Cargando…
Electrical fields induced inside the rat brain with skin, skull, and dural placements of the current injection electrode
Transcranial electrical stimulation (tES) is rapidly becoming an indispensable clinical tool with its different forms. Animal data are crucially needed for better understanding of the underlying mechanisms of tES. For reproducibility of results in animal experiments, the electric fields (E-Fields) i...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6328113/ https://www.ncbi.nlm.nih.gov/pubmed/30629578 http://dx.doi.org/10.1371/journal.pone.0203727 |
_version_ | 1783386593551187968 |
---|---|
author | Asan, Ahmet S. Gok, Sinan Sahin, Mesut |
author_facet | Asan, Ahmet S. Gok, Sinan Sahin, Mesut |
author_sort | Asan, Ahmet S. |
collection | PubMed |
description | Transcranial electrical stimulation (tES) is rapidly becoming an indispensable clinical tool with its different forms. Animal data are crucially needed for better understanding of the underlying mechanisms of tES. For reproducibility of results in animal experiments, the electric fields (E-Fields) inside the brain parenchyma induced by the injected currents need to be predicted accurately. In this study, we measured the electrical fields in the rat brain perpendicular to the brain surface, i.e. vertical electric field (VE-field), when the stimulation electrode was placed over the skin, skull, or dura mater through a craniotomy hole. The E-field attenuation through the skin was a few times larger than that of the skull and the presence of skin substantially reduced the VE-field peak at the cortical surface near the electrode. The VE-field declined much quicker in the gray matter underneath the pial surface than it did in the white matter, and thus the large VE-fields were contained mostly in the gray matter. The transition at the gray/white matter border caused a significant peak in the VE-field, as well as at other local inhomogeneties. A conductivity value of 0.57 S/m is predicted as a global value for the whole brain by matching our VE-field measurements to the field profile given by analytical equations for volume conductors. Finally, insertion of the current return electrode into the shoulder, submandibular, and hind leg muscles had virtually no effects on the measured E-field amplitudes in the cortex underneath the epidural electrodes. |
format | Online Article Text |
id | pubmed-6328113 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-63281132019-02-01 Electrical fields induced inside the rat brain with skin, skull, and dural placements of the current injection electrode Asan, Ahmet S. Gok, Sinan Sahin, Mesut PLoS One Research Article Transcranial electrical stimulation (tES) is rapidly becoming an indispensable clinical tool with its different forms. Animal data are crucially needed for better understanding of the underlying mechanisms of tES. For reproducibility of results in animal experiments, the electric fields (E-Fields) inside the brain parenchyma induced by the injected currents need to be predicted accurately. In this study, we measured the electrical fields in the rat brain perpendicular to the brain surface, i.e. vertical electric field (VE-field), when the stimulation electrode was placed over the skin, skull, or dura mater through a craniotomy hole. The E-field attenuation through the skin was a few times larger than that of the skull and the presence of skin substantially reduced the VE-field peak at the cortical surface near the electrode. The VE-field declined much quicker in the gray matter underneath the pial surface than it did in the white matter, and thus the large VE-fields were contained mostly in the gray matter. The transition at the gray/white matter border caused a significant peak in the VE-field, as well as at other local inhomogeneties. A conductivity value of 0.57 S/m is predicted as a global value for the whole brain by matching our VE-field measurements to the field profile given by analytical equations for volume conductors. Finally, insertion of the current return electrode into the shoulder, submandibular, and hind leg muscles had virtually no effects on the measured E-field amplitudes in the cortex underneath the epidural electrodes. Public Library of Science 2019-01-10 /pmc/articles/PMC6328113/ /pubmed/30629578 http://dx.doi.org/10.1371/journal.pone.0203727 Text en © 2019 Asan et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Asan, Ahmet S. Gok, Sinan Sahin, Mesut Electrical fields induced inside the rat brain with skin, skull, and dural placements of the current injection electrode |
title | Electrical fields induced inside the rat brain with skin, skull, and dural placements of the current injection electrode |
title_full | Electrical fields induced inside the rat brain with skin, skull, and dural placements of the current injection electrode |
title_fullStr | Electrical fields induced inside the rat brain with skin, skull, and dural placements of the current injection electrode |
title_full_unstemmed | Electrical fields induced inside the rat brain with skin, skull, and dural placements of the current injection electrode |
title_short | Electrical fields induced inside the rat brain with skin, skull, and dural placements of the current injection electrode |
title_sort | electrical fields induced inside the rat brain with skin, skull, and dural placements of the current injection electrode |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6328113/ https://www.ncbi.nlm.nih.gov/pubmed/30629578 http://dx.doi.org/10.1371/journal.pone.0203727 |
work_keys_str_mv | AT asanahmets electricalfieldsinducedinsidetheratbrainwithskinskullandduralplacementsofthecurrentinjectionelectrode AT goksinan electricalfieldsinducedinsidetheratbrainwithskinskullandduralplacementsofthecurrentinjectionelectrode AT sahinmesut electricalfieldsinducedinsidetheratbrainwithskinskullandduralplacementsofthecurrentinjectionelectrode |