A tolerability assessment of new respiratory protective devices developed for health care personnel: A randomized simulated clinical study

BACKGROUND: U.S. health care personnel (HCP) have reported that some respiratory protective devices (RPD) commonly used in health care have suboptimal tolerability. Between 2012 and 2016, the U.S. National Institute for Occupational Safety and Health, and the Veterans Health Administration collabora...

Descripción completa

Detalles Bibliográficos
Autores principales: Radonovich, Lewis J., Wizner, Kerri, LaVela, Sherri L., Lee, Martin L., Findley, Kimberly, Yorio, Patrick
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6326489/
https://www.ncbi.nlm.nih.gov/pubmed/30625169
http://dx.doi.org/10.1371/journal.pone.0209559
_version_ 1783386307913842688
author Radonovich, Lewis J.
Wizner, Kerri
LaVela, Sherri L.
Lee, Martin L.
Findley, Kimberly
Yorio, Patrick
author_facet Radonovich, Lewis J.
Wizner, Kerri
LaVela, Sherri L.
Lee, Martin L.
Findley, Kimberly
Yorio, Patrick
author_sort Radonovich, Lewis J.
collection PubMed
description BACKGROUND: U.S. health care personnel (HCP) have reported that some respiratory protective devices (RPD) commonly used in health care have suboptimal tolerability. Between 2012 and 2016, the U.S. National Institute for Occupational Safety and Health, and the Veterans Health Administration collaborated with two respirator manufacturers, Company A and B, to bring new RPD with improved tolerability to the U.S. health care marketplace. The purpose of this study was to compare the tolerability of four new prototype RPD to two models commonly used in U.S. health care delivery. METHODS: A randomized, simulated workplace study was conducted to compare self-reported tolerability of four new prototype RPD (A1, A2, B1, and B2) worn by HCP and two N95 control respirators commonly used in U.S. health care delivery, the 1870 and 1860, manufactured by 3M Corporation. A new survey tool, the Respirator Comfort, Wearing Experience, and Function Instrument (R-COMFI), developed previously in part for the current study, was used as the primary outcome metric. With a maximum total score of 47, lower R-COMFI scores reflected better self-reported tolerability. Poisson regression analyses were used to estimate prototype relative risks compared to controls. RESULTS: Conducted between 2014 and 2015 in two inpatient care rooms at the North Florida/South Georgia Veterans Health System, among 383 participants who enrolled, 335 (87.5%) completed the study. Mean total R-COMFI scores for the 3M 1870, 3M 1860, and prototypes A1, A2, B1, and B2 were 8.26, 9.36, 5.79, 7.70, 6.09, and 5.71, respectively. Compared to the 3M 1870, total R-COMFI unadjusted relative risks (RR) and 95 percent confidence intervals (CI) were A1 (RR 0.70, CI 0.60, 0.82), A2 (RR 0.93, CI 0.82, 1.06), B1 (RR 0.74, CI 0.64, 0.85), and B2 (RR 0.69, CI 0.60, 0.80). Compared to the 3M 1860, prototype total R-COMFI unadjusted RR and 95 percent CI were A1 (RR 0.62, CI 0.53, 0.72), A2 (RR 0.82, CI 0.73, 0.93), B1 (RR 0.65, CI 0.57, 0.74), and B2 (RR 0.61, CI 0.53, 0.70). Similarly, models adjusted for demographic characteristics showed that prototypes A1, B1, and B2 significantly improved tolerability scores compared to both controls, while prototype A2 was significantly improved compared to the 3M 1860. CONCLUSIONS: Compared to the 3M 1870 and 3M 1860, two RPDs commonly used in U.S. health care delivery, tolerability improved for three of four newly developed prototypes in this simulated workplace study. The R-COMFI tool, used in this study to assess tolerability, should be useful for future comparative studies of RPD.
format Online
Article
Text
id pubmed-6326489
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-63264892019-01-18 A tolerability assessment of new respiratory protective devices developed for health care personnel: A randomized simulated clinical study Radonovich, Lewis J. Wizner, Kerri LaVela, Sherri L. Lee, Martin L. Findley, Kimberly Yorio, Patrick PLoS One Research Article BACKGROUND: U.S. health care personnel (HCP) have reported that some respiratory protective devices (RPD) commonly used in health care have suboptimal tolerability. Between 2012 and 2016, the U.S. National Institute for Occupational Safety and Health, and the Veterans Health Administration collaborated with two respirator manufacturers, Company A and B, to bring new RPD with improved tolerability to the U.S. health care marketplace. The purpose of this study was to compare the tolerability of four new prototype RPD to two models commonly used in U.S. health care delivery. METHODS: A randomized, simulated workplace study was conducted to compare self-reported tolerability of four new prototype RPD (A1, A2, B1, and B2) worn by HCP and two N95 control respirators commonly used in U.S. health care delivery, the 1870 and 1860, manufactured by 3M Corporation. A new survey tool, the Respirator Comfort, Wearing Experience, and Function Instrument (R-COMFI), developed previously in part for the current study, was used as the primary outcome metric. With a maximum total score of 47, lower R-COMFI scores reflected better self-reported tolerability. Poisson regression analyses were used to estimate prototype relative risks compared to controls. RESULTS: Conducted between 2014 and 2015 in two inpatient care rooms at the North Florida/South Georgia Veterans Health System, among 383 participants who enrolled, 335 (87.5%) completed the study. Mean total R-COMFI scores for the 3M 1870, 3M 1860, and prototypes A1, A2, B1, and B2 were 8.26, 9.36, 5.79, 7.70, 6.09, and 5.71, respectively. Compared to the 3M 1870, total R-COMFI unadjusted relative risks (RR) and 95 percent confidence intervals (CI) were A1 (RR 0.70, CI 0.60, 0.82), A2 (RR 0.93, CI 0.82, 1.06), B1 (RR 0.74, CI 0.64, 0.85), and B2 (RR 0.69, CI 0.60, 0.80). Compared to the 3M 1860, prototype total R-COMFI unadjusted RR and 95 percent CI were A1 (RR 0.62, CI 0.53, 0.72), A2 (RR 0.82, CI 0.73, 0.93), B1 (RR 0.65, CI 0.57, 0.74), and B2 (RR 0.61, CI 0.53, 0.70). Similarly, models adjusted for demographic characteristics showed that prototypes A1, B1, and B2 significantly improved tolerability scores compared to both controls, while prototype A2 was significantly improved compared to the 3M 1860. CONCLUSIONS: Compared to the 3M 1870 and 3M 1860, two RPDs commonly used in U.S. health care delivery, tolerability improved for three of four newly developed prototypes in this simulated workplace study. The R-COMFI tool, used in this study to assess tolerability, should be useful for future comparative studies of RPD. Public Library of Science 2019-01-09 /pmc/articles/PMC6326489/ /pubmed/30625169 http://dx.doi.org/10.1371/journal.pone.0209559 Text en https://creativecommons.org/publicdomain/zero/1.0/ This is an open access article, free of all copyright, and may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose. The work is made available under the Creative Commons CC0 (https://creativecommons.org/publicdomain/zero/1.0/) public domain dedication.
spellingShingle Research Article
Radonovich, Lewis J.
Wizner, Kerri
LaVela, Sherri L.
Lee, Martin L.
Findley, Kimberly
Yorio, Patrick
A tolerability assessment of new respiratory protective devices developed for health care personnel: A randomized simulated clinical study
title A tolerability assessment of new respiratory protective devices developed for health care personnel: A randomized simulated clinical study
title_full A tolerability assessment of new respiratory protective devices developed for health care personnel: A randomized simulated clinical study
title_fullStr A tolerability assessment of new respiratory protective devices developed for health care personnel: A randomized simulated clinical study
title_full_unstemmed A tolerability assessment of new respiratory protective devices developed for health care personnel: A randomized simulated clinical study
title_short A tolerability assessment of new respiratory protective devices developed for health care personnel: A randomized simulated clinical study
title_sort tolerability assessment of new respiratory protective devices developed for health care personnel: a randomized simulated clinical study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6326489/
https://www.ncbi.nlm.nih.gov/pubmed/30625169
http://dx.doi.org/10.1371/journal.pone.0209559
work_keys_str_mv AT radonovichlewisj atolerabilityassessmentofnewrespiratoryprotectivedevicesdevelopedforhealthcarepersonnelarandomizedsimulatedclinicalstudy
AT wiznerkerri atolerabilityassessmentofnewrespiratoryprotectivedevicesdevelopedforhealthcarepersonnelarandomizedsimulatedclinicalstudy
AT lavelasherril atolerabilityassessmentofnewrespiratoryprotectivedevicesdevelopedforhealthcarepersonnelarandomizedsimulatedclinicalstudy
AT leemartinl atolerabilityassessmentofnewrespiratoryprotectivedevicesdevelopedforhealthcarepersonnelarandomizedsimulatedclinicalstudy
AT findleykimberly atolerabilityassessmentofnewrespiratoryprotectivedevicesdevelopedforhealthcarepersonnelarandomizedsimulatedclinicalstudy
AT yoriopatrick atolerabilityassessmentofnewrespiratoryprotectivedevicesdevelopedforhealthcarepersonnelarandomizedsimulatedclinicalstudy
AT radonovichlewisj tolerabilityassessmentofnewrespiratoryprotectivedevicesdevelopedforhealthcarepersonnelarandomizedsimulatedclinicalstudy
AT wiznerkerri tolerabilityassessmentofnewrespiratoryprotectivedevicesdevelopedforhealthcarepersonnelarandomizedsimulatedclinicalstudy
AT lavelasherril tolerabilityassessmentofnewrespiratoryprotectivedevicesdevelopedforhealthcarepersonnelarandomizedsimulatedclinicalstudy
AT leemartinl tolerabilityassessmentofnewrespiratoryprotectivedevicesdevelopedforhealthcarepersonnelarandomizedsimulatedclinicalstudy
AT findleykimberly tolerabilityassessmentofnewrespiratoryprotectivedevicesdevelopedforhealthcarepersonnelarandomizedsimulatedclinicalstudy
AT yoriopatrick tolerabilityassessmentofnewrespiratoryprotectivedevicesdevelopedforhealthcarepersonnelarandomizedsimulatedclinicalstudy