Cargando…
A novel application of B-ultrasonography at various head positions in the diagnosis of untypical uveitis-glaucoma-hyphema (UGH) syndrome: A case report
RATIONALE: Uveitis-glaucoma-hyphema (UGH) syndrome could be identified by conventional ultrasound biomicroscopy (UBM) and B-ultrasonography, but failed in some untypical cases. We introduced a novel application of B-ultrasonography in diagnosis of UGH syndrome in a rare case. PATIENT CONCERNS: A 60-...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6336659/ https://www.ncbi.nlm.nih.gov/pubmed/30633162 http://dx.doi.org/10.1097/MD.0000000000013891 |
_version_ | 1783388089248382976 |
---|---|
author | Wu, Nianlang Zhang, Huicheng Chen, Bin Ding, Wenting |
author_facet | Wu, Nianlang Zhang, Huicheng Chen, Bin Ding, Wenting |
author_sort | Wu, Nianlang |
collection | PubMed |
description | RATIONALE: Uveitis-glaucoma-hyphema (UGH) syndrome could be identified by conventional ultrasound biomicroscopy (UBM) and B-ultrasonography, but failed in some untypical cases. We introduced a novel application of B-ultrasonography in diagnosis of UGH syndrome in a rare case. PATIENT CONCERNS: A 60-year-old woman was referred for distending pain with blurred vision for more than 1 month in the right eye after cataract surgery. DIAGNOSES: B-ultrasound scanner and UBM demonstrated the Intraocular Lens (IOL) was centered in the bag. No chafing in all directions was detected between IOL and iris/ciliary body. The proposed diagnoses were iridocyclitis and secondary glaucoma of the right eye. INTERVENTIONS: The symptoms were not improved after antiinflammation and intraocular pressure (IOP) lowering treatment for 1 month. B-ultrasonography was applied in horizontal, sitting, and head-down positions. The results demonstrated movements of IOLs when position changed. The IOLs were in contact with the iris pigment epithelium in sitting position and head-down positions but not in horizontal position. The dynamic interactions between IOLs and iris/ciliary body implied a diagnosis of UGH syndrome. The IOLs were then extracted. OUTCOMES: Two weeks after the IOLs explantation, the IOP significantly reduced to a normal level in both eyes. Ten-month follow-up showed that the IOP was maintained at a normal level. LESSONS: The chronically intermittent chafing between IOL and iris in specific head positions would also lead to UGH syndrome. Dynamic application of B-ultrasonography in various head positions could be useful in the diagnosis of an untypical UGH syndrome. |
format | Online Article Text |
id | pubmed-6336659 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-63366592019-01-24 A novel application of B-ultrasonography at various head positions in the diagnosis of untypical uveitis-glaucoma-hyphema (UGH) syndrome: A case report Wu, Nianlang Zhang, Huicheng Chen, Bin Ding, Wenting Medicine (Baltimore) Research Article RATIONALE: Uveitis-glaucoma-hyphema (UGH) syndrome could be identified by conventional ultrasound biomicroscopy (UBM) and B-ultrasonography, but failed in some untypical cases. We introduced a novel application of B-ultrasonography in diagnosis of UGH syndrome in a rare case. PATIENT CONCERNS: A 60-year-old woman was referred for distending pain with blurred vision for more than 1 month in the right eye after cataract surgery. DIAGNOSES: B-ultrasound scanner and UBM demonstrated the Intraocular Lens (IOL) was centered in the bag. No chafing in all directions was detected between IOL and iris/ciliary body. The proposed diagnoses were iridocyclitis and secondary glaucoma of the right eye. INTERVENTIONS: The symptoms were not improved after antiinflammation and intraocular pressure (IOP) lowering treatment for 1 month. B-ultrasonography was applied in horizontal, sitting, and head-down positions. The results demonstrated movements of IOLs when position changed. The IOLs were in contact with the iris pigment epithelium in sitting position and head-down positions but not in horizontal position. The dynamic interactions between IOLs and iris/ciliary body implied a diagnosis of UGH syndrome. The IOLs were then extracted. OUTCOMES: Two weeks after the IOLs explantation, the IOP significantly reduced to a normal level in both eyes. Ten-month follow-up showed that the IOP was maintained at a normal level. LESSONS: The chronically intermittent chafing between IOL and iris in specific head positions would also lead to UGH syndrome. Dynamic application of B-ultrasonography in various head positions could be useful in the diagnosis of an untypical UGH syndrome. Wolters Kluwer Health 2019-01-11 /pmc/articles/PMC6336659/ /pubmed/30633162 http://dx.doi.org/10.1097/MD.0000000000013891 Text en Copyright © 2019 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0 |
spellingShingle | Research Article Wu, Nianlang Zhang, Huicheng Chen, Bin Ding, Wenting A novel application of B-ultrasonography at various head positions in the diagnosis of untypical uveitis-glaucoma-hyphema (UGH) syndrome: A case report |
title | A novel application of B-ultrasonography at various head positions in the diagnosis of untypical uveitis-glaucoma-hyphema (UGH) syndrome: A case report |
title_full | A novel application of B-ultrasonography at various head positions in the diagnosis of untypical uveitis-glaucoma-hyphema (UGH) syndrome: A case report |
title_fullStr | A novel application of B-ultrasonography at various head positions in the diagnosis of untypical uveitis-glaucoma-hyphema (UGH) syndrome: A case report |
title_full_unstemmed | A novel application of B-ultrasonography at various head positions in the diagnosis of untypical uveitis-glaucoma-hyphema (UGH) syndrome: A case report |
title_short | A novel application of B-ultrasonography at various head positions in the diagnosis of untypical uveitis-glaucoma-hyphema (UGH) syndrome: A case report |
title_sort | novel application of b-ultrasonography at various head positions in the diagnosis of untypical uveitis-glaucoma-hyphema (ugh) syndrome: a case report |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6336659/ https://www.ncbi.nlm.nih.gov/pubmed/30633162 http://dx.doi.org/10.1097/MD.0000000000013891 |
work_keys_str_mv | AT wunianlang anovelapplicationofbultrasonographyatvariousheadpositionsinthediagnosisofuntypicaluveitisglaucomahyphemaughsyndromeacasereport AT zhanghuicheng anovelapplicationofbultrasonographyatvariousheadpositionsinthediagnosisofuntypicaluveitisglaucomahyphemaughsyndromeacasereport AT chenbin anovelapplicationofbultrasonographyatvariousheadpositionsinthediagnosisofuntypicaluveitisglaucomahyphemaughsyndromeacasereport AT dingwenting anovelapplicationofbultrasonographyatvariousheadpositionsinthediagnosisofuntypicaluveitisglaucomahyphemaughsyndromeacasereport AT wunianlang novelapplicationofbultrasonographyatvariousheadpositionsinthediagnosisofuntypicaluveitisglaucomahyphemaughsyndromeacasereport AT zhanghuicheng novelapplicationofbultrasonographyatvariousheadpositionsinthediagnosisofuntypicaluveitisglaucomahyphemaughsyndromeacasereport AT chenbin novelapplicationofbultrasonographyatvariousheadpositionsinthediagnosisofuntypicaluveitisglaucomahyphemaughsyndromeacasereport AT dingwenting novelapplicationofbultrasonographyatvariousheadpositionsinthediagnosisofuntypicaluveitisglaucomahyphemaughsyndromeacasereport |