Cargando…
Development process of a mobile electronic medical record for nurses: a single case study
BACKGROUND: With the growing shortage of nurses, labor-saving technology has become more important. In health care practice, however, the fit with innovations is not easy. The aim of this study is to analyze the development of a mobile input device for electronic medical records (MEMR), a potentiall...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6332569/ https://www.ncbi.nlm.nih.gov/pubmed/30642324 http://dx.doi.org/10.1186/s12911-018-0726-3 |
_version_ | 1783387381142913024 |
---|---|
author | Vossebeld, Danielle M. Puik, Erik C. N. Jaspers, Joris E. N. Schuurmans, Marieke J. |
author_facet | Vossebeld, Danielle M. Puik, Erik C. N. Jaspers, Joris E. N. Schuurmans, Marieke J. |
author_sort | Vossebeld, Danielle M. |
collection | PubMed |
description | BACKGROUND: With the growing shortage of nurses, labor-saving technology has become more important. In health care practice, however, the fit with innovations is not easy. The aim of this study is to analyze the development of a mobile input device for electronic medical records (MEMR), a potentially labor-saving application supported by nurses, that failed to meet the needs of nurses after development. METHOD: In a case study, we used an axiomatic design framework as an evaluation tool to visualize the mismatches between customer needs and the design parameters of the MEMR, and trace these mismatches back to (preliminary) decisions in the development process. We applied a mixed-method research design that consisted of analyzing of 118 external and internal files and working documents, 29 interviews and shorter inquiries, a user test, and an observation of use. By factoring and grouping the findings, we analyzed the relevant categories of mismatches. RESULTS: The involvement of nurses during the development was extensive, but not all feedback was, or could not be, used effectively to improve the MEMR. The mismatches with the most impact were found to be: (1) suboptimal supportive technology, (2) limited functionality of the app and input device, and (3) disruption of nurses’ workflow. Most mismatches were known by the IT department when the MEMR was offered to the units as a product. Development of the MEMR came to a halt because of limited use. CONCLUSION: Choices for design parameters, made during the development of labor-saving technology for nurses, may conflict with the customer needs of nurses. Even though the causes of mismatches were mentioned by the IT department, the nurse managers acquired the MEMR based on the idea behind the app. The effects of the chosen design parameters should not only be compared to the customer needs, but also be assessed with nurses and nurse managers for the expected effect on the workflow. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12911-018-0726-3) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6332569 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-63325692019-01-16 Development process of a mobile electronic medical record for nurses: a single case study Vossebeld, Danielle M. Puik, Erik C. N. Jaspers, Joris E. N. Schuurmans, Marieke J. BMC Med Inform Decis Mak Research Article BACKGROUND: With the growing shortage of nurses, labor-saving technology has become more important. In health care practice, however, the fit with innovations is not easy. The aim of this study is to analyze the development of a mobile input device for electronic medical records (MEMR), a potentially labor-saving application supported by nurses, that failed to meet the needs of nurses after development. METHOD: In a case study, we used an axiomatic design framework as an evaluation tool to visualize the mismatches between customer needs and the design parameters of the MEMR, and trace these mismatches back to (preliminary) decisions in the development process. We applied a mixed-method research design that consisted of analyzing of 118 external and internal files and working documents, 29 interviews and shorter inquiries, a user test, and an observation of use. By factoring and grouping the findings, we analyzed the relevant categories of mismatches. RESULTS: The involvement of nurses during the development was extensive, but not all feedback was, or could not be, used effectively to improve the MEMR. The mismatches with the most impact were found to be: (1) suboptimal supportive technology, (2) limited functionality of the app and input device, and (3) disruption of nurses’ workflow. Most mismatches were known by the IT department when the MEMR was offered to the units as a product. Development of the MEMR came to a halt because of limited use. CONCLUSION: Choices for design parameters, made during the development of labor-saving technology for nurses, may conflict with the customer needs of nurses. Even though the causes of mismatches were mentioned by the IT department, the nurse managers acquired the MEMR based on the idea behind the app. The effects of the chosen design parameters should not only be compared to the customer needs, but also be assessed with nurses and nurse managers for the expected effect on the workflow. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12911-018-0726-3) contains supplementary material, which is available to authorized users. BioMed Central 2019-01-14 /pmc/articles/PMC6332569/ /pubmed/30642324 http://dx.doi.org/10.1186/s12911-018-0726-3 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Vossebeld, Danielle M. Puik, Erik C. N. Jaspers, Joris E. N. Schuurmans, Marieke J. Development process of a mobile electronic medical record for nurses: a single case study |
title | Development process of a mobile electronic medical record for nurses: a single case study |
title_full | Development process of a mobile electronic medical record for nurses: a single case study |
title_fullStr | Development process of a mobile electronic medical record for nurses: a single case study |
title_full_unstemmed | Development process of a mobile electronic medical record for nurses: a single case study |
title_short | Development process of a mobile electronic medical record for nurses: a single case study |
title_sort | development process of a mobile electronic medical record for nurses: a single case study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6332569/ https://www.ncbi.nlm.nih.gov/pubmed/30642324 http://dx.doi.org/10.1186/s12911-018-0726-3 |
work_keys_str_mv | AT vossebelddaniellem developmentprocessofamobileelectronicmedicalrecordfornursesasinglecasestudy AT puikerikcn developmentprocessofamobileelectronicmedicalrecordfornursesasinglecasestudy AT jaspersjorisen developmentprocessofamobileelectronicmedicalrecordfornursesasinglecasestudy AT schuurmansmariekej developmentprocessofamobileelectronicmedicalrecordfornursesasinglecasestudy |