Cargando…

Fast Simultaneous Determination of 13 Nucleosides and Nucleobases in Cordyceps sinensis by UHPLC–ESI–MS/MS

A reliable ultra-high-performance liquid chromatography–electrospray ionization–tandem mass spectrometry (UHPLC–ESI–MS/MS) method for the fast simultaneous determination of 13 nucleosides and nucleobases in Cordyceps sinensis (C. sinensis) with 2-chloroadenosine as internal standard was developed an...

Descripción completa

Detalles Bibliográficos
Autores principales: Zong, Shi-Yu, Han, Han, Wang, Bing, Li, Ning, Dong, Tina Ting-Xia, Zhang, Tong, Tsim, Karl W. K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6332315/
https://www.ncbi.nlm.nih.gov/pubmed/26690105
http://dx.doi.org/10.3390/molecules201219807
_version_ 1783387322185678848
author Zong, Shi-Yu
Han, Han
Wang, Bing
Li, Ning
Dong, Tina Ting-Xia
Zhang, Tong
Tsim, Karl W. K.
author_facet Zong, Shi-Yu
Han, Han
Wang, Bing
Li, Ning
Dong, Tina Ting-Xia
Zhang, Tong
Tsim, Karl W. K.
author_sort Zong, Shi-Yu
collection PubMed
description A reliable ultra-high-performance liquid chromatography–electrospray ionization–tandem mass spectrometry (UHPLC–ESI–MS/MS) method for the fast simultaneous determination of 13 nucleosides and nucleobases in Cordyceps sinensis (C. sinensis) with 2-chloroadenosine as internal standard was developed and validated. Samples were ultrasonically extracted in an ice bath thrice, and the optimum analyte separation was performed on an ACQUITY UPLC(TM) HSS C18 column (100 mm × 2.1 mm, 1.8 μm) with gradient elution. All targeted analytes were separated in 5.5 min. Furthermore, all calibration curves showed good linear regression (r > 0.9970) within the test ranges, and the limits of quantitation and detection of the 13 analytes were less than 150 and 75 ng/mL, respectively. The relative standard deviations (RSDs) of intra- and inter-day precisions were <6.23%. Recoveries of the quantified analytes ranged within 85.3%–117.3%, with RSD < 6.18%. The developed UHPLC–ESI–MS/MS method was successfully applied to determine nucleosides and nucleobases in 11 batches of C. sinensis samples from different regions in China. The range for the total content in the analyzed samples was 1329–2057 µg/g.
format Online
Article
Text
id pubmed-6332315
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-63323152019-01-24 Fast Simultaneous Determination of 13 Nucleosides and Nucleobases in Cordyceps sinensis by UHPLC–ESI–MS/MS Zong, Shi-Yu Han, Han Wang, Bing Li, Ning Dong, Tina Ting-Xia Zhang, Tong Tsim, Karl W. K. Molecules Article A reliable ultra-high-performance liquid chromatography–electrospray ionization–tandem mass spectrometry (UHPLC–ESI–MS/MS) method for the fast simultaneous determination of 13 nucleosides and nucleobases in Cordyceps sinensis (C. sinensis) with 2-chloroadenosine as internal standard was developed and validated. Samples were ultrasonically extracted in an ice bath thrice, and the optimum analyte separation was performed on an ACQUITY UPLC(TM) HSS C18 column (100 mm × 2.1 mm, 1.8 μm) with gradient elution. All targeted analytes were separated in 5.5 min. Furthermore, all calibration curves showed good linear regression (r > 0.9970) within the test ranges, and the limits of quantitation and detection of the 13 analytes were less than 150 and 75 ng/mL, respectively. The relative standard deviations (RSDs) of intra- and inter-day precisions were <6.23%. Recoveries of the quantified analytes ranged within 85.3%–117.3%, with RSD < 6.18%. The developed UHPLC–ESI–MS/MS method was successfully applied to determine nucleosides and nucleobases in 11 batches of C. sinensis samples from different regions in China. The range for the total content in the analyzed samples was 1329–2057 µg/g. MDPI 2015-12-04 /pmc/articles/PMC6332315/ /pubmed/26690105 http://dx.doi.org/10.3390/molecules201219807 Text en © 2015 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zong, Shi-Yu
Han, Han
Wang, Bing
Li, Ning
Dong, Tina Ting-Xia
Zhang, Tong
Tsim, Karl W. K.
Fast Simultaneous Determination of 13 Nucleosides and Nucleobases in Cordyceps sinensis by UHPLC–ESI–MS/MS
title Fast Simultaneous Determination of 13 Nucleosides and Nucleobases in Cordyceps sinensis by UHPLC–ESI–MS/MS
title_full Fast Simultaneous Determination of 13 Nucleosides and Nucleobases in Cordyceps sinensis by UHPLC–ESI–MS/MS
title_fullStr Fast Simultaneous Determination of 13 Nucleosides and Nucleobases in Cordyceps sinensis by UHPLC–ESI–MS/MS
title_full_unstemmed Fast Simultaneous Determination of 13 Nucleosides and Nucleobases in Cordyceps sinensis by UHPLC–ESI–MS/MS
title_short Fast Simultaneous Determination of 13 Nucleosides and Nucleobases in Cordyceps sinensis by UHPLC–ESI–MS/MS
title_sort fast simultaneous determination of 13 nucleosides and nucleobases in cordyceps sinensis by uhplc–esi–ms/ms
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6332315/
https://www.ncbi.nlm.nih.gov/pubmed/26690105
http://dx.doi.org/10.3390/molecules201219807
work_keys_str_mv AT zongshiyu fastsimultaneousdeterminationof13nucleosidesandnucleobasesincordycepssinensisbyuhplcesimsms
AT hanhan fastsimultaneousdeterminationof13nucleosidesandnucleobasesincordycepssinensisbyuhplcesimsms
AT wangbing fastsimultaneousdeterminationof13nucleosidesandnucleobasesincordycepssinensisbyuhplcesimsms
AT lining fastsimultaneousdeterminationof13nucleosidesandnucleobasesincordycepssinensisbyuhplcesimsms
AT dongtinatingxia fastsimultaneousdeterminationof13nucleosidesandnucleobasesincordycepssinensisbyuhplcesimsms
AT zhangtong fastsimultaneousdeterminationof13nucleosidesandnucleobasesincordycepssinensisbyuhplcesimsms
AT tsimkarlwk fastsimultaneousdeterminationof13nucleosidesandnucleobasesincordycepssinensisbyuhplcesimsms