Cargando…

Calibrated cardiac output monitoring versus standard care for fluid management in the shocked ICU patient: a pilot randomised controlled trial

BACKGROUND: Despite the evidence for calibrated cardiac monitored devices to determine fluid responsiveness, there is minimal evidence that the use of cardiac output monitor devices leads to an overall change in IV fluid use. We sought to investigate the feasibility of performing a randomised contro...

Descripción completa

Detalles Bibliográficos
Autores principales: Scully, Timothy G., Grealy, Robert, McLean, Anthony S., Orde, Sam R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6329049/
https://www.ncbi.nlm.nih.gov/pubmed/30656058
http://dx.doi.org/10.1186/s40560-018-0356-y
_version_ 1783386757325127680
author Scully, Timothy G.
Grealy, Robert
McLean, Anthony S.
Orde, Sam R.
author_facet Scully, Timothy G.
Grealy, Robert
McLean, Anthony S.
Orde, Sam R.
author_sort Scully, Timothy G.
collection PubMed
description BACKGROUND: Despite the evidence for calibrated cardiac monitored devices to determine fluid responsiveness, there is minimal evidence that the use of cardiac output monitor devices leads to an overall change in IV fluid use. We sought to investigate the feasibility of performing a randomised controlled study using calibrated cardiac output monitoring devices in shocked ICU patients and whether the use of these devices led to a difference in total volume of IV fluid administered. METHODS: We performed a single-centre non-blinded randomised controlled study which included patients who met the clinical criteria for shock on admission to ICU. Patients were divided into two groups (cardiac output monitors or standard) by block randomisation. Patients allocated to the cardiac output monitor all received EV1000 with Volume View sets. Daily intravenous fluid administration and cumulative fluid balance was recorded for 3 days. The primary outcome assessed was the difference in daily intravenous fluid administration and cumulative fluid balance at 72 h between the two groups. We also assessed how often the clinicians used the cardiac monitor to guide fluid therapy and the different reasoning for initiating further intravenous fluids. RESULTS: Eighty patients were randomised and 37 received calibrated cardiac output monitors. We found no adverse outcomes in the use of calibrated cardiac output monitoring devices and that was feasible to perform a randomised controlled trial. There was no significant difference between the standard care group vs the cardiac monitoring group for cumulative fluid balance (2503 ± 3764 ml vs 2458 ± 3560 ml, p = 0.96). There was no significant difference between the groups for daily intravenous fluid administration on days 1, 2 or 3. In the cardiac monitored group, only 43% of the time was the EV1000 output incorporated into the decision to give further intravenous fluids. CONCLUSION: It is feasible to perform a randomised controlled trial using calibrated cardiac output monitoring devices. In addition, there was no trend to suggest that the use of a cardiac monitors leads to lower IV fluid use in the shocked patient. Further trials will require study designs to optimise the use of a cardiac output monitor to determine the utility of these devices in the shocked patient. TRIAL REGISTRATION: ANZCTR, ACTRN12618001373268. Registered 15 August 2018—retrospectively registered. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s40560-018-0356-y) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6329049
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-63290492019-01-17 Calibrated cardiac output monitoring versus standard care for fluid management in the shocked ICU patient: a pilot randomised controlled trial Scully, Timothy G. Grealy, Robert McLean, Anthony S. Orde, Sam R. J Intensive Care Research BACKGROUND: Despite the evidence for calibrated cardiac monitored devices to determine fluid responsiveness, there is minimal evidence that the use of cardiac output monitor devices leads to an overall change in IV fluid use. We sought to investigate the feasibility of performing a randomised controlled study using calibrated cardiac output monitoring devices in shocked ICU patients and whether the use of these devices led to a difference in total volume of IV fluid administered. METHODS: We performed a single-centre non-blinded randomised controlled study which included patients who met the clinical criteria for shock on admission to ICU. Patients were divided into two groups (cardiac output monitors or standard) by block randomisation. Patients allocated to the cardiac output monitor all received EV1000 with Volume View sets. Daily intravenous fluid administration and cumulative fluid balance was recorded for 3 days. The primary outcome assessed was the difference in daily intravenous fluid administration and cumulative fluid balance at 72 h between the two groups. We also assessed how often the clinicians used the cardiac monitor to guide fluid therapy and the different reasoning for initiating further intravenous fluids. RESULTS: Eighty patients were randomised and 37 received calibrated cardiac output monitors. We found no adverse outcomes in the use of calibrated cardiac output monitoring devices and that was feasible to perform a randomised controlled trial. There was no significant difference between the standard care group vs the cardiac monitoring group for cumulative fluid balance (2503 ± 3764 ml vs 2458 ± 3560 ml, p = 0.96). There was no significant difference between the groups for daily intravenous fluid administration on days 1, 2 or 3. In the cardiac monitored group, only 43% of the time was the EV1000 output incorporated into the decision to give further intravenous fluids. CONCLUSION: It is feasible to perform a randomised controlled trial using calibrated cardiac output monitoring devices. In addition, there was no trend to suggest that the use of a cardiac monitors leads to lower IV fluid use in the shocked patient. Further trials will require study designs to optimise the use of a cardiac output monitor to determine the utility of these devices in the shocked patient. TRIAL REGISTRATION: ANZCTR, ACTRN12618001373268. Registered 15 August 2018—retrospectively registered. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s40560-018-0356-y) contains supplementary material, which is available to authorized users. BioMed Central 2019-01-10 /pmc/articles/PMC6329049/ /pubmed/30656058 http://dx.doi.org/10.1186/s40560-018-0356-y Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Scully, Timothy G.
Grealy, Robert
McLean, Anthony S.
Orde, Sam R.
Calibrated cardiac output monitoring versus standard care for fluid management in the shocked ICU patient: a pilot randomised controlled trial
title Calibrated cardiac output monitoring versus standard care for fluid management in the shocked ICU patient: a pilot randomised controlled trial
title_full Calibrated cardiac output monitoring versus standard care for fluid management in the shocked ICU patient: a pilot randomised controlled trial
title_fullStr Calibrated cardiac output monitoring versus standard care for fluid management in the shocked ICU patient: a pilot randomised controlled trial
title_full_unstemmed Calibrated cardiac output monitoring versus standard care for fluid management in the shocked ICU patient: a pilot randomised controlled trial
title_short Calibrated cardiac output monitoring versus standard care for fluid management in the shocked ICU patient: a pilot randomised controlled trial
title_sort calibrated cardiac output monitoring versus standard care for fluid management in the shocked icu patient: a pilot randomised controlled trial
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6329049/
https://www.ncbi.nlm.nih.gov/pubmed/30656058
http://dx.doi.org/10.1186/s40560-018-0356-y
work_keys_str_mv AT scullytimothyg calibratedcardiacoutputmonitoringversusstandardcareforfluidmanagementintheshockedicupatientapilotrandomisedcontrolledtrial
AT grealyrobert calibratedcardiacoutputmonitoringversusstandardcareforfluidmanagementintheshockedicupatientapilotrandomisedcontrolledtrial
AT mcleananthonys calibratedcardiacoutputmonitoringversusstandardcareforfluidmanagementintheshockedicupatientapilotrandomisedcontrolledtrial
AT ordesamr calibratedcardiacoutputmonitoringversusstandardcareforfluidmanagementintheshockedicupatientapilotrandomisedcontrolledtrial