Cargando…
Diagnostic yield and risk/benefit analysis of trans-bronchial lung cryobiopsy in diffuse parenchymal lung diseases: a large cohort of 699 patients
BACKGROUND: Standardization of trans-bronchial lung cryobiopsy in diffuse parenchymal lung diseases is imminent; however, the majority of published series on cryobiopsy include a limited number of patients and are characterized by several differences in procedural technical details. METHODS: This is...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6335717/ https://www.ncbi.nlm.nih.gov/pubmed/30651103 http://dx.doi.org/10.1186/s12890-019-0780-3 |
Sumario: | BACKGROUND: Standardization of trans-bronchial lung cryobiopsy in diffuse parenchymal lung diseases is imminent; however, the majority of published series on cryobiopsy include a limited number of patients and are characterized by several differences in procedural technical details. METHODS: This is an observational, retrospective cohort study. Aim of the study was to suggest some sampling strategies related to transbronchial cryobiopsy in the diagnostic work-up of patients with diffuse parenchymal lung diseases. RESULTS: Six hundred ninety-nine patients with suspected diffuse parenchymal lung disease were recruited. A specific pathological diagnosis was achieved in 614/699 cases (87.8%) and a multidisciplinary diagnosis was obtained in 630/699 cases (90.1%). Diagnostic yield was significantly influenced by the number of samples taken (1 vs ≥ 2 biopsies, p < 0.005). In 60.4% of patients, biopsies were taken from one site and in 39.6% from different sites (in the same lobe or in two different lobes), with a significant increase in diagnostic yield, specifically in patients with fibrotic lung diseases (65.5% vs 93.4%, p < 0.0001). The 2.4 mm or 1.9 mm probes were used, with no differences in terms of diagnostic yield. Regarding safety, pneumothorax occurred in 19.2% and was influenced by baseline lung function; in all patients Fogarty balloon has been used and severe haemorrhage occurred in 0.7% of cases. Three patients (0.4% of cases) died within 30 days after the procedure. CONCLUSIONS: We propose some sampling strategies of cryobiopsy which seem to be associated with a higher diagnostic yield and a favorable risk/benefit ratio: sampling at least two samples in different sites, using either the 2.4 mm or the 1.9 mm probe, intubating the patients and using bronchial blockers/catheters. |
---|