Cargando…

Cost-effectiveness of sensor-augmented insulin pump therapy vs continuous subcutaneous insulin infusion in patients with type 1 diabetes in the Netherlands

AIM: The aim of this study was to perform a cost-effectiveness analysis to establish the cost-effectiveness of sensor-augmented pump therapy (SAP) with automated insulin suspension vs continuous subcutaneous insulin infusion (CSII) alone in patients with type 1 diabetes in the Netherlands. PATIENTS...

Descripción completa

Detalles Bibliográficos
Autores principales: Roze, Stephané, Smith-Palmer, Jayne, de Portu, Simona, Delbaere, Alexis, de Brouwer, Bonnie, de Valk, Harold W
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6336135/
https://www.ncbi.nlm.nih.gov/pubmed/30679914
http://dx.doi.org/10.2147/CEOR.S186298
_version_ 1783388011957846016
author Roze, Stephané
Smith-Palmer, Jayne
de Portu, Simona
Delbaere, Alexis
de Brouwer, Bonnie
de Valk, Harold W
author_facet Roze, Stephané
Smith-Palmer, Jayne
de Portu, Simona
Delbaere, Alexis
de Brouwer, Bonnie
de Valk, Harold W
author_sort Roze, Stephané
collection PubMed
description AIM: The aim of this study was to perform a cost-effectiveness analysis to establish the cost-effectiveness of sensor-augmented pump therapy (SAP) with automated insulin suspension vs continuous subcutaneous insulin infusion (CSII) alone in patients with type 1 diabetes in the Netherlands. PATIENTS AND METHODS: The analysis was performed using the IQVIA CORE Diabetes Model (CDM) in two different patient cohorts: one with suboptimal glycemic control at baseline (mean age 27 years, mean baseline HbA1c 8.0% [64 mmol/mol]) and the other at increased risk of hypoglycemic events (mean age 18.6 years, mean baseline HbA1c 7.5% [58 mmol/mol]). Clinical input data were sourced from published literature, and the analysis was performed from the societal perspective. RESULTS: In patients with suboptimal baseline glycemic control, SAP improved quality-adjusted life expectancy by 1.77 quality-adjusted life years (QALYs) vs CSII (15.54 QALYs vs 13.77 QALYs) with higher lifetime costs (EUR 189,855 vs EUR 150,366), resulting in an incremental cost-effectiveness ratio (ICER) of EUR 22,325 per QALY gained. In this cohort, sensitivity analyses showed that the influence of SAP on fear of hypoglycemia (FoH) and baseline HbA1c were key drivers of results. In patients at increased risk of hypoglycemia, the gain in quality-adjusted life expectancy with SAP vs CSII was 2.16 QALYs (16.70 QALYs vs 14.53 QALYs) with higher lifetime costs (EUR 204,013 vs EUR 171,032) leading to an ICER of EUR 15,243 per QALY gained. In this patient group, findings were most sensitive to changes in assumptions relating to the incidence of severe hypoglycemic events in the CSII arm. CONCLUSION: For type 1 diabetes patients in the Netherlands who do not achieve target HbA1c levels or who experience frequent severe hypoglycemic events on CSII, switching to SAP is likely to be cost-effective.
format Online
Article
Text
id pubmed-6336135
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-63361352019-01-24 Cost-effectiveness of sensor-augmented insulin pump therapy vs continuous subcutaneous insulin infusion in patients with type 1 diabetes in the Netherlands Roze, Stephané Smith-Palmer, Jayne de Portu, Simona Delbaere, Alexis de Brouwer, Bonnie de Valk, Harold W Clinicoecon Outcomes Res Original Research AIM: The aim of this study was to perform a cost-effectiveness analysis to establish the cost-effectiveness of sensor-augmented pump therapy (SAP) with automated insulin suspension vs continuous subcutaneous insulin infusion (CSII) alone in patients with type 1 diabetes in the Netherlands. PATIENTS AND METHODS: The analysis was performed using the IQVIA CORE Diabetes Model (CDM) in two different patient cohorts: one with suboptimal glycemic control at baseline (mean age 27 years, mean baseline HbA1c 8.0% [64 mmol/mol]) and the other at increased risk of hypoglycemic events (mean age 18.6 years, mean baseline HbA1c 7.5% [58 mmol/mol]). Clinical input data were sourced from published literature, and the analysis was performed from the societal perspective. RESULTS: In patients with suboptimal baseline glycemic control, SAP improved quality-adjusted life expectancy by 1.77 quality-adjusted life years (QALYs) vs CSII (15.54 QALYs vs 13.77 QALYs) with higher lifetime costs (EUR 189,855 vs EUR 150,366), resulting in an incremental cost-effectiveness ratio (ICER) of EUR 22,325 per QALY gained. In this cohort, sensitivity analyses showed that the influence of SAP on fear of hypoglycemia (FoH) and baseline HbA1c were key drivers of results. In patients at increased risk of hypoglycemia, the gain in quality-adjusted life expectancy with SAP vs CSII was 2.16 QALYs (16.70 QALYs vs 14.53 QALYs) with higher lifetime costs (EUR 204,013 vs EUR 171,032) leading to an ICER of EUR 15,243 per QALY gained. In this patient group, findings were most sensitive to changes in assumptions relating to the incidence of severe hypoglycemic events in the CSII arm. CONCLUSION: For type 1 diabetes patients in the Netherlands who do not achieve target HbA1c levels or who experience frequent severe hypoglycemic events on CSII, switching to SAP is likely to be cost-effective. Dove Medical Press 2019-01-14 /pmc/articles/PMC6336135/ /pubmed/30679914 http://dx.doi.org/10.2147/CEOR.S186298 Text en © 2019 Roze et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Roze, Stephané
Smith-Palmer, Jayne
de Portu, Simona
Delbaere, Alexis
de Brouwer, Bonnie
de Valk, Harold W
Cost-effectiveness of sensor-augmented insulin pump therapy vs continuous subcutaneous insulin infusion in patients with type 1 diabetes in the Netherlands
title Cost-effectiveness of sensor-augmented insulin pump therapy vs continuous subcutaneous insulin infusion in patients with type 1 diabetes in the Netherlands
title_full Cost-effectiveness of sensor-augmented insulin pump therapy vs continuous subcutaneous insulin infusion in patients with type 1 diabetes in the Netherlands
title_fullStr Cost-effectiveness of sensor-augmented insulin pump therapy vs continuous subcutaneous insulin infusion in patients with type 1 diabetes in the Netherlands
title_full_unstemmed Cost-effectiveness of sensor-augmented insulin pump therapy vs continuous subcutaneous insulin infusion in patients with type 1 diabetes in the Netherlands
title_short Cost-effectiveness of sensor-augmented insulin pump therapy vs continuous subcutaneous insulin infusion in patients with type 1 diabetes in the Netherlands
title_sort cost-effectiveness of sensor-augmented insulin pump therapy vs continuous subcutaneous insulin infusion in patients with type 1 diabetes in the netherlands
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6336135/
https://www.ncbi.nlm.nih.gov/pubmed/30679914
http://dx.doi.org/10.2147/CEOR.S186298
work_keys_str_mv AT rozestephane costeffectivenessofsensoraugmentedinsulinpumptherapyvscontinuoussubcutaneousinsulininfusioninpatientswithtype1diabetesinthenetherlands
AT smithpalmerjayne costeffectivenessofsensoraugmentedinsulinpumptherapyvscontinuoussubcutaneousinsulininfusioninpatientswithtype1diabetesinthenetherlands
AT deportusimona costeffectivenessofsensoraugmentedinsulinpumptherapyvscontinuoussubcutaneousinsulininfusioninpatientswithtype1diabetesinthenetherlands
AT delbaerealexis costeffectivenessofsensoraugmentedinsulinpumptherapyvscontinuoussubcutaneousinsulininfusioninpatientswithtype1diabetesinthenetherlands
AT debrouwerbonnie costeffectivenessofsensoraugmentedinsulinpumptherapyvscontinuoussubcutaneousinsulininfusioninpatientswithtype1diabetesinthenetherlands
AT devalkharoldw costeffectivenessofsensoraugmentedinsulinpumptherapyvscontinuoussubcutaneousinsulininfusioninpatientswithtype1diabetesinthenetherlands