Cargando…

Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation

BACKGROUND: The aim of this study was to compare the metrics of volume computed tomography index (CTDI(vol)) and size-specific dose estimate (SSDE), and quantity the differences in head CT examinations of adult patients. MATERIAL/METHODS: A total of 157 patients underwent head CT examination were en...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Jian, He, Xiaolong, Xiao, Huawei, Xu, Jianguo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6327780/
https://www.ncbi.nlm.nih.gov/pubmed/30604739
http://dx.doi.org/10.12659/MSM.913927
_version_ 1783386534049742848
author Xu, Jian
He, Xiaolong
Xiao, Huawei
Xu, Jianguo
author_facet Xu, Jian
He, Xiaolong
Xiao, Huawei
Xu, Jianguo
author_sort Xu, Jian
collection PubMed
description BACKGROUND: The aim of this study was to compare the metrics of volume computed tomography index (CTDI(vol)) and size-specific dose estimate (SSDE), and quantity the differences in head CT examinations of adult patients. MATERIAL/METHODS: A total of 157 patients underwent head CT examination were enrolled in this retrospective study. Pearson correlation analysis and linear regression correlation analysis were performed to observe the correlation between the dose metrics of CTDI(vol) and SSDEaver versus tube current product (mAs) and water equivalent diameter (WED). Correlated factors of CTDI(vol) and SSDEaver were analyzed by multivariate linear stepwise regression analysis. RESULTS: A sum of 4239 data settings were measured: slices with WED >16 cm was 71.05%, and the slices with f <1 was 72.64%. The average value of the absolute difference between WED and the diameter of AAPM head phantom was 2.24±1.42 cm. Statistically significant difference was found between the values of CTDI(vol) and SSDEaver (P=0.000). The dispersion degree of the CTDI(vol) values was greater than that of SSDEaver. Strong positive correlation was shown between CTDI(vol) and mAs (P=0.000), as well as CTDI(vol) and WED (P=0.000). Strong positive correlation was shown between SSDEaver and mAs (P=0.000), and moderate correlation for SSDEaver and WED (P=0.000). Both the metrics of mAs and WED were included in the multivariate linear stepwise regression equation to observe the effect of related factors on the value of SSDEaver. CONCLUSIONS: SSDEaver with better representative can reproduce the radiation dosage of the specific adult patients in head CT examination.
format Online
Article
Text
id pubmed-6327780
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-63277802019-01-28 Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation Xu, Jian He, Xiaolong Xiao, Huawei Xu, Jianguo Med Sci Monit Clinical Research BACKGROUND: The aim of this study was to compare the metrics of volume computed tomography index (CTDI(vol)) and size-specific dose estimate (SSDE), and quantity the differences in head CT examinations of adult patients. MATERIAL/METHODS: A total of 157 patients underwent head CT examination were enrolled in this retrospective study. Pearson correlation analysis and linear regression correlation analysis were performed to observe the correlation between the dose metrics of CTDI(vol) and SSDEaver versus tube current product (mAs) and water equivalent diameter (WED). Correlated factors of CTDI(vol) and SSDEaver were analyzed by multivariate linear stepwise regression analysis. RESULTS: A sum of 4239 data settings were measured: slices with WED >16 cm was 71.05%, and the slices with f <1 was 72.64%. The average value of the absolute difference between WED and the diameter of AAPM head phantom was 2.24±1.42 cm. Statistically significant difference was found between the values of CTDI(vol) and SSDEaver (P=0.000). The dispersion degree of the CTDI(vol) values was greater than that of SSDEaver. Strong positive correlation was shown between CTDI(vol) and mAs (P=0.000), as well as CTDI(vol) and WED (P=0.000). Strong positive correlation was shown between SSDEaver and mAs (P=0.000), and moderate correlation for SSDEaver and WED (P=0.000). Both the metrics of mAs and WED were included in the multivariate linear stepwise regression equation to observe the effect of related factors on the value of SSDEaver. CONCLUSIONS: SSDEaver with better representative can reproduce the radiation dosage of the specific adult patients in head CT examination. International Scientific Literature, Inc. 2019-01-03 /pmc/articles/PMC6327780/ /pubmed/30604739 http://dx.doi.org/10.12659/MSM.913927 Text en © Med Sci Monit, 2019 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Xu, Jian
He, Xiaolong
Xiao, Huawei
Xu, Jianguo
Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation
title Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation
title_full Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation
title_fullStr Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation
title_full_unstemmed Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation
title_short Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation
title_sort comparative study of volume computed tomography dose index and size-specific dose estimate head in computed tomography examination for adult patients based on the mode of automatic tube current modulation
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6327780/
https://www.ncbi.nlm.nih.gov/pubmed/30604739
http://dx.doi.org/10.12659/MSM.913927
work_keys_str_mv AT xujian comparativestudyofvolumecomputedtomographydoseindexandsizespecificdoseestimateheadincomputedtomographyexaminationforadultpatientsbasedonthemodeofautomatictubecurrentmodulation
AT hexiaolong comparativestudyofvolumecomputedtomographydoseindexandsizespecificdoseestimateheadincomputedtomographyexaminationforadultpatientsbasedonthemodeofautomatictubecurrentmodulation
AT xiaohuawei comparativestudyofvolumecomputedtomographydoseindexandsizespecificdoseestimateheadincomputedtomographyexaminationforadultpatientsbasedonthemodeofautomatictubecurrentmodulation
AT xujianguo comparativestudyofvolumecomputedtomographydoseindexandsizespecificdoseestimateheadincomputedtomographyexaminationforadultpatientsbasedonthemodeofautomatictubecurrentmodulation