Cargando…
Update on Cardiovascular Echo in Aortic Aneurysm and Dissection
The majority of aortic aneurysms comorbid with atherosclerosis can be asymptomatic and are discovered incidentally on routine physical examination or on imaging studies for other indications. Transthoracic echocardiography is a basic modality to assess patients with coronary artery disease and can b...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6326059/ https://www.ncbi.nlm.nih.gov/pubmed/30636996 http://dx.doi.org/10.3400/avd.ra.18-00112 |
_version_ | 1783386239214288896 |
---|---|
author | Nishigami, Kazuhiro |
author_facet | Nishigami, Kazuhiro |
author_sort | Nishigami, Kazuhiro |
collection | PubMed |
description | The majority of aortic aneurysms comorbid with atherosclerosis can be asymptomatic and are discovered incidentally on routine physical examination or on imaging studies for other indications. Transthoracic echocardiography is a basic modality to assess patients with coronary artery disease and can be used for the screening of aortic aneurysm. Acute aortic dissection is a highly lethal cardiovascular emergency and requires prompt recognition. Although cardiovascular echo has a suboptimal accuracy rate for detecting aortic dissection, it is noninvasive, readily available, and easy to use. Recently, the concept of point-of-care ultrasound (POCUS) refers to the use of portable ultrasound at the patient’s bedside for diagnostic and therapeutic purposes. POCUS could become an important tool in the screening and primary diagnosis for acute aortic dissection. Transesophageal echocardiography (TEE) was established to detect aortic dissection and determine the therapy. However, the use of TEE has decreased with the progress of contrast-enhanced computed tomography. Currently, attention is paid to TEE in the monitoring for the operation of aortic dissection, the use on bedside, and in emergency room, and the precise evaluation of aortic dissection for the patient with a history of allergy of contrast media and/or renal disturbance. |
format | Online Article Text |
id | pubmed-6326059 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology |
record_format | MEDLINE/PubMed |
spelling | pubmed-63260592019-01-11 Update on Cardiovascular Echo in Aortic Aneurysm and Dissection Nishigami, Kazuhiro Ann Vasc Dis Review Article The majority of aortic aneurysms comorbid with atherosclerosis can be asymptomatic and are discovered incidentally on routine physical examination or on imaging studies for other indications. Transthoracic echocardiography is a basic modality to assess patients with coronary artery disease and can be used for the screening of aortic aneurysm. Acute aortic dissection is a highly lethal cardiovascular emergency and requires prompt recognition. Although cardiovascular echo has a suboptimal accuracy rate for detecting aortic dissection, it is noninvasive, readily available, and easy to use. Recently, the concept of point-of-care ultrasound (POCUS) refers to the use of portable ultrasound at the patient’s bedside for diagnostic and therapeutic purposes. POCUS could become an important tool in the screening and primary diagnosis for acute aortic dissection. Transesophageal echocardiography (TEE) was established to detect aortic dissection and determine the therapy. However, the use of TEE has decreased with the progress of contrast-enhanced computed tomography. Currently, attention is paid to TEE in the monitoring for the operation of aortic dissection, the use on bedside, and in emergency room, and the precise evaluation of aortic dissection for the patient with a history of allergy of contrast media and/or renal disturbance. Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology 2018-12-25 /pmc/articles/PMC6326059/ /pubmed/30636996 http://dx.doi.org/10.3400/avd.ra.18-00112 Text en Copyright © 2018 Annals of Vascular Diseases http://creativecommons.org/licenses/by-nc-sa/4.0/ ©2018 The Editorial Committee of Annals of Vascular Diseases. This article is distributed under the terms of the Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided the credit of the original work, a link to the license, and indication of any change are properly given, and the original work is not used for commercial purposes. Remixed or transformed contributions must be distributed under the same license as the original. |
spellingShingle | Review Article Nishigami, Kazuhiro Update on Cardiovascular Echo in Aortic Aneurysm and Dissection |
title | Update on Cardiovascular Echo in Aortic Aneurysm and Dissection |
title_full | Update on Cardiovascular Echo in Aortic Aneurysm and Dissection |
title_fullStr | Update on Cardiovascular Echo in Aortic Aneurysm and Dissection |
title_full_unstemmed | Update on Cardiovascular Echo in Aortic Aneurysm and Dissection |
title_short | Update on Cardiovascular Echo in Aortic Aneurysm and Dissection |
title_sort | update on cardiovascular echo in aortic aneurysm and dissection |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6326059/ https://www.ncbi.nlm.nih.gov/pubmed/30636996 http://dx.doi.org/10.3400/avd.ra.18-00112 |
work_keys_str_mv | AT nishigamikazuhiro updateoncardiovascularechoinaorticaneurysmanddissection |