Cargando…

The Reliability of Reduced Field-of-view DTI for Highly Accurate Quantitative Assessment of Cervical Spinal Cord Tracts

PURPOSE: To compare the accuracy of fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values between reduced FOV or so-called zonally oblique multislice (ZOOM) and conventional diffusion tensor imaging (DTI) in the cervical spinal cord. METHODS: Both ZOOM and conventional DTI were...

Descripción completa

Detalles Bibliográficos
Autores principales: Yokohama, Takumi, Iwasaki, Motoyuki, Oura, Daisuke, Furuya, Sho, Okuaki, Tomoyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese Society for Magnetic Resonance in Medicine 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6326762/
https://www.ncbi.nlm.nih.gov/pubmed/29576582
http://dx.doi.org/10.2463/mrms.mp.2017-0078
_version_ 1783386361566330880
author Yokohama, Takumi
Iwasaki, Motoyuki
Oura, Daisuke
Furuya, Sho
Okuaki, Tomoyuki
author_facet Yokohama, Takumi
Iwasaki, Motoyuki
Oura, Daisuke
Furuya, Sho
Okuaki, Tomoyuki
author_sort Yokohama, Takumi
collection PubMed
description PURPOSE: To compare the accuracy of fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values between reduced FOV or so-called zonally oblique multislice (ZOOM) and conventional diffusion tensor imaging (DTI) in the cervical spinal cord. METHODS: Both ZOOM and conventional DTI were performed on 10 healthy volunteers. Intraclass correlation coefficient (ICC) was used to evaluate the reliability of the measurements obtained. Four radiologists evaluated the FA and ADC values at each cervical cord level and classified the visibility by 4 ranks. The geometric distortion ratios of the long axis and short axis were compared between ZOOM and conventional DTI. The imaging parameters were as follows: b-value = 600 s/mm(2); TR = 4500 ms; TE = 81 ms; FOV = 70 × 47 mm(2) / 200 × 200 mm(2); matrix = 80 × 51 / 128 × 126 (ZOOM and conventional DTI, respectively). The region of interest was carefully drawn inside the spinal cord margin to exclude the spinal cord component, without excluding the white matter fiber tracts. RESULTS: The average FA value decreased in both ZOOM and conventional DTI in lower spinal cord levels; in contrast, the ADC value increased in lower spinal cord levels. Zonally oblique multislice DTI was superior to conventional DTI with regard to inter-rater and intra-rater reliability; further, visibility was better and the standard deviation was smaller in ZOOM DTI. On both the long and short axis, the geometric distortion ratio was lower in ZOOM DTI at all cervical spinal cord levels compared with the conventional DTI. There was a significant difference in the distortion ratios of the long and short axis between ZOOM and conventional DTI. CONCLUSION: Conventional DTI is unreliable owing to its susceptibility to the surrounding magnetic field. ZOOM DTI is reliable for performing highly accurate evaluations.
format Online
Article
Text
id pubmed-6326762
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Japanese Society for Magnetic Resonance in Medicine
record_format MEDLINE/PubMed
spelling pubmed-63267622019-01-11 The Reliability of Reduced Field-of-view DTI for Highly Accurate Quantitative Assessment of Cervical Spinal Cord Tracts Yokohama, Takumi Iwasaki, Motoyuki Oura, Daisuke Furuya, Sho Okuaki, Tomoyuki Magn Reson Med Sci Major Paper PURPOSE: To compare the accuracy of fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values between reduced FOV or so-called zonally oblique multislice (ZOOM) and conventional diffusion tensor imaging (DTI) in the cervical spinal cord. METHODS: Both ZOOM and conventional DTI were performed on 10 healthy volunteers. Intraclass correlation coefficient (ICC) was used to evaluate the reliability of the measurements obtained. Four radiologists evaluated the FA and ADC values at each cervical cord level and classified the visibility by 4 ranks. The geometric distortion ratios of the long axis and short axis were compared between ZOOM and conventional DTI. The imaging parameters were as follows: b-value = 600 s/mm(2); TR = 4500 ms; TE = 81 ms; FOV = 70 × 47 mm(2) / 200 × 200 mm(2); matrix = 80 × 51 / 128 × 126 (ZOOM and conventional DTI, respectively). The region of interest was carefully drawn inside the spinal cord margin to exclude the spinal cord component, without excluding the white matter fiber tracts. RESULTS: The average FA value decreased in both ZOOM and conventional DTI in lower spinal cord levels; in contrast, the ADC value increased in lower spinal cord levels. Zonally oblique multislice DTI was superior to conventional DTI with regard to inter-rater and intra-rater reliability; further, visibility was better and the standard deviation was smaller in ZOOM DTI. On both the long and short axis, the geometric distortion ratio was lower in ZOOM DTI at all cervical spinal cord levels compared with the conventional DTI. There was a significant difference in the distortion ratios of the long and short axis between ZOOM and conventional DTI. CONCLUSION: Conventional DTI is unreliable owing to its susceptibility to the surrounding magnetic field. ZOOM DTI is reliable for performing highly accurate evaluations. Japanese Society for Magnetic Resonance in Medicine 2018-03-23 /pmc/articles/PMC6326762/ /pubmed/29576582 http://dx.doi.org/10.2463/mrms.mp.2017-0078 Text en © 2018 Japanese Society for Magnetic Resonance in Medicine This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Major Paper
Yokohama, Takumi
Iwasaki, Motoyuki
Oura, Daisuke
Furuya, Sho
Okuaki, Tomoyuki
The Reliability of Reduced Field-of-view DTI for Highly Accurate Quantitative Assessment of Cervical Spinal Cord Tracts
title The Reliability of Reduced Field-of-view DTI for Highly Accurate Quantitative Assessment of Cervical Spinal Cord Tracts
title_full The Reliability of Reduced Field-of-view DTI for Highly Accurate Quantitative Assessment of Cervical Spinal Cord Tracts
title_fullStr The Reliability of Reduced Field-of-view DTI for Highly Accurate Quantitative Assessment of Cervical Spinal Cord Tracts
title_full_unstemmed The Reliability of Reduced Field-of-view DTI for Highly Accurate Quantitative Assessment of Cervical Spinal Cord Tracts
title_short The Reliability of Reduced Field-of-view DTI for Highly Accurate Quantitative Assessment of Cervical Spinal Cord Tracts
title_sort reliability of reduced field-of-view dti for highly accurate quantitative assessment of cervical spinal cord tracts
topic Major Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6326762/
https://www.ncbi.nlm.nih.gov/pubmed/29576582
http://dx.doi.org/10.2463/mrms.mp.2017-0078
work_keys_str_mv AT yokohamatakumi thereliabilityofreducedfieldofviewdtiforhighlyaccuratequantitativeassessmentofcervicalspinalcordtracts
AT iwasakimotoyuki thereliabilityofreducedfieldofviewdtiforhighlyaccuratequantitativeassessmentofcervicalspinalcordtracts
AT ouradaisuke thereliabilityofreducedfieldofviewdtiforhighlyaccuratequantitativeassessmentofcervicalspinalcordtracts
AT furuyasho thereliabilityofreducedfieldofviewdtiforhighlyaccuratequantitativeassessmentofcervicalspinalcordtracts
AT okuakitomoyuki thereliabilityofreducedfieldofviewdtiforhighlyaccuratequantitativeassessmentofcervicalspinalcordtracts
AT yokohamatakumi reliabilityofreducedfieldofviewdtiforhighlyaccuratequantitativeassessmentofcervicalspinalcordtracts
AT iwasakimotoyuki reliabilityofreducedfieldofviewdtiforhighlyaccuratequantitativeassessmentofcervicalspinalcordtracts
AT ouradaisuke reliabilityofreducedfieldofviewdtiforhighlyaccuratequantitativeassessmentofcervicalspinalcordtracts
AT furuyasho reliabilityofreducedfieldofviewdtiforhighlyaccuratequantitativeassessmentofcervicalspinalcordtracts
AT okuakitomoyuki reliabilityofreducedfieldofviewdtiforhighlyaccuratequantitativeassessmentofcervicalspinalcordtracts