Cargando…

A Novel Non-invasive Technique of Measuring Bilirubin Levels Using BiliCapture

OBJECTIVES: In preterm infants, hyperbilirubinemia is common and can impair the central nervous system. The tests available for measuring bilirubin is to collect blood from heel pricking and occasionally taking blood samples from inserted cannulas, which is painful. Therefore, there is a need to dev...

Descripción completa

Detalles Bibliográficos
Autores principales: Rizvi, Moattar Raza, Alaskar, Farah Mansoor, Albaradie, Raid Saleem, Rizvi, Noor Fatima, Al-Abdulwahab, Khaled
Formato: Online Artículo Texto
Lenguaje:English
Publicado: OMJ 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6330178/
https://www.ncbi.nlm.nih.gov/pubmed/30671181
http://dx.doi.org/10.5001/omj.2019.05
_version_ 1783386925664567296
author Rizvi, Moattar Raza
Alaskar, Farah Mansoor
Albaradie, Raid Saleem
Rizvi, Noor Fatima
Al-Abdulwahab, Khaled
author_facet Rizvi, Moattar Raza
Alaskar, Farah Mansoor
Albaradie, Raid Saleem
Rizvi, Noor Fatima
Al-Abdulwahab, Khaled
author_sort Rizvi, Moattar Raza
collection PubMed
description OBJECTIVES: In preterm infants, hyperbilirubinemia is common and can impair the central nervous system. The tests available for measuring bilirubin is to collect blood from heel pricking and occasionally taking blood samples from inserted cannulas, which is painful. Therefore, there is a need to develop a non-invasive device to detect bilirubin levels in newborns and interpret the severity of jaundice. METHODS: We conducted a cross-sectional study of 100 neonates. Patient data was collected between June 2015 and December 2016 from King Khalid Hospital at Al-Majma’ah, Saudi Arabia, and Alpine Hospital, Gurgaon, India. The mean gestational age of neonates was 39.0 weeks. Total bilirubin was measured using a transcutaneous bilirubinometer on the forehead and obtaining optical imaging through scanning of conjunctiva of eyes, also referred to as BiliChek and BiliCapture, respectively. Later the blood samples were obtained from these patients and tested in the laboratory to determine total serum bilirubin (TSB) levels. RESULTS: The concentration of bilirubin as measured from serum, BiliChek, and BiliCapture were 10.7±2.0, 11.6±2.7, and 13.1±2.3 mg/dL, respectively. Correlation was high between TSB and BiliChek (r(2) = 0.88) and between TSB and BiliCapture (r(2) = 0.73). The Bland-Altman plots showed good agreement when comparing bilirubin values for both BiliChek and BiliCapture devices. Bilirubin measurement was further checked for the sensitivity and specificity and was 88.0% and 76.0% using BiliChek and 92.0% and 75.6% using BiliCapture, respectively. CONCLUSIONS: The optical imaging of conjunctiva for bilirubin assay is a safe alternative to a laboratory bilirubin assay and transcutaneous bilirubinometer BiliChek.
format Online
Article
Text
id pubmed-6330178
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher OMJ
record_format MEDLINE/PubMed
spelling pubmed-63301782019-01-22 A Novel Non-invasive Technique of Measuring Bilirubin Levels Using BiliCapture Rizvi, Moattar Raza Alaskar, Farah Mansoor Albaradie, Raid Saleem Rizvi, Noor Fatima Al-Abdulwahab, Khaled Oman Med J Original Article OBJECTIVES: In preterm infants, hyperbilirubinemia is common and can impair the central nervous system. The tests available for measuring bilirubin is to collect blood from heel pricking and occasionally taking blood samples from inserted cannulas, which is painful. Therefore, there is a need to develop a non-invasive device to detect bilirubin levels in newborns and interpret the severity of jaundice. METHODS: We conducted a cross-sectional study of 100 neonates. Patient data was collected between June 2015 and December 2016 from King Khalid Hospital at Al-Majma’ah, Saudi Arabia, and Alpine Hospital, Gurgaon, India. The mean gestational age of neonates was 39.0 weeks. Total bilirubin was measured using a transcutaneous bilirubinometer on the forehead and obtaining optical imaging through scanning of conjunctiva of eyes, also referred to as BiliChek and BiliCapture, respectively. Later the blood samples were obtained from these patients and tested in the laboratory to determine total serum bilirubin (TSB) levels. RESULTS: The concentration of bilirubin as measured from serum, BiliChek, and BiliCapture were 10.7±2.0, 11.6±2.7, and 13.1±2.3 mg/dL, respectively. Correlation was high between TSB and BiliChek (r(2) = 0.88) and between TSB and BiliCapture (r(2) = 0.73). The Bland-Altman plots showed good agreement when comparing bilirubin values for both BiliChek and BiliCapture devices. Bilirubin measurement was further checked for the sensitivity and specificity and was 88.0% and 76.0% using BiliChek and 92.0% and 75.6% using BiliCapture, respectively. CONCLUSIONS: The optical imaging of conjunctiva for bilirubin assay is a safe alternative to a laboratory bilirubin assay and transcutaneous bilirubinometer BiliChek. OMJ 2019-01 /pmc/articles/PMC6330178/ /pubmed/30671181 http://dx.doi.org/10.5001/omj.2019.05 Text en The OMJ is Published Bimonthly and Copyrighted 2019 by the OMSB. This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0). ( https://creativecommons.org/licenses/by-nc/4.0/).
spellingShingle Original Article
Rizvi, Moattar Raza
Alaskar, Farah Mansoor
Albaradie, Raid Saleem
Rizvi, Noor Fatima
Al-Abdulwahab, Khaled
A Novel Non-invasive Technique of Measuring Bilirubin Levels Using BiliCapture
title A Novel Non-invasive Technique of Measuring Bilirubin Levels Using BiliCapture
title_full A Novel Non-invasive Technique of Measuring Bilirubin Levels Using BiliCapture
title_fullStr A Novel Non-invasive Technique of Measuring Bilirubin Levels Using BiliCapture
title_full_unstemmed A Novel Non-invasive Technique of Measuring Bilirubin Levels Using BiliCapture
title_short A Novel Non-invasive Technique of Measuring Bilirubin Levels Using BiliCapture
title_sort novel non-invasive technique of measuring bilirubin levels using bilicapture
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6330178/
https://www.ncbi.nlm.nih.gov/pubmed/30671181
http://dx.doi.org/10.5001/omj.2019.05
work_keys_str_mv AT rizvimoattarraza anovelnoninvasivetechniqueofmeasuringbilirubinlevelsusingbilicapture
AT alaskarfarahmansoor anovelnoninvasivetechniqueofmeasuringbilirubinlevelsusingbilicapture
AT albaradieraidsaleem anovelnoninvasivetechniqueofmeasuringbilirubinlevelsusingbilicapture
AT rizvinoorfatima anovelnoninvasivetechniqueofmeasuringbilirubinlevelsusingbilicapture
AT alabdulwahabkhaled anovelnoninvasivetechniqueofmeasuringbilirubinlevelsusingbilicapture
AT rizvimoattarraza novelnoninvasivetechniqueofmeasuringbilirubinlevelsusingbilicapture
AT alaskarfarahmansoor novelnoninvasivetechniqueofmeasuringbilirubinlevelsusingbilicapture
AT albaradieraidsaleem novelnoninvasivetechniqueofmeasuringbilirubinlevelsusingbilicapture
AT rizvinoorfatima novelnoninvasivetechniqueofmeasuringbilirubinlevelsusingbilicapture
AT alabdulwahabkhaled novelnoninvasivetechniqueofmeasuringbilirubinlevelsusingbilicapture