoperative fever after EVAR and graft fabric focusing on Endologix Powerlink® and AFX® (EPL/AFX). Materials and Methods: From January 2015 to July 2017, data on elective EVAR for abdominal aortic aneurysm (AAA) using mainbody were retrospectively collected. The primary endpoint was maximal postoperative fever. Results: We identified 128 patients who underwent elective EVAR for AAA (105 males, 82%; aged 57–90, median: 74 years). The median maximal postoperative fever was 37.8°C (36.6–39.7°C): polyester graft, 38.2°C (37.1–39.7°C); Excluder®, 37.8°C (36.6–39.2°C); and EPL/AFX, 37.7°C (37–38.7°C). The maximal postoperative fever with a polyester graft was significantly higher than that with an expanded polytetrafluoroethylene (ePTFE) graft (p<0.001). However, there was no difference between Excluder® and EPL/AFX (p=0.214). Conclusion: In this study, it was found that polyester grafts are significantly associated with PIS after elective EVAR for AAA. If patient anatomy is permitted, it may be better to choose the ePTFE graft, especially for patients with a poor general condition. Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology 2018-12-25 /pmc/articles/PMC6326045/ /pubmed/30637008 http://dx.doi.org/10.3400/avd.oa.18-00058 Text en Copyright © 2018 Annals of Vascular Diseases http://creativecommons.org/licenses/by-nc-sa/4.0/ ©2018 The Editorial Committee of Annals of Vascular Diseases. This article is distributed under the terms of the Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided the credit of the original work, a link to the license, and indication of any change are properly given, and the original work is not used for commercial purposes. Remixed or transformed contributions must be distributed under the same license as the original. |
spellingShingle | Original Article Ito, Eisaku Toya, Naoki Fukushima, Soichiro Nishie, Ryosuke Akiba, Tadashi Ohki, Takao Polyester Grafts Are a Risk Factor for Postimplantation Syndrome after Abdominal Endovascular Aneurysm Repair: Retrospective Analysis for Polyester Graft, Excluder®, and Endologix Powerlink®/AFX® |
title | Polyester Grafts Are a Risk Factor for Postimplantation Syndrome after Abdominal Endovascular Aneurysm Repair: Retrospective Analysis for Polyester Graft, Excluder®, and Endologix Powerlink®/AFX® |
title_full | Polyester Grafts Are a Risk Factor for Postimplantation Syndrome after Abdominal Endovascular Aneurysm Repair: Retrospective Analysis for Polyester Graft, Excluder®, and Endologix Powerlink®/AFX® |
title_fullStr | Polyester Grafts Are a Risk Factor for Postimplantation Syndrome after Abdominal Endovascular Aneurysm Repair: Retrospective Analysis for Polyester Graft, Excluder®, and Endologix Powerlink®/AFX® |
title_full_unstemmed | Polyester Grafts Are a Risk Factor for Postimplantation Syndrome after Abdominal Endovascular Aneurysm Repair: Retrospective Analysis for Polyester Graft, Excluder®, and Endologix Powerlink®/AFX® |
title_short | Polyester Grafts Are a Risk Factor for Postimplantation Syndrome after Abdominal Endovascular Aneurysm Repair: Retrospective Analysis for Polyester Graft, Excluder®, and Endologix Powerlink®/AFX® |
title_sort | polyester grafts are a risk factor for postimplantation syndrome after abdominal endovascular aneurysm repair: retrospective analysis for polyester graft, excluder®, and endologix powerlink®/afx® |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6326045/ https://www.ncbi.nlm.nih.gov/pubmed/30637008 http://dx.doi.org/10.3400/avd.oa.18-00058 |
work_keys_str_mv | AT itoeisaku polyestergraftsareariskfactorforpostimplantationsyndromeafterabdominalendovascularaneurysmrepairretrospectiveanalysisforpolyestergraftexcluderandendologixpowerlinkafx AT toyanaoki polyestergraftsareariskfactorforpostimplantationsyndromeafterabdominalendovascularaneurysmrepairretrospectiveanalysisforpolyestergraftexcluderandendologixpowerlinkafx AT fukushimasoichiro polyestergraftsareariskfactorforpostimplantationsyndromeafterabdominalendovascularaneurysmrepairretrospectiveanalysisforpolyestergraftexcluderandendologixpowerlinkafx AT nishieryosuke polyestergraftsareariskfactorforpostimplantationsyndromeafterabdominalendovascularaneurysmrepairretrospectiveanalysisforpolyestergraftexcluderandendologixpowerlinkafx AT akibatadashi polyestergraftsareariskfactorforpostimplantationsyndromeafterabdominalendovascularaneurysmrepairretrospectiveanalysisforpolyestergraftexcluderandendologixpowerlinkafx AT ohkitakao polyestergraftsareariskfactorforpostimplantationsyndromeafterabdominalendovascularaneurysmrepairretrospectiveanalysisforpolyestergraftexcluderandendologixpowerlinkafx |