Cargando…
Steeper dose gradients resulting from reduced source to target distance—a planning system independent study
PURPOSE: To quantify the contribution of penumbra in the improvement of healthy tissue sparing at reduced source‐to‐axis distance (SAD) for simple spherical target and different prescription isodoses (PI). METHOD: A TPS‐independent method was used to estimate three‐dimensional (3D) dose distribution...
Autores principales: | Bratengeier, Klaus, Holubyev, Kostyantyn, Wegener, Sonja |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6333151/ https://www.ncbi.nlm.nih.gov/pubmed/30412346 http://dx.doi.org/10.1002/acm2.12490 |
Ejemplares similares
-
Finer leaf resolution and steeper beam edges using a virtual isocentre in concurrence to PTV-shaped collimators in standard distance – a planning study
por: Bratengeier, Klaus, et al.
Publicado: (2017) -
Characteristics of non-coplanar IMRT in the presence of target-embedded organs at risk
por: Bratengeier, Klaus, et al.
Publicado: (2015) -
Towards automated on-line adaptation of 2-Step IMRT plans: QUASIMODO phantom and prostate cancer cases
por: Holubyev, Kostyantyn, et al.
Publicado: (2013) -
Sensitivity and specificity of secondary dose calculation for head and neck treatment plans
por: Wegener, Sonja, et al.
Publicado: (2023) -
Dosimetric evaluation of a spinal cord dose‐limiting 3D‐CRT technique for radiotherapy of spinal metastases
por: Arnold, Christian Cornelius, et al.
Publicado: (2023)