Cargando…

Comparison between LigaSure™ and Harmonic® in Laparoscopic Sleeve Gastrectomy: A Single-Center Experience on 422 Patients

BACKGROUND: New laparoscopic devices, such as electrothermal bipolar-activated devices (LigaSure™ (LS)) or ultrasonic systems (Harmonic® scalpel (HS)), have been applied recently to bariatric surgery allowing to reduce blood loss and surgical risks. The aim of this study was to retrospectively compa...

Descripción completa

Detalles Bibliográficos
Autores principales: Velotti, N., Manigrasso, M., Di Lauro, K., Vitiello, A., Berardi, G., Manzolillo, D., Anoldo, P., Bocchetti, A., Milone, F., Milone, M., De Palma, G. D., Musella, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6335858/
https://www.ncbi.nlm.nih.gov/pubmed/30719344
http://dx.doi.org/10.1155/2019/3402137
_version_ 1783387974809944064
author Velotti, N.
Manigrasso, M.
Di Lauro, K.
Vitiello, A.
Berardi, G.
Manzolillo, D.
Anoldo, P.
Bocchetti, A.
Milone, F.
Milone, M.
De Palma, G. D.
Musella, M.
author_facet Velotti, N.
Manigrasso, M.
Di Lauro, K.
Vitiello, A.
Berardi, G.
Manzolillo, D.
Anoldo, P.
Bocchetti, A.
Milone, F.
Milone, M.
De Palma, G. D.
Musella, M.
author_sort Velotti, N.
collection PubMed
description BACKGROUND: New laparoscopic devices, such as electrothermal bipolar-activated devices (LigaSure™ (LS)) or ultrasonic systems (Harmonic® scalpel (HS)), have been applied recently to bariatric surgery allowing to reduce blood loss and surgical risks. The aim of this study was to retrospectively compare intraoperative performance of HS and LS, postoperative results, and clinical outcomes in a large cohort of patients undergoing LSG. METHODS: Data from 422 morbidly obese patients undergoing LSG in our Bariatric Unit at the Advanced Biomedical Sciences Department of the “Federico II” University of Naples (Italy) between January 2009 and December 2017 were retrospectively analyzed. Subjects were divided into two groups (HS and LS), and operative time, intraoperative complications, and postoperative (within 30 days from surgery) complications were compared. Bleeding from the omentum or from the staple line, use of hemostatic clips, and absorbable hemostat were recorded as intraoperative complications; hemorrhages, abscess formation, gastric leaks, fever, and mortality were considered as postoperative complications. RESULTS: Statistical analysis showed no difference in terms of baseline demographics between the two cohorts. Operative time (48 ± 9 vs 49 ± 6 min, p=0.646) and the rates of intraoperative and postoperative complications did not significantly differ between groups. CONCLUSION: Harmonic® and LigaSure™ are both useful tools in bariatric surgery, and these two advanced power devices are user-friendly and can facilitate surgeon work; from this point of view, the choice of the energy device should be based on the preference of the surgeon and on the hospital costs policy and availability.
format Online
Article
Text
id pubmed-6335858
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-63358582019-02-04 Comparison between LigaSure™ and Harmonic® in Laparoscopic Sleeve Gastrectomy: A Single-Center Experience on 422 Patients Velotti, N. Manigrasso, M. Di Lauro, K. Vitiello, A. Berardi, G. Manzolillo, D. Anoldo, P. Bocchetti, A. Milone, F. Milone, M. De Palma, G. D. Musella, M. J Obes Research Article BACKGROUND: New laparoscopic devices, such as electrothermal bipolar-activated devices (LigaSure™ (LS)) or ultrasonic systems (Harmonic® scalpel (HS)), have been applied recently to bariatric surgery allowing to reduce blood loss and surgical risks. The aim of this study was to retrospectively compare intraoperative performance of HS and LS, postoperative results, and clinical outcomes in a large cohort of patients undergoing LSG. METHODS: Data from 422 morbidly obese patients undergoing LSG in our Bariatric Unit at the Advanced Biomedical Sciences Department of the “Federico II” University of Naples (Italy) between January 2009 and December 2017 were retrospectively analyzed. Subjects were divided into two groups (HS and LS), and operative time, intraoperative complications, and postoperative (within 30 days from surgery) complications were compared. Bleeding from the omentum or from the staple line, use of hemostatic clips, and absorbable hemostat were recorded as intraoperative complications; hemorrhages, abscess formation, gastric leaks, fever, and mortality were considered as postoperative complications. RESULTS: Statistical analysis showed no difference in terms of baseline demographics between the two cohorts. Operative time (48 ± 9 vs 49 ± 6 min, p=0.646) and the rates of intraoperative and postoperative complications did not significantly differ between groups. CONCLUSION: Harmonic® and LigaSure™ are both useful tools in bariatric surgery, and these two advanced power devices are user-friendly and can facilitate surgeon work; from this point of view, the choice of the energy device should be based on the preference of the surgeon and on the hospital costs policy and availability. Hindawi 2019-01-03 /pmc/articles/PMC6335858/ /pubmed/30719344 http://dx.doi.org/10.1155/2019/3402137 Text en Copyright © 2019 N. Velotti et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Velotti, N.
Manigrasso, M.
Di Lauro, K.
Vitiello, A.
Berardi, G.
Manzolillo, D.
Anoldo, P.
Bocchetti, A.
Milone, F.
Milone, M.
De Palma, G. D.
Musella, M.
Comparison between LigaSure™ and Harmonic® in Laparoscopic Sleeve Gastrectomy: A Single-Center Experience on 422 Patients
title Comparison between LigaSure™ and Harmonic® in Laparoscopic Sleeve Gastrectomy: A Single-Center Experience on 422 Patients
title_full Comparison between LigaSure™ and Harmonic® in Laparoscopic Sleeve Gastrectomy: A Single-Center Experience on 422 Patients
title_fullStr Comparison between LigaSure™ and Harmonic® in Laparoscopic Sleeve Gastrectomy: A Single-Center Experience on 422 Patients
title_full_unstemmed Comparison between LigaSure™ and Harmonic® in Laparoscopic Sleeve Gastrectomy: A Single-Center Experience on 422 Patients
title_short Comparison between LigaSure™ and Harmonic® in Laparoscopic Sleeve Gastrectomy: A Single-Center Experience on 422 Patients
title_sort comparison between ligasure™ and harmonic® in laparoscopic sleeve gastrectomy: a single-center experience on 422 patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6335858/
https://www.ncbi.nlm.nih.gov/pubmed/30719344
http://dx.doi.org/10.1155/2019/3402137
work_keys_str_mv AT velottin comparisonbetweenligasureandharmonicinlaparoscopicsleevegastrectomyasinglecenterexperienceon422patients
AT manigrassom comparisonbetweenligasureandharmonicinlaparoscopicsleevegastrectomyasinglecenterexperienceon422patients
AT dilaurok comparisonbetweenligasureandharmonicinlaparoscopicsleevegastrectomyasinglecenterexperienceon422patients
AT vitielloa comparisonbetweenligasureandharmonicinlaparoscopicsleevegastrectomyasinglecenterexperienceon422patients
AT berardig comparisonbetweenligasureandharmonicinlaparoscopicsleevegastrectomyasinglecenterexperienceon422patients
AT manzolillod comparisonbetweenligasureandharmonicinlaparoscopicsleevegastrectomyasinglecenterexperienceon422patients
AT anoldop comparisonbetweenligasureandharmonicinlaparoscopicsleevegastrectomyasinglecenterexperienceon422patients
AT bocchettia comparisonbetweenligasureandharmonicinlaparoscopicsleevegastrectomyasinglecenterexperienceon422patients
AT milonef comparisonbetweenligasureandharmonicinlaparoscopicsleevegastrectomyasinglecenterexperienceon422patients
AT milonem comparisonbetweenligasureandharmonicinlaparoscopicsleevegastrectomyasinglecenterexperienceon422patients
AT depalmagd comparisonbetweenligasureandharmonicinlaparoscopicsleevegastrectomyasinglecenterexperienceon422patients
AT musellam comparisonbetweenligasureandharmonicinlaparoscopicsleevegastrectomyasinglecenterexperienceon422patients