Cargando…

Increased throughput and ultra-high mass resolution in DESI FT-ICR MS imaging through new-generation external data acquisition system and advanced data processing approaches

Desorption electrospray ionisation-mass spectrometry imaging (DESI-MSI) is a powerful imaging technique for the analysis of complex surfaces. However, the often highly complex nature of biological samples is particularly challenging for MSI approaches, as options to appropriately address molecular c...

Descripción completa

Detalles Bibliográficos
Autores principales: Kooijman, Pieter C., Nagornov, Konstantin O., Kozhinov, Anton N., Kilgour, David P. A., Tsybin, Yury O., Heeren, Ron M. A., Ellis, Shane R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6327097/
https://www.ncbi.nlm.nih.gov/pubmed/30626890
http://dx.doi.org/10.1038/s41598-018-36957-1
_version_ 1783386409086746624
author Kooijman, Pieter C.
Nagornov, Konstantin O.
Kozhinov, Anton N.
Kilgour, David P. A.
Tsybin, Yury O.
Heeren, Ron M. A.
Ellis, Shane R.
author_facet Kooijman, Pieter C.
Nagornov, Konstantin O.
Kozhinov, Anton N.
Kilgour, David P. A.
Tsybin, Yury O.
Heeren, Ron M. A.
Ellis, Shane R.
author_sort Kooijman, Pieter C.
collection PubMed
description Desorption electrospray ionisation-mass spectrometry imaging (DESI-MSI) is a powerful imaging technique for the analysis of complex surfaces. However, the often highly complex nature of biological samples is particularly challenging for MSI approaches, as options to appropriately address molecular complexity are limited. Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) offers superior mass accuracy and mass resolving power, but its moderate throughput inhibits broader application. Here we demonstrate the dramatic gains in mass resolution and/or throughput of DESI-MSI on an FT-ICR MS by developing and implementing a sophisticated data acquisition and data processing pipeline. The presented pipeline integrates, for the first time, parallel ion accumulation and detection, post-processing absorption mode Fourier transform and pixel-by-pixel internal re-calibration. To achieve that, first, we developed and coupled an external high-performance data acquisition system to an FT-ICR MS instrument to record the time-domain signals (transients) in parallel with the instrument’s built-in electronics. The recorded transients were then processed by the in-house developed computationally-efficient data processing and data analysis software. Importantly, the described pipeline is shown to be applicable even to extremely large, up to 1 TB, imaging datasets. Overall, this approach provides improved analytical figures of merits such as: (i) enhanced mass resolution at no cost in experimental time; and (ii) up to 4-fold higher throughput while maintaining a constant mass resolution. Using this approach, we not only demonstrate the record 1 million mass resolution for lipid imaging from brain tissue, but explicitly show such mass resolution is required to resolve the complexity of the lipidome.
format Online
Article
Text
id pubmed-6327097
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-63270972019-01-11 Increased throughput and ultra-high mass resolution in DESI FT-ICR MS imaging through new-generation external data acquisition system and advanced data processing approaches Kooijman, Pieter C. Nagornov, Konstantin O. Kozhinov, Anton N. Kilgour, David P. A. Tsybin, Yury O. Heeren, Ron M. A. Ellis, Shane R. Sci Rep Article Desorption electrospray ionisation-mass spectrometry imaging (DESI-MSI) is a powerful imaging technique for the analysis of complex surfaces. However, the often highly complex nature of biological samples is particularly challenging for MSI approaches, as options to appropriately address molecular complexity are limited. Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) offers superior mass accuracy and mass resolving power, but its moderate throughput inhibits broader application. Here we demonstrate the dramatic gains in mass resolution and/or throughput of DESI-MSI on an FT-ICR MS by developing and implementing a sophisticated data acquisition and data processing pipeline. The presented pipeline integrates, for the first time, parallel ion accumulation and detection, post-processing absorption mode Fourier transform and pixel-by-pixel internal re-calibration. To achieve that, first, we developed and coupled an external high-performance data acquisition system to an FT-ICR MS instrument to record the time-domain signals (transients) in parallel with the instrument’s built-in electronics. The recorded transients were then processed by the in-house developed computationally-efficient data processing and data analysis software. Importantly, the described pipeline is shown to be applicable even to extremely large, up to 1 TB, imaging datasets. Overall, this approach provides improved analytical figures of merits such as: (i) enhanced mass resolution at no cost in experimental time; and (ii) up to 4-fold higher throughput while maintaining a constant mass resolution. Using this approach, we not only demonstrate the record 1 million mass resolution for lipid imaging from brain tissue, but explicitly show such mass resolution is required to resolve the complexity of the lipidome. Nature Publishing Group UK 2019-01-09 /pmc/articles/PMC6327097/ /pubmed/30626890 http://dx.doi.org/10.1038/s41598-018-36957-1 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Kooijman, Pieter C.
Nagornov, Konstantin O.
Kozhinov, Anton N.
Kilgour, David P. A.
Tsybin, Yury O.
Heeren, Ron M. A.
Ellis, Shane R.
Increased throughput and ultra-high mass resolution in DESI FT-ICR MS imaging through new-generation external data acquisition system and advanced data processing approaches
title Increased throughput and ultra-high mass resolution in DESI FT-ICR MS imaging through new-generation external data acquisition system and advanced data processing approaches
title_full Increased throughput and ultra-high mass resolution in DESI FT-ICR MS imaging through new-generation external data acquisition system and advanced data processing approaches
title_fullStr Increased throughput and ultra-high mass resolution in DESI FT-ICR MS imaging through new-generation external data acquisition system and advanced data processing approaches
title_full_unstemmed Increased throughput and ultra-high mass resolution in DESI FT-ICR MS imaging through new-generation external data acquisition system and advanced data processing approaches
title_short Increased throughput and ultra-high mass resolution in DESI FT-ICR MS imaging through new-generation external data acquisition system and advanced data processing approaches
title_sort increased throughput and ultra-high mass resolution in desi ft-icr ms imaging through new-generation external data acquisition system and advanced data processing approaches
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6327097/
https://www.ncbi.nlm.nih.gov/pubmed/30626890
http://dx.doi.org/10.1038/s41598-018-36957-1
work_keys_str_mv AT kooijmanpieterc increasedthroughputandultrahighmassresolutionindesifticrmsimagingthroughnewgenerationexternaldataacquisitionsystemandadvanceddataprocessingapproaches
AT nagornovkonstantino increasedthroughputandultrahighmassresolutionindesifticrmsimagingthroughnewgenerationexternaldataacquisitionsystemandadvanceddataprocessingapproaches
AT kozhinovantonn increasedthroughputandultrahighmassresolutionindesifticrmsimagingthroughnewgenerationexternaldataacquisitionsystemandadvanceddataprocessingapproaches
AT kilgourdavidpa increasedthroughputandultrahighmassresolutionindesifticrmsimagingthroughnewgenerationexternaldataacquisitionsystemandadvanceddataprocessingapproaches
AT tsybinyuryo increasedthroughputandultrahighmassresolutionindesifticrmsimagingthroughnewgenerationexternaldataacquisitionsystemandadvanceddataprocessingapproaches
AT heerenronma increasedthroughputandultrahighmassresolutionindesifticrmsimagingthroughnewgenerationexternaldataacquisitionsystemandadvanceddataprocessingapproaches
AT ellisshaner increasedthroughputandultrahighmassresolutionindesifticrmsimagingthroughnewgenerationexternaldataacquisitionsystemandadvanceddataprocessingapproaches