Cargando…

Correlation between Heart Rate Variability and Bladder Sensations During Filling and Voiding Phase of Urodynamic Study in Patients with Myelopathy

OBJECTIVE: The objective of this study was to correlation between heart rate variability (HRV) and bladder sensations during filling and voiding phase of urodynamic study (UDS) in patients with myelopathy. MATERIALS AND METHODS: Myelopathy patients (traumatic and nontraumatic) within 6 months of ill...

Descripción completa

Detalles Bibliográficos
Autores principales: Gomez, Tenzil, Gupta, Anupam, Rashmi Krishnan, U. K., Chakraborty, Anirban, Sathyaprabha, Talakad Narasappa, Thennarasu, K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6327692/
https://www.ncbi.nlm.nih.gov/pubmed/30692761
http://dx.doi.org/10.4103/aian.AIAN_453_17
_version_ 1783386516722024448
author Gomez, Tenzil
Gupta, Anupam
Rashmi Krishnan, U. K.
Chakraborty, Anirban
Sathyaprabha, Talakad Narasappa
Thennarasu, K.
author_facet Gomez, Tenzil
Gupta, Anupam
Rashmi Krishnan, U. K.
Chakraborty, Anirban
Sathyaprabha, Talakad Narasappa
Thennarasu, K.
author_sort Gomez, Tenzil
collection PubMed
description OBJECTIVE: The objective of this study was to correlation between heart rate variability (HRV) and bladder sensations during filling and voiding phase of urodynamic study (UDS) in patients with myelopathy. MATERIALS AND METHODS: Myelopathy patients (traumatic and nontraumatic) within 6 months of illness were included in the study. Demographic data, etiopathological diagnosis, and urinary complaints were noted. UDS was performed and simultaneous HRV calculated at each event of filling and voiding phase by recording and calculating standard deviation of normal-to-normal (NN) interval (SDNN), root mean square of successive differences, total power (TP), average heart rate, high frequency (HF), low-frequency (LF) ratio, and data analyzed. RESULTS: The study included 30 patients (23 males) with a mean age of 31.2 years (range 18–60 years, standard deviation 11.6). The mean of LF in normalized units showed an increase from 43.6 ± 14.1 at baseline to 48.9 ± 17.4 at strong desire to void (SDV) and at urgency to 44.1 ± 14.5. HF at baseline 40.4 ± 14.1 reduced to 36.4 ± 12.8 at SDV and rose at urgency to 41.2 ± 13.2. LF/HF at baseline was 1.3 ± 0.8, which increased to 1.6 ± 1.1 at SDV and reduced at urgency to 1.2 ± 0.6. Significant change in mean value was seen in TP (P = 0.01) and SDNN (P = 0.009) at first desire to void. Significant positive trend was seen in TP (P = 0.048) and SDNN (P = 0.042) during filling. CONCLUSION: Comparison of HRV measures failed to show significant rise in sympathetic or parasympathetic component in myelopathy patients during UDS and requires more critical evaluation.
format Online
Article
Text
id pubmed-6327692
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-63276922019-01-28 Correlation between Heart Rate Variability and Bladder Sensations During Filling and Voiding Phase of Urodynamic Study in Patients with Myelopathy Gomez, Tenzil Gupta, Anupam Rashmi Krishnan, U. K. Chakraborty, Anirban Sathyaprabha, Talakad Narasappa Thennarasu, K. Ann Indian Acad Neurol Original Article OBJECTIVE: The objective of this study was to correlation between heart rate variability (HRV) and bladder sensations during filling and voiding phase of urodynamic study (UDS) in patients with myelopathy. MATERIALS AND METHODS: Myelopathy patients (traumatic and nontraumatic) within 6 months of illness were included in the study. Demographic data, etiopathological diagnosis, and urinary complaints were noted. UDS was performed and simultaneous HRV calculated at each event of filling and voiding phase by recording and calculating standard deviation of normal-to-normal (NN) interval (SDNN), root mean square of successive differences, total power (TP), average heart rate, high frequency (HF), low-frequency (LF) ratio, and data analyzed. RESULTS: The study included 30 patients (23 males) with a mean age of 31.2 years (range 18–60 years, standard deviation 11.6). The mean of LF in normalized units showed an increase from 43.6 ± 14.1 at baseline to 48.9 ± 17.4 at strong desire to void (SDV) and at urgency to 44.1 ± 14.5. HF at baseline 40.4 ± 14.1 reduced to 36.4 ± 12.8 at SDV and rose at urgency to 41.2 ± 13.2. LF/HF at baseline was 1.3 ± 0.8, which increased to 1.6 ± 1.1 at SDV and reduced at urgency to 1.2 ± 0.6. Significant change in mean value was seen in TP (P = 0.01) and SDNN (P = 0.009) at first desire to void. Significant positive trend was seen in TP (P = 0.048) and SDNN (P = 0.042) during filling. CONCLUSION: Comparison of HRV measures failed to show significant rise in sympathetic or parasympathetic component in myelopathy patients during UDS and requires more critical evaluation. Medknow Publications & Media Pvt Ltd 2019 /pmc/articles/PMC6327692/ /pubmed/30692761 http://dx.doi.org/10.4103/aian.AIAN_453_17 Text en Copyright: © 2006 - 2018 Annals of Indian Academy of Neurology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Gomez, Tenzil
Gupta, Anupam
Rashmi Krishnan, U. K.
Chakraborty, Anirban
Sathyaprabha, Talakad Narasappa
Thennarasu, K.
Correlation between Heart Rate Variability and Bladder Sensations During Filling and Voiding Phase of Urodynamic Study in Patients with Myelopathy
title Correlation between Heart Rate Variability and Bladder Sensations During Filling and Voiding Phase of Urodynamic Study in Patients with Myelopathy
title_full Correlation between Heart Rate Variability and Bladder Sensations During Filling and Voiding Phase of Urodynamic Study in Patients with Myelopathy
title_fullStr Correlation between Heart Rate Variability and Bladder Sensations During Filling and Voiding Phase of Urodynamic Study in Patients with Myelopathy
title_full_unstemmed Correlation between Heart Rate Variability and Bladder Sensations During Filling and Voiding Phase of Urodynamic Study in Patients with Myelopathy
title_short Correlation between Heart Rate Variability and Bladder Sensations During Filling and Voiding Phase of Urodynamic Study in Patients with Myelopathy
title_sort correlation between heart rate variability and bladder sensations during filling and voiding phase of urodynamic study in patients with myelopathy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6327692/
https://www.ncbi.nlm.nih.gov/pubmed/30692761
http://dx.doi.org/10.4103/aian.AIAN_453_17
work_keys_str_mv AT gomeztenzil correlationbetweenheartratevariabilityandbladdersensationsduringfillingandvoidingphaseofurodynamicstudyinpatientswithmyelopathy
AT guptaanupam correlationbetweenheartratevariabilityandbladdersensationsduringfillingandvoidingphaseofurodynamicstudyinpatientswithmyelopathy
AT rashmikrishnanuk correlationbetweenheartratevariabilityandbladdersensationsduringfillingandvoidingphaseofurodynamicstudyinpatientswithmyelopathy
AT chakrabortyanirban correlationbetweenheartratevariabilityandbladdersensationsduringfillingandvoidingphaseofurodynamicstudyinpatientswithmyelopathy
AT sathyaprabhatalakadnarasappa correlationbetweenheartratevariabilityandbladdersensationsduringfillingandvoidingphaseofurodynamicstudyinpatientswithmyelopathy
AT thennarasuk correlationbetweenheartratevariabilityandbladdersensationsduringfillingandvoidingphaseofurodynamicstudyinpatientswithmyelopathy