An effective method to reduce the interplay effects between respiratory motion and a uniform scanning proton beam irradiation for liver tumors: A case study

PURPOSE: For scanning particle beam therapy, interference between scanning patterns and interfield organ motion may result in suboptimal dose within target volume. In this study, we developed a simple offline correction technique for uniform scanning proton beam (USPB) delivery to compensate for the...

Descripción completa

Detalles Bibliográficos
Autores principales: Akino, Yuichi, Wu, Huanmei, Oh, Ryoong‐Jin, Das, Indra J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6333118/
https://www.ncbi.nlm.nih.gov/pubmed/30548791
http://dx.doi.org/10.1002/acm2.12508
_version_ 1783387503747661824
author Akino, Yuichi
Wu, Huanmei
Oh, Ryoong‐Jin
Das, Indra J.
author_facet Akino, Yuichi
Wu, Huanmei
Oh, Ryoong‐Jin
Das, Indra J.
author_sort Akino, Yuichi
collection PubMed
description PURPOSE: For scanning particle beam therapy, interference between scanning patterns and interfield organ motion may result in suboptimal dose within target volume. In this study, we developed a simple offline correction technique for uniform scanning proton beam (USPB) delivery to compensate for the interplay between scanning patterns and respiratory motion and demonstrate the effectiveness of our technique in treating liver cancer. METHODS: The computed tomography (CT) and respiration data of two patients who had received stereotactic body radiotherapy for hepatocellular carcinoma were used. In the simulation, the relative beam weight delivered to each respiratory phase is calculated for each beam layer after treatment of each fraction. Respiratory phases with beam weights higher than 50% of the largest weight are considered “skipped phases” for the next fraction. For the following fraction, the beam trigger is regulated to prevent beam layers from starting irradiation in skipped phases by extending the interval between each layer. To calculate dose‐volume histogram (DVH), the dose of the target volume at end‐exhale (50% phase) was calculated as the sum of each energy layer, with consideration of displacement due to respiratory motion and relative beam weight delivered per respiratory phase. RESULTS: For a single fraction, D(1%), D(99%), and V(100%) were 114%, 88%, and 32%, respectively, when 8 Gy/min of dose rate was simulated. Although these parameters were improved with multiple fractions, dosimetric inhomogeneity without motion management remained even at 30 fractions, with V(100%) 86.9% at 30 fractions. In contrast, the V(100%) values with adaptation were 96% and 98% at 20 and 30 fractions, respectively. We developed an offline correction technique for USPB therapy to compensate for the interplay effects between respiratory organ motion and USPB beam delivery. CONCLUSIONS: For liver tumor, this adaptive therapy technique showed significant improvement in dose uniformity even with fewer treatment fractions than normal USPB therapy.
format Online
Article
Text
id pubmed-6333118
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-63331182019-01-23 An effective method to reduce the interplay effects between respiratory motion and a uniform scanning proton beam irradiation for liver tumors: A case study Akino, Yuichi Wu, Huanmei Oh, Ryoong‐Jin Das, Indra J. J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: For scanning particle beam therapy, interference between scanning patterns and interfield organ motion may result in suboptimal dose within target volume. In this study, we developed a simple offline correction technique for uniform scanning proton beam (USPB) delivery to compensate for the interplay between scanning patterns and respiratory motion and demonstrate the effectiveness of our technique in treating liver cancer. METHODS: The computed tomography (CT) and respiration data of two patients who had received stereotactic body radiotherapy for hepatocellular carcinoma were used. In the simulation, the relative beam weight delivered to each respiratory phase is calculated for each beam layer after treatment of each fraction. Respiratory phases with beam weights higher than 50% of the largest weight are considered “skipped phases” for the next fraction. For the following fraction, the beam trigger is regulated to prevent beam layers from starting irradiation in skipped phases by extending the interval between each layer. To calculate dose‐volume histogram (DVH), the dose of the target volume at end‐exhale (50% phase) was calculated as the sum of each energy layer, with consideration of displacement due to respiratory motion and relative beam weight delivered per respiratory phase. RESULTS: For a single fraction, D(1%), D(99%), and V(100%) were 114%, 88%, and 32%, respectively, when 8 Gy/min of dose rate was simulated. Although these parameters were improved with multiple fractions, dosimetric inhomogeneity without motion management remained even at 30 fractions, with V(100%) 86.9% at 30 fractions. In contrast, the V(100%) values with adaptation were 96% and 98% at 20 and 30 fractions, respectively. We developed an offline correction technique for USPB therapy to compensate for the interplay effects between respiratory organ motion and USPB beam delivery. CONCLUSIONS: For liver tumor, this adaptive therapy technique showed significant improvement in dose uniformity even with fewer treatment fractions than normal USPB therapy. John Wiley and Sons Inc. 2018-12-13 /pmc/articles/PMC6333118/ /pubmed/30548791 http://dx.doi.org/10.1002/acm2.12508 Text en © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Akino, Yuichi
Wu, Huanmei
Oh, Ryoong‐Jin
Das, Indra J.
An effective method to reduce the interplay effects between respiratory motion and a uniform scanning proton beam irradiation for liver tumors: A case study
title An effective method to reduce the interplay effects between respiratory motion and a uniform scanning proton beam irradiation for liver tumors: A case study
title_full An effective method to reduce the interplay effects between respiratory motion and a uniform scanning proton beam irradiation for liver tumors: A case study
title_fullStr An effective method to reduce the interplay effects between respiratory motion and a uniform scanning proton beam irradiation for liver tumors: A case study
title_full_unstemmed An effective method to reduce the interplay effects between respiratory motion and a uniform scanning proton beam irradiation for liver tumors: A case study
title_short An effective method to reduce the interplay effects between respiratory motion and a uniform scanning proton beam irradiation for liver tumors: A case study
title_sort effective method to reduce the interplay effects between respiratory motion and a uniform scanning proton beam irradiation for liver tumors: a case study
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6333118/
https://www.ncbi.nlm.nih.gov/pubmed/30548791
http://dx.doi.org/10.1002/acm2.12508
work_keys_str_mv AT akinoyuichi aneffectivemethodtoreducetheinterplayeffectsbetweenrespiratorymotionandauniformscanningprotonbeamirradiationforlivertumorsacasestudy
AT wuhuanmei aneffectivemethodtoreducetheinterplayeffectsbetweenrespiratorymotionandauniformscanningprotonbeamirradiationforlivertumorsacasestudy
AT ohryoongjin aneffectivemethodtoreducetheinterplayeffectsbetweenrespiratorymotionandauniformscanningprotonbeamirradiationforlivertumorsacasestudy
AT dasindraj aneffectivemethodtoreducetheinterplayeffectsbetweenrespiratorymotionandauniformscanningprotonbeamirradiationforlivertumorsacasestudy
AT akinoyuichi effectivemethodtoreducetheinterplayeffectsbetweenrespiratorymotionandauniformscanningprotonbeamirradiationforlivertumorsacasestudy
AT wuhuanmei effectivemethodtoreducetheinterplayeffectsbetweenrespiratorymotionandauniformscanningprotonbeamirradiationforlivertumorsacasestudy
AT ohryoongjin effectivemethodtoreducetheinterplayeffectsbetweenrespiratorymotionandauniformscanningprotonbeamirradiationforlivertumorsacasestudy
AT dasindraj effectivemethodtoreducetheinterplayeffectsbetweenrespiratorymotionandauniformscanningprotonbeamirradiationforlivertumorsacasestudy