Cargando…
Augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: A randomized controlled trial
BACKGROUND: During intubation with a blind technique, a left-sided double-lumen tube (DLT) can be misdirected into the right bronchus even though its curved tip of the bronchial lumen turns to the left. This right bronchial misplacement may be associated with the tip angle of DLTs. We thus performed...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6333363/ https://www.ncbi.nlm.nih.gov/pubmed/30645611 http://dx.doi.org/10.1371/journal.pone.0210711 |
_version_ | 1783387549996154880 |
---|---|
author | Seo, Jeong-Hwa Yoon, Susie Min, Se-Hee Row, Hyung Sang Bahk, Jae-Hyon |
author_facet | Seo, Jeong-Hwa Yoon, Susie Min, Se-Hee Row, Hyung Sang Bahk, Jae-Hyon |
author_sort | Seo, Jeong-Hwa |
collection | PubMed |
description | BACKGROUND: During intubation with a blind technique, a left-sided double-lumen tube (DLT) can be misdirected into the right bronchus even though its curved tip of the bronchial lumen turns to the left. This right bronchial misplacement may be associated with the tip angle of DLTs. We thus performed a randomized trial to test the hypothesis that the DLT with an acute tip angle enters the right bronchus less frequently than the tube with an obtuse tip angle. METHODS: We randomized surgical patients (n = 1427) receiving a polyvinyl chloride left-sided DLT. Before intubation, the curved tip was further bent to an angle of 135° and kept with a stylet inside in the curved-tip group, but not in the control group. After the tip was inserted into the glottis under direct or video laryngoscopy, the stylet was removed and the DLT was advanced into the bronchus with its tip turning to the left. We checked which bronchus was intubated, and the time and number of attempts for intubation. After surgery, we assessed airway injury, sore throat, and hoarseness. The primary outcome was the incidence of right bronchial misplacement of the DLT. RESULTS: DLTs were misdirected into the right bronchus more frequently in the control group than in the curved-tip group: 57/715 (8.0%) vs 17/712 (2.4%), risk ratio (95% CI) 3.3 (2.0–5.7), P < 0.001. The difference was significant in the use of 32 (P = 0.003), 35 (P = 0.007), and 37 (P = 0.012) Fr DLTs. Intubation required longer time (P < 0.001) and more attempts (P = 0.002) in the control group. No differences were found in postoperative airway injury, sore throat and hoarseness. CONCLUSIONS: Before intubation of left-sided DLTs, augmentation of the curved DLT tip reduced the right bronchial misplacement and facilitated intubation without aggravating airway injury. |
format | Online Article Text |
id | pubmed-6333363 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-63333632019-01-31 Augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: A randomized controlled trial Seo, Jeong-Hwa Yoon, Susie Min, Se-Hee Row, Hyung Sang Bahk, Jae-Hyon PLoS One Research Article BACKGROUND: During intubation with a blind technique, a left-sided double-lumen tube (DLT) can be misdirected into the right bronchus even though its curved tip of the bronchial lumen turns to the left. This right bronchial misplacement may be associated with the tip angle of DLTs. We thus performed a randomized trial to test the hypothesis that the DLT with an acute tip angle enters the right bronchus less frequently than the tube with an obtuse tip angle. METHODS: We randomized surgical patients (n = 1427) receiving a polyvinyl chloride left-sided DLT. Before intubation, the curved tip was further bent to an angle of 135° and kept with a stylet inside in the curved-tip group, but not in the control group. After the tip was inserted into the glottis under direct or video laryngoscopy, the stylet was removed and the DLT was advanced into the bronchus with its tip turning to the left. We checked which bronchus was intubated, and the time and number of attempts for intubation. After surgery, we assessed airway injury, sore throat, and hoarseness. The primary outcome was the incidence of right bronchial misplacement of the DLT. RESULTS: DLTs were misdirected into the right bronchus more frequently in the control group than in the curved-tip group: 57/715 (8.0%) vs 17/712 (2.4%), risk ratio (95% CI) 3.3 (2.0–5.7), P < 0.001. The difference was significant in the use of 32 (P = 0.003), 35 (P = 0.007), and 37 (P = 0.012) Fr DLTs. Intubation required longer time (P < 0.001) and more attempts (P = 0.002) in the control group. No differences were found in postoperative airway injury, sore throat and hoarseness. CONCLUSIONS: Before intubation of left-sided DLTs, augmentation of the curved DLT tip reduced the right bronchial misplacement and facilitated intubation without aggravating airway injury. Public Library of Science 2019-01-15 /pmc/articles/PMC6333363/ /pubmed/30645611 http://dx.doi.org/10.1371/journal.pone.0210711 Text en © 2019 Seo et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Seo, Jeong-Hwa Yoon, Susie Min, Se-Hee Row, Hyung Sang Bahk, Jae-Hyon Augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: A randomized controlled trial |
title | Augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: A randomized controlled trial |
title_full | Augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: A randomized controlled trial |
title_fullStr | Augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: A randomized controlled trial |
title_full_unstemmed | Augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: A randomized controlled trial |
title_short | Augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: A randomized controlled trial |
title_sort | augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: a randomized controlled trial |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6333363/ https://www.ncbi.nlm.nih.gov/pubmed/30645611 http://dx.doi.org/10.1371/journal.pone.0210711 |
work_keys_str_mv | AT seojeonghwa augmentationofcurvedtipofleftsideddoublelumentubestoreducerightbronchialmisplacementarandomizedcontrolledtrial AT yoonsusie augmentationofcurvedtipofleftsideddoublelumentubestoreducerightbronchialmisplacementarandomizedcontrolledtrial AT minsehee augmentationofcurvedtipofleftsideddoublelumentubestoreducerightbronchialmisplacementarandomizedcontrolledtrial AT rowhyungsang augmentationofcurvedtipofleftsideddoublelumentubestoreducerightbronchialmisplacementarandomizedcontrolledtrial AT bahkjaehyon augmentationofcurvedtipofleftsideddoublelumentubestoreducerightbronchialmisplacementarandomizedcontrolledtrial |