Cargando…
Improved beta-amyloid PET reproducibility using two-phase acquisition and grey matter delineation
PURPOSE: We investigated whether the reproducibility of standard visual reporting (STD method) in flutemetamol (FMM) PET can be improved using a newly introduced method that uses grey matter edges derived from the perfusion phase (GM-EDGE method). METHODS: Two-phase FMM PET was performed in 121 pati...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6333723/ https://www.ncbi.nlm.nih.gov/pubmed/30159586 http://dx.doi.org/10.1007/s00259-018-4140-y |
_version_ | 1783387607688806400 |
---|---|
author | Belohlavek, Otakar Jaruskova, Monika Skopalova, Magdalena Szarazova, Gabriela Simonova, Katerina |
author_facet | Belohlavek, Otakar Jaruskova, Monika Skopalova, Magdalena Szarazova, Gabriela Simonova, Katerina |
author_sort | Belohlavek, Otakar |
collection | PubMed |
description | PURPOSE: We investigated whether the reproducibility of standard visual reporting (STD method) in flutemetamol (FMM) PET can be improved using a newly introduced method that uses grey matter edges derived from the perfusion phase (GM-EDGE method). METHODS: Two-phase FMM PET was performed in 121 patients with mild cognitive impairment. Five nuclear medicine physicians blindly and independently evaluated all late-phase scans, initially employing the STD method and later the GM-EDGE method. A five-point scale was used to express the degree of amyloid positivity, and a binary classification (positive/negative) was used in combination with subjective confidence (five-point scale). Multirater Fleiss’ kappa, intraclass correlation coefficient (ICC) and inter-rater reliability (Cohen’s kappa) were determined for the STD and GM-EDGE methods. RESULTS: The weighted Cohen’s kappa values for the five-point measure of amyloid positivity ranged from 0.63 to 0.73 (median 0.70) for the STD method and from 0.76 to 0.89 (median 0.80) for the GM-EDGE method (ICC 0.84, 95% CI 0.79–0.88, for the STD method; 0.91, 95% CI 0.89–0.94, for the GM-EDGE method). The nonweighted Cohen’s kappa value for the binary classification ranged from 0.73 to 0.93 (median 0.82) for the STD method and 0.90 to 0.97 (median 0.93) for the GM-EDGE method (Fleiss’ kappa 0.82, 95% CI 0.77–0.88, for the STD method; 0.93, 95% CI 0.87–0.99, for the GM-EDGE method). The GM-EDGE method resulted in significantly greater subjective confidence in the readings of four physicians (p < 0.010). The binary classification was concordant among all five physicians in 80.8% of the scans using the STD method and in 91.6% of the scans using the GM-EDGE method (p = 0.016). CONCLUSION: The newly introduced GM-EDGE method was associated with significantly higher inter-rater agreement among physicians and higher subjective confidence in the reading. The method is easy to implement in clinical practice, especially when the perfusion phase is utilized clinically. |
format | Online Article Text |
id | pubmed-6333723 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-63337232019-01-27 Improved beta-amyloid PET reproducibility using two-phase acquisition and grey matter delineation Belohlavek, Otakar Jaruskova, Monika Skopalova, Magdalena Szarazova, Gabriela Simonova, Katerina Eur J Nucl Med Mol Imaging Original Article PURPOSE: We investigated whether the reproducibility of standard visual reporting (STD method) in flutemetamol (FMM) PET can be improved using a newly introduced method that uses grey matter edges derived from the perfusion phase (GM-EDGE method). METHODS: Two-phase FMM PET was performed in 121 patients with mild cognitive impairment. Five nuclear medicine physicians blindly and independently evaluated all late-phase scans, initially employing the STD method and later the GM-EDGE method. A five-point scale was used to express the degree of amyloid positivity, and a binary classification (positive/negative) was used in combination with subjective confidence (five-point scale). Multirater Fleiss’ kappa, intraclass correlation coefficient (ICC) and inter-rater reliability (Cohen’s kappa) were determined for the STD and GM-EDGE methods. RESULTS: The weighted Cohen’s kappa values for the five-point measure of amyloid positivity ranged from 0.63 to 0.73 (median 0.70) for the STD method and from 0.76 to 0.89 (median 0.80) for the GM-EDGE method (ICC 0.84, 95% CI 0.79–0.88, for the STD method; 0.91, 95% CI 0.89–0.94, for the GM-EDGE method). The nonweighted Cohen’s kappa value for the binary classification ranged from 0.73 to 0.93 (median 0.82) for the STD method and 0.90 to 0.97 (median 0.93) for the GM-EDGE method (Fleiss’ kappa 0.82, 95% CI 0.77–0.88, for the STD method; 0.93, 95% CI 0.87–0.99, for the GM-EDGE method). The GM-EDGE method resulted in significantly greater subjective confidence in the readings of four physicians (p < 0.010). The binary classification was concordant among all five physicians in 80.8% of the scans using the STD method and in 91.6% of the scans using the GM-EDGE method (p = 0.016). CONCLUSION: The newly introduced GM-EDGE method was associated with significantly higher inter-rater agreement among physicians and higher subjective confidence in the reading. The method is easy to implement in clinical practice, especially when the perfusion phase is utilized clinically. Springer Berlin Heidelberg 2018-08-29 2019 /pmc/articles/PMC6333723/ /pubmed/30159586 http://dx.doi.org/10.1007/s00259-018-4140-y Text en © The Author(s) 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Belohlavek, Otakar Jaruskova, Monika Skopalova, Magdalena Szarazova, Gabriela Simonova, Katerina Improved beta-amyloid PET reproducibility using two-phase acquisition and grey matter delineation |
title | Improved beta-amyloid PET reproducibility using two-phase acquisition and grey matter delineation |
title_full | Improved beta-amyloid PET reproducibility using two-phase acquisition and grey matter delineation |
title_fullStr | Improved beta-amyloid PET reproducibility using two-phase acquisition and grey matter delineation |
title_full_unstemmed | Improved beta-amyloid PET reproducibility using two-phase acquisition and grey matter delineation |
title_short | Improved beta-amyloid PET reproducibility using two-phase acquisition and grey matter delineation |
title_sort | improved beta-amyloid pet reproducibility using two-phase acquisition and grey matter delineation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6333723/ https://www.ncbi.nlm.nih.gov/pubmed/30159586 http://dx.doi.org/10.1007/s00259-018-4140-y |
work_keys_str_mv | AT belohlavekotakar improvedbetaamyloidpetreproducibilityusingtwophaseacquisitionandgreymatterdelineation AT jaruskovamonika improvedbetaamyloidpetreproducibilityusingtwophaseacquisitionandgreymatterdelineation AT skopalovamagdalena improvedbetaamyloidpetreproducibilityusingtwophaseacquisitionandgreymatterdelineation AT szarazovagabriela improvedbetaamyloidpetreproducibilityusingtwophaseacquisitionandgreymatterdelineation AT simonovakaterina improvedbetaamyloidpetreproducibilityusingtwophaseacquisitionandgreymatterdelineation |