Cargando…
Threshold voltage decrease in a thermotropic nematic liquid crystal doped with graphene oxide flakes
We report a threshold voltage decrease in a nematic liquid crystal compound, 4-cyano-4′-pentylbiphenyl (5CB), doped with graphene oxide (GO) flakes at a concentration of 0.05–0.3 wt %. The threshold voltage decrease was observed at the same concentration in electro-optic and dielectric spectroscopy...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Beilstein-Institut
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6334787/ https://www.ncbi.nlm.nih.gov/pubmed/30680280 http://dx.doi.org/10.3762/bjnano.10.7 |
_version_ | 1783387785371058176 |
---|---|
author | Mrukiewicz, Mateusz Kowiorski, Krystian Perkowski, Paweł Mazur, Rafał Djas, Małgorzata |
author_facet | Mrukiewicz, Mateusz Kowiorski, Krystian Perkowski, Paweł Mazur, Rafał Djas, Małgorzata |
author_sort | Mrukiewicz, Mateusz |
collection | PubMed |
description | We report a threshold voltage decrease in a nematic liquid crystal compound, 4-cyano-4′-pentylbiphenyl (5CB), doped with graphene oxide (GO) flakes at a concentration of 0.05–0.3 wt %. The threshold voltage decrease was observed at the same concentration in electro-optic and dielectric spectroscopy measurements. The effect is related to the disrupted planar alignment due to the strong π–π stacking between the 5CB’s benzene rings and the graphene oxide’s structure. Additionally, we present the GO concentration dependence on the isotropic–nematic phase transition temperature, electric anisotropy, splay elastic constant, switch-on time, and switch-off time. The shape and dimensions of the GO flakes were studied using atomic force microscopy (AFM) and scanning electron microscopy (SEM). The influence of the GO concentration on the physical properties and switching process in the presence of the electric field was discussed. |
format | Online Article Text |
id | pubmed-6334787 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Beilstein-Institut |
record_format | MEDLINE/PubMed |
spelling | pubmed-63347872019-01-24 Threshold voltage decrease in a thermotropic nematic liquid crystal doped with graphene oxide flakes Mrukiewicz, Mateusz Kowiorski, Krystian Perkowski, Paweł Mazur, Rafał Djas, Małgorzata Beilstein J Nanotechnol Full Research Paper We report a threshold voltage decrease in a nematic liquid crystal compound, 4-cyano-4′-pentylbiphenyl (5CB), doped with graphene oxide (GO) flakes at a concentration of 0.05–0.3 wt %. The threshold voltage decrease was observed at the same concentration in electro-optic and dielectric spectroscopy measurements. The effect is related to the disrupted planar alignment due to the strong π–π stacking between the 5CB’s benzene rings and the graphene oxide’s structure. Additionally, we present the GO concentration dependence on the isotropic–nematic phase transition temperature, electric anisotropy, splay elastic constant, switch-on time, and switch-off time. The shape and dimensions of the GO flakes were studied using atomic force microscopy (AFM) and scanning electron microscopy (SEM). The influence of the GO concentration on the physical properties and switching process in the presence of the electric field was discussed. Beilstein-Institut 2019-01-07 /pmc/articles/PMC6334787/ /pubmed/30680280 http://dx.doi.org/10.3762/bjnano.10.7 Text en Copyright © 2019, Mrukiewicz et al. https://creativecommons.org/licenses/by/4.0https://www.beilstein-journals.org/bjnano/termsThis is an Open Access article under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0). Please note that the reuse, redistribution and reproduction in particular requires that the authors and source are credited. The license is subject to the Beilstein Journal of Nanotechnology terms and conditions: (https://www.beilstein-journals.org/bjnano/terms) |
spellingShingle | Full Research Paper Mrukiewicz, Mateusz Kowiorski, Krystian Perkowski, Paweł Mazur, Rafał Djas, Małgorzata Threshold voltage decrease in a thermotropic nematic liquid crystal doped with graphene oxide flakes |
title | Threshold voltage decrease in a thermotropic nematic liquid crystal doped with graphene oxide flakes |
title_full | Threshold voltage decrease in a thermotropic nematic liquid crystal doped with graphene oxide flakes |
title_fullStr | Threshold voltage decrease in a thermotropic nematic liquid crystal doped with graphene oxide flakes |
title_full_unstemmed | Threshold voltage decrease in a thermotropic nematic liquid crystal doped with graphene oxide flakes |
title_short | Threshold voltage decrease in a thermotropic nematic liquid crystal doped with graphene oxide flakes |
title_sort | threshold voltage decrease in a thermotropic nematic liquid crystal doped with graphene oxide flakes |
topic | Full Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6334787/ https://www.ncbi.nlm.nih.gov/pubmed/30680280 http://dx.doi.org/10.3762/bjnano.10.7 |
work_keys_str_mv | AT mrukiewiczmateusz thresholdvoltagedecreaseinathermotropicnematicliquidcrystaldopedwithgrapheneoxideflakes AT kowiorskikrystian thresholdvoltagedecreaseinathermotropicnematicliquidcrystaldopedwithgrapheneoxideflakes AT perkowskipaweł thresholdvoltagedecreaseinathermotropicnematicliquidcrystaldopedwithgrapheneoxideflakes AT mazurrafał thresholdvoltagedecreaseinathermotropicnematicliquidcrystaldopedwithgrapheneoxideflakes AT djasmałgorzata thresholdvoltagedecreaseinathermotropicnematicliquidcrystaldopedwithgrapheneoxideflakes |