Cargando…

Prospective evaluation of a novel silicone corneal shield after PRK: 6-month efficacy, safety, and predictability outcomes

PURPOSE: The aim of this study was to report the 1-week and 6-month refractive outcomes of eyes treated with a novel silicone corneal shield designed to improve visual recovery after photorefractive keratectomy (PRK). PATIENTS AND METHODS: This prospective, observational clinical trial recruited 45...

Descripción completa

Detalles Bibliográficos
Autores principales: Sáles, Christopher S, Manche, Edward E
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6327892/
https://www.ncbi.nlm.nih.gov/pubmed/30662255
http://dx.doi.org/10.2147/OPTH.S183120
_version_ 1783386561299087360
author Sáles, Christopher S
Manche, Edward E
author_facet Sáles, Christopher S
Manche, Edward E
author_sort Sáles, Christopher S
collection PubMed
description PURPOSE: The aim of this study was to report the 1-week and 6-month refractive outcomes of eyes treated with a novel silicone corneal shield designed to improve visual recovery after photorefractive keratectomy (PRK). PATIENTS AND METHODS: This prospective, observational clinical trial recruited 45 myopic eyes with or without astigmatism at a university eye clinic to undergo wavefront-guided PRK followed by application of an investigational silicone corneal shield that was removed on postoperative day 4. The primary outcome measures were efficacy, predictability, and safety at the 6-month visit. The secondary end points included short-term uncorrected distance visual acuity (UDVA) and pain. RESULTS: No adverse outcomes occurred using the device. At 6 months, 79.5% of eyes achieved UDVA >20/20, 94.9% achieved ≥20/25, and 97.4% achieved ≥20/40. Also, 2.6% lost one line of corrected distance visual acuity and none lost two lines; 71.8% and 97.4% measured within ±0.25 and ±0.50 D of emmetropia, respectively. During the first week, preoperative UDVA improved from 1.34 logarithm of the minimum angle of resolution (logMAR; <20/400 Snellen) to 0.14 logMAR (>20/30) on postoperative day 1 (P<0.0001) and remained stable on days 2–3 (all P>0.05). After removal of the shield on day 4, UDVA declined by two lines before rebounding to 0.16 logMAR (>20/30) on day 7 (both P<0.001). Subjective metrics of pain all peaked between days 2 and 3 before declining. CONCLUSION: The investigational silicone corneal shield is safe and effective when used after PRK and may aid early visual recovery and patient comfort, but comparative studies are needed to validate these preliminary findings. PRECIS: One-week and 6-month refractive outcomes of a novel silicone corneal shield used after PRK show that the device is not only safe and effective but may also speed visual recovery.
format Online
Article
Text
id pubmed-6327892
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-63278922019-01-18 Prospective evaluation of a novel silicone corneal shield after PRK: 6-month efficacy, safety, and predictability outcomes Sáles, Christopher S Manche, Edward E Clin Ophthalmol Original Research PURPOSE: The aim of this study was to report the 1-week and 6-month refractive outcomes of eyes treated with a novel silicone corneal shield designed to improve visual recovery after photorefractive keratectomy (PRK). PATIENTS AND METHODS: This prospective, observational clinical trial recruited 45 myopic eyes with or without astigmatism at a university eye clinic to undergo wavefront-guided PRK followed by application of an investigational silicone corneal shield that was removed on postoperative day 4. The primary outcome measures were efficacy, predictability, and safety at the 6-month visit. The secondary end points included short-term uncorrected distance visual acuity (UDVA) and pain. RESULTS: No adverse outcomes occurred using the device. At 6 months, 79.5% of eyes achieved UDVA >20/20, 94.9% achieved ≥20/25, and 97.4% achieved ≥20/40. Also, 2.6% lost one line of corrected distance visual acuity and none lost two lines; 71.8% and 97.4% measured within ±0.25 and ±0.50 D of emmetropia, respectively. During the first week, preoperative UDVA improved from 1.34 logarithm of the minimum angle of resolution (logMAR; <20/400 Snellen) to 0.14 logMAR (>20/30) on postoperative day 1 (P<0.0001) and remained stable on days 2–3 (all P>0.05). After removal of the shield on day 4, UDVA declined by two lines before rebounding to 0.16 logMAR (>20/30) on day 7 (both P<0.001). Subjective metrics of pain all peaked between days 2 and 3 before declining. CONCLUSION: The investigational silicone corneal shield is safe and effective when used after PRK and may aid early visual recovery and patient comfort, but comparative studies are needed to validate these preliminary findings. PRECIS: One-week and 6-month refractive outcomes of a novel silicone corneal shield used after PRK show that the device is not only safe and effective but may also speed visual recovery. Dove Medical Press 2019-01-07 /pmc/articles/PMC6327892/ /pubmed/30662255 http://dx.doi.org/10.2147/OPTH.S183120 Text en © 2019 Sáles and Manche. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Sáles, Christopher S
Manche, Edward E
Prospective evaluation of a novel silicone corneal shield after PRK: 6-month efficacy, safety, and predictability outcomes
title Prospective evaluation of a novel silicone corneal shield after PRK: 6-month efficacy, safety, and predictability outcomes
title_full Prospective evaluation of a novel silicone corneal shield after PRK: 6-month efficacy, safety, and predictability outcomes
title_fullStr Prospective evaluation of a novel silicone corneal shield after PRK: 6-month efficacy, safety, and predictability outcomes
title_full_unstemmed Prospective evaluation of a novel silicone corneal shield after PRK: 6-month efficacy, safety, and predictability outcomes
title_short Prospective evaluation of a novel silicone corneal shield after PRK: 6-month efficacy, safety, and predictability outcomes
title_sort prospective evaluation of a novel silicone corneal shield after prk: 6-month efficacy, safety, and predictability outcomes
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6327892/
https://www.ncbi.nlm.nih.gov/pubmed/30662255
http://dx.doi.org/10.2147/OPTH.S183120
work_keys_str_mv AT saleschristophers prospectiveevaluationofanovelsiliconecornealshieldafterprk6monthefficacysafetyandpredictabilityoutcomes
AT mancheedwarde prospectiveevaluationofanovelsiliconecornealshieldafterprk6monthefficacysafetyandpredictabilityoutcomes