Cargando…
Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation
BACKGROUND: The aim of this study was to compare the metrics of volume computed tomography index (CTDI(vol)) and size-specific dose estimate (SSDE), and quantity the differences in head CT examinations of adult patients. MATERIAL/METHODS: A total of 157 patients underwent head CT examination were en...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6327780/ https://www.ncbi.nlm.nih.gov/pubmed/30604739 http://dx.doi.org/10.12659/MSM.913927 |
_version_ | 1783386534049742848 |
---|---|
author | Xu, Jian He, Xiaolong Xiao, Huawei Xu, Jianguo |
author_facet | Xu, Jian He, Xiaolong Xiao, Huawei Xu, Jianguo |
author_sort | Xu, Jian |
collection | PubMed |
description | BACKGROUND: The aim of this study was to compare the metrics of volume computed tomography index (CTDI(vol)) and size-specific dose estimate (SSDE), and quantity the differences in head CT examinations of adult patients. MATERIAL/METHODS: A total of 157 patients underwent head CT examination were enrolled in this retrospective study. Pearson correlation analysis and linear regression correlation analysis were performed to observe the correlation between the dose metrics of CTDI(vol) and SSDEaver versus tube current product (mAs) and water equivalent diameter (WED). Correlated factors of CTDI(vol) and SSDEaver were analyzed by multivariate linear stepwise regression analysis. RESULTS: A sum of 4239 data settings were measured: slices with WED >16 cm was 71.05%, and the slices with f <1 was 72.64%. The average value of the absolute difference between WED and the diameter of AAPM head phantom was 2.24±1.42 cm. Statistically significant difference was found between the values of CTDI(vol) and SSDEaver (P=0.000). The dispersion degree of the CTDI(vol) values was greater than that of SSDEaver. Strong positive correlation was shown between CTDI(vol) and mAs (P=0.000), as well as CTDI(vol) and WED (P=0.000). Strong positive correlation was shown between SSDEaver and mAs (P=0.000), and moderate correlation for SSDEaver and WED (P=0.000). Both the metrics of mAs and WED were included in the multivariate linear stepwise regression equation to observe the effect of related factors on the value of SSDEaver. CONCLUSIONS: SSDEaver with better representative can reproduce the radiation dosage of the specific adult patients in head CT examination. |
format | Online Article Text |
id | pubmed-6327780 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-63277802019-01-28 Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation Xu, Jian He, Xiaolong Xiao, Huawei Xu, Jianguo Med Sci Monit Clinical Research BACKGROUND: The aim of this study was to compare the metrics of volume computed tomography index (CTDI(vol)) and size-specific dose estimate (SSDE), and quantity the differences in head CT examinations of adult patients. MATERIAL/METHODS: A total of 157 patients underwent head CT examination were enrolled in this retrospective study. Pearson correlation analysis and linear regression correlation analysis were performed to observe the correlation between the dose metrics of CTDI(vol) and SSDEaver versus tube current product (mAs) and water equivalent diameter (WED). Correlated factors of CTDI(vol) and SSDEaver were analyzed by multivariate linear stepwise regression analysis. RESULTS: A sum of 4239 data settings were measured: slices with WED >16 cm was 71.05%, and the slices with f <1 was 72.64%. The average value of the absolute difference between WED and the diameter of AAPM head phantom was 2.24±1.42 cm. Statistically significant difference was found between the values of CTDI(vol) and SSDEaver (P=0.000). The dispersion degree of the CTDI(vol) values was greater than that of SSDEaver. Strong positive correlation was shown between CTDI(vol) and mAs (P=0.000), as well as CTDI(vol) and WED (P=0.000). Strong positive correlation was shown between SSDEaver and mAs (P=0.000), and moderate correlation for SSDEaver and WED (P=0.000). Both the metrics of mAs and WED were included in the multivariate linear stepwise regression equation to observe the effect of related factors on the value of SSDEaver. CONCLUSIONS: SSDEaver with better representative can reproduce the radiation dosage of the specific adult patients in head CT examination. International Scientific Literature, Inc. 2019-01-03 /pmc/articles/PMC6327780/ /pubmed/30604739 http://dx.doi.org/10.12659/MSM.913927 Text en © Med Sci Monit, 2019 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) ) |
spellingShingle | Clinical Research Xu, Jian He, Xiaolong Xiao, Huawei Xu, Jianguo Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation |
title | Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation |
title_full | Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation |
title_fullStr | Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation |
title_full_unstemmed | Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation |
title_short | Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation |
title_sort | comparative study of volume computed tomography dose index and size-specific dose estimate head in computed tomography examination for adult patients based on the mode of automatic tube current modulation |
topic | Clinical Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6327780/ https://www.ncbi.nlm.nih.gov/pubmed/30604739 http://dx.doi.org/10.12659/MSM.913927 |
work_keys_str_mv | AT xujian comparativestudyofvolumecomputedtomographydoseindexandsizespecificdoseestimateheadincomputedtomographyexaminationforadultpatientsbasedonthemodeofautomatictubecurrentmodulation AT hexiaolong comparativestudyofvolumecomputedtomographydoseindexandsizespecificdoseestimateheadincomputedtomographyexaminationforadultpatientsbasedonthemodeofautomatictubecurrentmodulation AT xiaohuawei comparativestudyofvolumecomputedtomographydoseindexandsizespecificdoseestimateheadincomputedtomographyexaminationforadultpatientsbasedonthemodeofautomatictubecurrentmodulation AT xujianguo comparativestudyofvolumecomputedtomographydoseindexandsizespecificdoseestimateheadincomputedtomographyexaminationforadultpatientsbasedonthemodeofautomatictubecurrentmodulation |